Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method

被引:329
作者
Gesche, Heiko [1 ]
Grosskurth, Detlef [2 ]
Kuechler, Gert [3 ]
Patzak, Andreas [1 ]
机构
[1] Charite Univ Med Berlin, Inst Vegetat Physiol, D-10117 Berlin, Germany
[2] Clin Rehabil Mettnau, Radolfzell am Bodensee, Germany
[3] SOMNOmed GmbH, Randersacker, Germany
关键词
Blood pressure; Pulse transit time; Exercise; WAVE VELOCITY; ARRIVAL-TIME; FINGER; WOMEN; EXERCISE; MARKER; ECG;
D O I
10.1007/s00421-011-1983-3
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Pulse transit time (PTT) and pulse wave velocity (PWV), respectively, were shown to have a correlation with systolic blood pressure (SBP) and have been reported to be suitable for indirect BP measurements. The aim of this study was to create a function between SBP and PWV, and to test its reliability for the determination of absolute SBP using a non-linear algorithm and a one-point calibration. 63 volunteers performed exercise to induce rises in BP. Arterial PTT was measured between the R-spike of the ECG and the plethysmographic curve of finger pulse-oximetry. The reference BP was measured using a cuff-based sphygmomanometric aneroid device. Data from 13 of the 63 volunteers served for the detection of the PWV-BP relationship. The created non-linear function was used to calculate BP values after individual correction for the BP offset in a group of 50 volunteers. Individual correlation coefficients for SBP measured by PTT (SBP(PTT)) and by cuff (SBP(CUFF)) varied between r = 0.69 and r = 0.99. Taking all data together, we found r = 0.83 (276 measurements in 50 volunteers). In the Bland-Altman plot, the limits of agreement were mean(SBPPTT,)SBP(CUFF)+/- A 19.8 mmHg. In conclusion, comparing SBP values using the PTT-based method and those measured by cuff resulted in a significant correlation. However, the Bland-Altman plot shows relevant differences between both methods, which are partly due to greater variability of the SBP(PTT) measurement during intensified exercise. Results suggest that PTT can be used for measuring absolute SBP when performing an individual correction for the offset of the BP-PWV relation.
引用
收藏
页码:309 / 315
页数:7
相关论文
共 33 条
[1]  
[Anonymous], 2010, R Foundation for Statistical Computing
[2]   Continuous blood pressure determination during exercise ECG recording [J].
Barschdorff, D ;
Erig, M .
BIOMEDIZINISCHE TECHNIK, 1998, 43 (03) :34-39
[3]   Validation of continuous blood pressure measurements by pulse transit time: a comparison with invasive measurements in a cardiac intensive care unit [J].
Bartsch, S. ;
Ostojic, D. ;
Schmalgemeier, H. ;
Bitter, T. ;
Westerheide, N. ;
Eckert, S. ;
Horstkotte, D. ;
Oldenburg, O. .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2010, 135 (48) :2406-2412
[4]   CALCULATING CORRELATION-COEFFICIENTS WITH REPEATED OBSERVATIONS .2. CORRELATION BETWEEN SUBJECTS [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1995, 310 (6980) :633-633
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   MEASURING BLOOD-PRESSURE IN PREGNANT-WOMEN - A COMPARISON OF DIRECT AND INDIRECT METHODS [J].
BROWN, MA ;
REITER, L ;
SMITH, B ;
BUDDLE, ML ;
MORRIS, R ;
WHITWORTH, JA .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (03) :661-667
[7]   THE RELATIONSHIP BETWEEN ARTERIAL PULSE-WAVE VELOCITY AND PULSE FREQUENCY AT DIFFERENT PRESSURES [J].
CALLAGHAN, FJ ;
BABBS, CF ;
BOURLAND, JD ;
GEDDES, LA .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1984, 8 (01) :15-18
[8]  
CAMPBELL NRC, 1990, CAN MED ASSOC J, V143, P19
[9]   Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration [J].
Chen, W ;
Kobayashi, T ;
Ichikawa, S ;
Takeuchi, Y ;
Togawa, T .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) :569-574
[10]   Continuous and Noninvasive Blood Pressure Measurement: A Novel Modeling Methodology of the Relationship Between Blood Pressure and Pulse Wave Velocity [J].
Chen, Yan ;
Wen, Changyun ;
Tao, Guocai ;
Bi, Min ;
Li, Guoqi .
ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (11) :2222-2233