Hybrid screw fixation for femoral neck fractures: Does it prevent mechanical failure?

被引:6
|
作者
Cuellar, Derly O., III [1 ]
Velez, Dencel A. Garcia [1 ]
Bledsoe, Gary [2 ]
Watson, J. Tracy [1 ,3 ]
机构
[1] St Louis Univ, Dept Orthopaed Surg, Sch Med, St Louis, MO 63104 USA
[2] St Louis Univ, Pk Sch Engn, St Louis, MO 63103 USA
[3] St Louis Univ, Dept Orthopaed Surg, 3635 Vista Ave,7th Floor Desloge Towers, St Louis, MO 63110 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2022年 / 53卷 / 08期
关键词
Femoral neck fracture; Hybrid screw; Hybrid screw fixation; Inverted triangle; Fully threaded; Calcar screw; Length stable; THREADED POSITIONING SCREW; CANNULATED SCREWS; VARUS COLLAPSE; HIP; HEMIARTHROPLASTY; STRENGTH; BURDEN;
D O I
10.1016/j.injury.2021.11.022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Traditionally, femoral neck fracture fixation has been performed using three partially threaded cancellous screws. However, fracture collapse with femoral neck shortening, and varus deforma-tion frequently occurs due to posterior medial comminution and lack of calcar support. We hypothesize replacing the inferior neck/calcar screw with a fully threaded, length stable, screw will provide improved biomechanical stability, decrease femoral neck shortening and varus collapse. Methods: Ten matched cadaveric pairs (20 femurs) were randomly assigned to two screw fixation groups. Group 1 (Hybrid) utilized one fully threaded calcar screw & two partially threaded superior screws. Group 2 (PT) utilized all partially threaded screws. Specimens underwent standardized femoral neck os-teotomies, 45 degrees from the horizontal, with 5 mm posteromedial wedge removed to simulate posteromedial comminution. Screws were placed using fluoroscopic guidance. Specimens were biomechanically tested using two loading sequences: 1) Axial load applied up to 700 N, followed by cyclic loading at 2 Hz with loads of 700 to 1,400 N for 10,0 0 0 cycles. 2) All surviving constructs were cyclically loaded to failure in stepwise incremental manner with max load of 4,0 0 0 N. Paired t-tests used to compare stiffness, cycles to failure, and max load to failure (defined as 15 mm load actuator displacement). Results: Construct stiffness was 2848 +/- 344 N/mm in PT vs. 2767 +/- 665 for Hybrid ( P = 0.628). Load to failure demonstrated, hybrid superiority with max cycles to failure (3797 +/- 400 cycles) vs. (2981 +/- 856 cycles in PT) ( p = 0.010), and max load prior to failure (3290 +/- 196 N) vs. (2891 +/- 421 N in PT) ( p = 0.010). No significant difference in bone mineral density was noted in any of the specimens. Conclusions: Our study is the first to assess the biomechanical effects of hybrid fixation for femoral neck fractures. Hybrid screw configuration resulted in significantly stronger constructs, with higher axial load and increased cycles prior to failure. The advantageous mechanical properties demonstrated using a fully threaded inferior calcar screw provides a length stable construct which may prevent the common com-plication of excessive femoral neck shortening, varus collapse and poor functional outcome. (c) 2021 Published by Elsevier Ltd.
引用
收藏
页码:2839 / 2845
页数:7
相关论文
共 50 条
  • [21] High incidence of "in-out-in" posterosuperior screws after cannulated screw fixation of femoral neck fractures
    Yuan, Brandon J.
    Shamaa, Mohamad Tayseer
    Aibinder, William R.
    Parry, Joshua A.
    Cross, William W.
    Barlow, Jonathan D.
    Sems, Stephen A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (08) : 1417 - 1420
  • [22] Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures? A biomechanical analysis in cadaveric bone
    Hawks, Michael A.
    Kim, Hyunchul
    Strauss, Joseph E.
    Oliphant, Bryant W.
    Golden, Robert D.
    Hsieh, Adam H.
    Nascone, Jason W.
    O'Toole, Robert V.
    CLINICAL BIOMECHANICS, 2013, 28 (08) : 886 - 891
  • [23] Biomechanical analysis of the closed reduction internal fixation with cannulated screw of femoral neck fractures
    Wang, Jian-Guang
    Wu, Jun-Xian
    Li, Yu-Min
    Xu, You-Yin
    MEDICINE, 2021, 100 (08) : E24834
  • [24] Biplane double-supported screw fixation (F-technique): a method of screw fixation at osteoporotic fractures of the femoral neck
    Orlin Filipov
    European Journal of Orthopaedic Surgery & Traumatology, 2011, 21 : 539 - 543
  • [25] Incomplete Screw Thread Engagement of Proximal Fragment: A Possible Failure Risk After Internal Fixation for Femoral Neck Fractures
    Tanaka, Atsuki
    Hiranaka, Takafumi
    Fujishiro, Takaaki
    Koide, Motoki
    Suda, Yoshihito
    Saito, Akira
    Arimoto, Akihiko
    Okamoto, Koji
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [26] Factors that influence the complications and outcomes of femoral neck fractures treated by cannulated screw fixation
    Ramadanov, Nikolai
    Toma, Ionel
    Herkner, Harald
    Klein, Roman
    Behringer, Wilhelm
    Matthes, Gerrit
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [27] Cannulated Screw Fixation of Femoral Neck Fractures: An Intraoperative Pearl to Avoid a Common Mistake
    Paziuk, Taylor
    Chang, Gerard
    Krieg, James
    TECHNIQUES IN ORTHOPAEDICS, 2021, 36 (04) : 409 - 411
  • [28] Pre-sliding of the femoral neck system to prevent postoperative shortening of femoral neck fractures
    Lin, Dongze
    Zhu, Fugui
    Chen, Peisheng
    Lin, Chaohui
    Chen, Bin
    Zheng, Ke
    Zheng, Shunze
    Lin, Fengfei
    HELIYON, 2024, 10 (07)
  • [29] Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures
    Wang, Min
    Wang, Yunlong
    Zou, Fa
    Tan, Lin
    Wang, Yunjuan
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [30] Does fully-threaded Headless Compression Screw provide a length-stable fixation in undisplaced femoral neck fractures?
    Chiang, Ming-Hung
    Wang, Chun-Liang
    Fu, Shau-Huai
    Hung, Chih-Chien
    Yang, Rong-Sen
    ASIAN JOURNAL OF SURGERY, 2019, 42 (01) : 320 - 325