Numerical and experimental validation study of flame extent of a pool fire under the ceiling

被引:29
作者
Wang, Yongdong [1 ,2 ,3 ]
Vouros, Alexandros [4 ]
Zhang, Jianping [2 ,3 ]
Delichatsios, Michael A. [2 ,3 ]
机构
[1] Changan Univ, Sch Highway, Xian 710064, Shaanxi, Peoples R China
[2] Ulster Univ, FireSERT, Sch Built Environm, Newtownabbey BT37 0QB, North Ireland
[3] Ulster Univ, Built Environm Res Inst, Newtownabbey BT37 0QB, North Ireland
[4] Univ Patras, Dept Civil Engn, Patras 26504, Greece
关键词
Pool fire; Ceiling; Flame extent; FDS; Stoichiometric mixture fraction; LENGTHS; PLUMES; JETS;
D O I
10.1016/j.jlp.2017.04.029
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The purpose of this work is to establish dimensionless correlations for the flame extent under a ceiling that can be used for large-scale calculations of radiative heat fluxes for which numerical simulations may be prohibitive. Towards this objective, this paper presents a numerical study of the flame height in an open pool fire and the subsequent flame extent under the ceiling. The stoichiometric mixture fraction is used to define the continuous flame height which also coincides with the maximum mean temperature along the centerline of the fire. The size of the pool fire is 0.1 m x 0.1 m having heat release rates (HRRs) from 2 to 100 kW for two ceiling heights of 30 and 50 cm. The predicted free flame height and horizontal flame extent are compared to existing correlations and experimental data in the literature. It is found that the predicted continuous flame height is about three fifths that of the experimental mean flame height reported in the literature. The predicted horizontal flame extent also agrees well with existing experimental correlations, although some difference may indicate that the relation between the mean and continuous flame heights derived for an open free pool fire may no longer apply due to the presence of the ceiling which affects air entrainment and the turbulence of the ceiling flame jet. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:652 / 659
页数:8
相关论文
共 16 条
[1]   FLAME LENGTHS UNDER CEILINGS [J].
BABRAUSKAS, V .
FIRE AND MATERIALS, 1980, 4 (03) :119-126
[2]   FIRE PLUMES AND CEILING JETS [J].
BEYLER, CL .
FIRE SAFETY JOURNAL, 1986, 11 (1-2) :53-75
[3]   An integral model for turbulent flame radial lengths under a ceiling [J].
Ding, Haiwen ;
Quintiere, James G. .
FIRE SAFETY JOURNAL, 2012, 52 :25-33
[4]  
Drysdale D, 2011, INTRO FIRE DYNAMICS
[5]   An investigation of the detailed flame shape and flame length under the ceiling of a channel [J].
Gao, Zihe ;
Ji, Jie ;
Wan, Huaxian ;
Li, Kaiyuan ;
Sun, Jinhua .
PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2015, 35 :2657-2664
[6]   MEASUREMENT OF FLAME LENGTHS UNDER CEILINGS [J].
GROSS, D .
FIRE SAFETY JOURNAL, 1989, 15 (01) :31-44
[7]  
Hasemi Y., 1984, FIRE SCI TECHNOLOGY, V4, P15, DOI [10.3210/fst.4.15, DOI 10.3210/FST.4.15]
[8]   CEILING JETS OF STRONG FIRE PLUMES [J].
HESKESTAD, G ;
HAMADA, T .
FIRE SAFETY JOURNAL, 1993, 21 (01) :69-82
[9]   LUMINOUS HEIGHTS OF TURBULENT-DIFFUSION FLAMES [J].
HESKESTAD, G .
FIRE SAFETY JOURNAL, 1983, 5 (02) :103-108
[10]  
Karlsson J., 1999, ENCLOSURE FIRE DYNAM