From data to diagnosis and control using generalized orthonormal basis filters. Part II: Model predictive and fault tolerant control

被引:48
作者
Patwardhan, SC
Manuja, S
Narasimhan, S
Shah, SL [1 ]
机构
[1] Univ Alberta, Dept Chem & Mat Engn, Edmonton, AB T6G 2G6, Canada
[2] Indian Inst Technol, Dept Chem Engn, Bombay 400076, Maharashtra, India
[3] Indian Inst Technol, Dept Chem Engn, Madras 600036, Tamil Nadu, India
基金
加拿大自然科学与工程研究理事会;
关键词
innovations form of state space model; model predictive control; unmeasured disturbances; regulatory performance; likelihood ratio method; fault tolerant control;
D O I
10.1016/j.jprocont.2005.04.011
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Given a state space model together with the state noise and measurement noise characteristics, there are well established procedures to design a Kalman filter based model predictive control (MPC) and fault diagnosis scheme. In practice, however, such disturbance models relating the true root cause of the unmeasured disturbances with the states/outputs are difficult to develop. To alleviate this difficulty, we reformulate the MPC scheme proposed by K.R. Muske and J.B. Rawlings [Model predictive control with linear models, AIChE J. 39 (1993) 262-287] and the fault tolerant control scheme (FTCS) proposed by J. Prakash, S.C. Patwardhan, and S. Narasimhan (A supervisory approach to fault tolerant control of linear multivariable systems, Ind. Eng. Chem. Res. 41 (2002) 2270-2281) starting from the innovations form of state space model identified using generalized orthonormal basis function (GOBF) parameterization. The efficacy of the proposed MPC scheme and the on-line FTCS is demonstrated by conducting simulation studies on the benchmark shell control problem (SCP) and experimental studies on a laboratory scale continuous stirred tank heater (CSTH) system. The analysis of the simulation and experimental results reveals that the MPC scheme formulated using the identified observers produces superior regulatory performance when compared to the regulatory performance of conventional MPC controller even in the presence of significant plant model mismatch. The FTCS reformulated using the innovations form of state space model is able to isolate sensor as well as actuator faults occurring sequentially in time. In particular, the proposed FTCS is able to eliminate offset between the true value of the measured variable and the setpoint in the presence of sensor biases. Thus, the simulation and experimental study clearly demonstrate the advantages of formulating MPC and generalized likelihood ratio (GLR) based fault diagnosis schemes using the innovations form of state space model identified from input output data. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:157 / 175
页数:19
相关论文
共 26 条
[1]  
ASTROM K, 1994, COMPUTER CONTROLLED
[2]  
Chen J., 2012, Robust model-based fault diagnosis for dynamic systems, VVol. 3
[3]   GENERALIZED PREDICTIVE CONTROL .1. THE BASIC ALGORITHM [J].
CLARKE, DW ;
MOHTADI, C ;
TUFFS, PS .
AUTOMATICA, 1987, 23 (02) :137-148
[4]   FAULT-DIAGNOSIS IN DYNAMIC-SYSTEMS USING ANALYTICAL AND KNOWLEDGE-BASED REDUNDANCY - A SURVEY AND SOME NEW RESULTS [J].
FRANK, PM .
AUTOMATICA, 1990, 26 (03) :459-474
[5]   MODEL PREDICTIVE CONTROL - THEORY AND PRACTICE - A SURVEY [J].
GARCIA, CE ;
PRETT, DM ;
MORARI, M .
AUTOMATICA, 1989, 25 (03) :335-348
[6]  
KARTHIK R, 2000, AICHE NAT M LOS ANG
[7]  
LEE JH, 1996, CACHE AICHE S SERIES, V316, P201
[8]  
Ljung L., 1987, System Identification: Theory for the User. Bibliyografya ve .Indeks
[9]  
MANUJA S, 2004, THESIS INDIAN I TECH
[10]  
MANUJA S, 2003, P INT S PROC SYST EN, P157