A Robust Gesture Recognition Algorithm Based on Surface EMG

被引:0
作者
Lin, Ke [1 ]
Wu, Chaohua [1 ]
Huang, Xiaoshan [1 ]
Ding, Qiang [2 ]
Gao, Xiaorong [1 ]
机构
[1] Tsinghua Univ, Beijing 100084, CO, Peoples R China
[2] Huawei Technol Co Ltd, Beijing 100085, CO, Peoples R China
来源
2015 SEVENTH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTATIONAL INTELLIGENCE (ICACI) | 2015年
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
This study researched a robust gesture recognition algorithm based on EMG. The proposed algorithm only needs very limited training data (1 or 2 training trials for each gesture). The contribution of the proposed algorithm was mainly three-fold. First, a shrinkage approach was applied to estimate the samples' covariance matrix, which helped to improve the robustness of the algorithm. Second, to evaluate the system performance, classification accuracy and gesture number to be recognized was compromised using information transfer rate (ITR). We found a system which can recognize 10 gestures could achieve similar ITR as the system which can recognize 20 gestures. However, the 10-gesture system was more robust. Third, K-L divergence was used to evaluate the separability of the EMG signals from different gestures. The result of a 5 subject experiment showed that the classification accuracy of 10 gestures using 2 trials as training set can reach 85%.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 15 条
  • [1] Ahsan M.R., 2012, INT S MECH ITS APPL, P1, DOI 10.1109/ISMA.2012.6215165
  • [2] Ahsan R, 2009, EUR J SCI RES, V33, P480
  • [3] Cannan J., 2011, Human-machine interaction (hmi): A survey
  • [4] Continuous myoelectric control for powered prostheses using hidden Markov models
    Chan, ADC
    Englehart, KB
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (01) : 121 - 124
  • [5] Chowdhury A., 2013, ICORD 13, P411, DOI DOI 10.1007/978-81-322-1050-4_33
  • [6] A real-time EMG pattern recognition system based on linear-nonlinear feature projection for a multifunction myoelectric hand
    Chu, Jun-Uk
    Moon, Inhyuk
    Mun, Mu-Seong
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (11) : 2232 - 2239
  • [7] Wireless Medical-Embedded Systems: A Review of Signal-Processing Techniques for Classification
    Ghasemzadeh, Hassan
    Ostadabbas, Sarah
    Guenterberg, Eric
    Pantelopoulos, Alexandros
    [J]. IEEE SENSORS JOURNAL, 2013, 13 (02) : 423 - 437
  • [8] Kosmidou Vasiliki E, 2006, Conf Proc IEEE Eng Med Biol Soc, V2006, P6197
  • [9] Brain-computer interface (BCI) operation: optimizing information transfer rates
    McFarland, DJ
    Sarnacki, WA
    Wolpaw, JR
    [J]. BIOLOGICAL PSYCHOLOGY, 2003, 63 (03) : 237 - 251
  • [10] A shrinkage approach to large-scale covariance matrix estimation and implications for functional genomics
    Schäfer, J
    Strimmer, K
    [J]. STATISTICAL APPLICATIONS IN GENETICS AND MOLECULAR BIOLOGY, 2005, 4 : 1 - 30