Effect of Active Damping on Output Impedance of Three-Phase Grid-Connected Converter

被引:51
作者
Aapro, Aapo [1 ]
Messo, Tuomas [1 ]
Roinila, Tomi [2 ]
Suntio, Teuvo [1 ]
机构
[1] Tampere Univ Technol, Dept Elect Engn, Tampere 33720, Finland
[2] Tampere Univ Technol, Dept Automat Sci & Engn, Tampere 33720, Finland
关键词
Active damping (AD); control design; impedance modeling; power system stability; LCL-FILTER; VOLTAGE-SOURCE; DESIGN; RESONANCE; STABILITY; INVERTER; DELAY; VSCS;
D O I
10.1109/TIE.2017.2696494
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
LCL-filter is commonly used to attenuate the switching harmonics of grid-connected converters. LCL-filter creates resonances in the converter dynamics which shall be damped for ensuring robust performance of the converter. Active damping methods can be used to attenuate the resonant behavior effectively. Accordingly, the output impedance is affected and the grid-interaction sensitivity of the converter varies with the active damping design. In order to carry out impedance-based stability analysis or assessment of the harmonic rejection capability, an accurate analytical model to predict the output impedance is necessary. This paper investigates the output impedance properties of capacitor-current-feedback active damping, which are so far not considered thoroughly in the literature. The output impedance modification with the active damping design is explained, thus, the stability and harmonic rejection capability of the converter can be improved. Furthermore, in order to validate the model, experimental measurements of the output impedance with active damping are presented for the first time in the literature.
引用
收藏
页码:7532 / 7541
页数:10
相关论文
共 36 条
[1]  
Aapro A, 2015, 2015 9TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE-ECCE ASIA), P2267, DOI 10.1109/ICPE.2015.7168092
[2]  
[Anonymous], IEEE 16 WORKSH CONTR
[3]   A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter [J].
Blasko, V ;
Kaura, V .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (02) :542-550
[4]  
Buso S., 2006, Digital Control in Power Electronics, DOI [DOI 10.2200/S00047ED1V01Y200609PEL002, 10.2200/S00047ED1V01Y200609PEL002.]
[5]   Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters [J].
Cespedes, Mauricio ;
Sun, Jian .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1254-1261
[6]   Impedance-Phased Dynamic Control Method for Grid-Connected Inverters in a Weak Grid [J].
Chen, Xin ;
Zhang, Yang ;
Wang, Shanshan ;
Chen, Jie ;
Gong, Chunying .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (01) :274-283
[7]  
Cvetkovic I, 2011, IEEE ENER CONV, P791, DOI 10.1109/ECCE.2011.6063851
[8]  
Dahono P. A., 2001, 4th IEEE International Conference on Power Electronics and Drive Systems. IEEE PEDS 2001 - Indonesia. Proceedings (Cat. No.01TH8594), P403, DOI 10.1109/PEDS.2001.975347
[9]   Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters [J].
Dannehl, Joerg ;
Fuchs, Friedrich Wilhelm ;
Hansen, Steffan ;
Thogersen, Paul Bach .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (04) :1509-1517
[10]   Passivity-Based Stability Assessment of Grid-Connected VSCs-An Overview [J].
Harnefors, Lennart ;
Wang, Xiongfei ;
Yepes, Alejandro G. ;
Blaabjerg, Frede .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2016, 4 (01) :116-125