Athroscopically controlled minimally invasive osteosynthesis of scaphoid fractures.: A pilot study

被引:0
作者
Böhringer, G [1 ]
Schädel-Höpfner, M [1 ]
Lemke, T [1 ]
Gotzen, L [1 ]
机构
[1] Univ Marburg, Unfallchirurg Klin, Marburg, Germany
来源
UNFALLCHIRURG | 2000年 / 103卷 / 12期
关键词
scaphoidfracture; arthroscopy; minimally invasive osteosynthesis; SL instability; TFC complex;
D O I
10.1007/s001130050673
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We could not find any systematic studies about the value of arthroscopy in scaphoid fractures in the literature, and therefore undertook a pilot study of 20 scaphoid fractures which were treated arthroscopically by the Herbert-Whipple screw and were minimally invasive. We found very good radiological and clinical results in 17 patients and good results in 3 patients evaluated by the Wozasek and Moser score. For reduction of dislocated fractures we used distraction with 5 kg in the wine waiters position. In four cases we used additional K wires as joysticks. Arthroscopy is less valuable in reduction, however, it is important in verification of the compression force of the Herbert-Whipple screw and for diagnosis and therapy of lesions of the scapholunate ligament and TFC complex. We found seven SL instabilities, two lesions of the meniscus,and one Palmer 1B lesion of the TFC complex. From these results we conclude that arthroscopy should necessarily be done by minimally invasive osteosynthesis of scaphoid fractures to detect and treat discoligamentous injuries of the wrist.
引用
收藏
页码:1086 / 1092
页数:7
相关论文
共 18 条
  • [1] BLACK DM, 1987, CLIN ORTHOP RELAT R, P205
  • [2] The use of the Herbert bone screw by the freehand-method for osteosynthesis scaphoid fracture
    Brauer, RB
    Dierking, M
    Werber, KD
    [J]. UNFALLCHIRURG, 1997, 100 (10): : 776 - 781
  • [3] Herbert screw fixation of scaphoid fractures
    Filan, SL
    Herbert, TJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (04): : 519 - 529
  • [4] Acute percutaneous scaphoid fixation - A pilot study
    Haddad, FS
    Goddard, NJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (01): : 95 - 99
  • [5] MANAGEMENT OF THE FRACTURED SCAPHOID USING A NEW BONE SCREW
    HERBERT, TJ
    FISHER, WE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (01): : 114 - 123
  • [6] Herbert screw fixation by limited access for acute fractures of the scaphoid
    Inoue, G
    Shionoya, K
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03): : 418 - 421
  • [7] Jennings J E, 1985, Arthroscopy, V1, P160, DOI 10.1016/S0749-8063(85)80003-7
  • [8] KING RJ, 1982, J ROY SOC MED, V75, P860
  • [9] SCAPHOID NONUNION WITH DISI DEFORMITY - A SURVEY OF CLINICAL CASES WITH SPECIAL REFERENCE TO LIGAMENTOUS INJURY
    NAKAMURA, R
    IMAEDA, T
    TSUGE, S
    WATANABE, K
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1991, 16B (02) : 156 - 161
  • [10] Mechanical strength of scaphoid fixation
    Newport, ML
    Williams, CD
    Bradley, WD
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1996, 21B (01) : 99 - 102