Particle Imaging Velocimetry Evaluation of Intracranial Stents in Sidewall Aneurysm: Hemodynamic Transition Related to the Stent Design

被引:57
作者
Bouillot, Pierre [1 ,2 ]
Brina, Olivier [1 ]
Ouared, Rafik [1 ]
Lovblad, Karl-Olof [1 ]
Farhat, Mohamed [2 ]
Pereira, Vitor Mendes [1 ,3 ,4 ]
机构
[1] Univ Hosp Geneva, Serv Neuroradiol, Intervent Neuroradiol Unit, Geneva, Switzerland
[2] Ecole Polytech Fed Lausanne, Lab Hydraul Machines, Lausanne, Switzerland
[3] Toronto Western Hosp, Univ Hlth Network, Dept Med Imaging, Div Neuroradiol, Toronto, ON M5T 2S8, Canada
[4] Toronto Western Hosp, Univ Hlth Network, Dept Surg, Div Neurosurg, Toronto, ON M5T 2S8, Canada
基金
瑞士国家科学基金会;
关键词
CEREBRAL ANEURYSMS; IN-VITRO; PULSATILE FLOWS; PARENT VESSEL; BLOOD-FLOW; MODEL; PLACEMENT; STRAIGHT; STEADY; THROMBOSIS;
D O I
10.1371/journal.pone.0113762
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We investigated the flow modifications induced by a large panel of commercial-off-the-shelf (COTS) intracranial stents in an idealized sidewall intracranial aneurysm (IA). Flow velocities in IA silicone model were assessed with and without stent implantation using particle imaging velocimetry (PIV). The use of the recently developed multi-time-lag method has allowed for uniform and precise measurements of both high and low velocities at IA neck and dome, respectively. Flow modification analysis of both regular (RSs) and flow diverter stents (FDSs) was subsequently correlated with relevant geometrical stent parameters. Flow reduction was found to be highly sensitive to stent porosity variations for regular stents RSs and moderately sensitive for FDSs. Consequently, two distinct IA flow change trends, with velocity reductions up to 50% and 90%, were identified for high-porosity RS and low-porosity FDS, respectively. The intermediate porosity (88%) regular braided stent provided the limit at which the transition in flow change trend occurred with a flow reduction of 84%. This transition occurred with decreasing stent porosity, as the driving force in IA neck changed from shear stress to differential pressure. Therefore, these results suggest that stents with intermediate porosities could possibly provide similar flow change patterns to FDS, favourable to curative thrombogenesis in IAs.
引用
收藏
页数:17
相关论文
共 47 条
[1]   Modeling of flow in a straight stented and nonstented side wall aneurysm model [J].
Aenis, M ;
Stancampiano, AP ;
Wakhloo, AK ;
Lieber, BB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (02) :206-212
[2]   Methodologies to assess blood flow in cerebral aneurysms: Current state of research and perspectives [J].
Augsburger, L. ;
Reymond, P. ;
Fonck, E. ;
Kulcsar, Z. ;
Farhat, M. ;
Ohta, M. ;
Stergiopulos, N. ;
Ruefenacht, D. A. .
JOURNAL OF NEURORADIOLOGY, 2009, 36 (05) :270-277
[3]  
Augsburger L, 2009, CLIN NEURORADIOL, V19, P204, DOI 10.1007/s00062-009-9005-0
[4]   An in vitro study of silk stent morphology [J].
Aurboonyawat, Thaweesak ;
Blanc, Raphael ;
Schmidt, Paul ;
Piotin, Michel ;
Spelle, Laurent ;
Nakib, Amir ;
Moret, Jacques .
NEURORADIOLOGY, 2011, 53 (09) :659-667
[5]   Influence of stent configuration on cerebral aneurysm fluid dynamics [J].
Babiker, M. Haithem ;
Gonzalez, L. Fernando ;
Ryan, Justin ;
Albuquerque, Felipe ;
Collins, Daniel ;
Elvikis, Arius ;
Frakes, David H. .
JOURNAL OF BIOMECHANICS, 2012, 45 (03) :440-447
[6]   Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial [J].
Becske, Tibor ;
Kallmes, David F. ;
Saatci, Isil ;
McDougall, Cameron G. ;
Szikora, Istvn ;
Lanzino, Giuseppe ;
Moran, Christopher J. ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Cekirge, Saruhan H. ;
Nelson, Peter K. .
RADIOLOGY, 2013, 267 (03) :858-868
[7]   Multi-time-lag PIV analysis of steady and pulsatile flows in a sidewall aneurysm [J].
Bouillot, P. ;
Brina, O. ;
Ouared, R. ;
Lovblad, K. O. ;
Pereira, V. Mendes ;
Farhat, M. .
EXPERIMENTS IN FLUIDS, 2014, 55 (06)
[8]   Endovascular Treatment of Intracranial Aneurysms With Flow Diverters A Meta-Analysis [J].
Brinjikji, Waleed ;
Murad, Mohammad H. ;
Lanzino, Giuseppe ;
Cloft, Harry J. ;
Kallmes, David F. .
STROKE, 2013, 44 (02) :442-447
[9]   Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms [J].
Cantón, G ;
Levy, DI ;
Lasheras, JC ;
Nelson, PK .
JOURNAL OF NEUROSURGERY, 2005, 103 (05) :891-902
[10]   Hemodynamic changes due to stent placement in bifurcating intracranial aneurysms [J].
Cantón, G ;
Levy, DI ;
Lasheras, JC .
JOURNAL OF NEUROSURGERY, 2005, 103 (01) :146-155