Unexpected retention behavior of baicalin: Hydrophilic interaction like properties of a reversed-phase column

被引:4
作者
Magda, Balazs [1 ]
Marta, Zoltan [1 ]
Imre, Timea [1 ]
Kalapos-Kovacs, Bernadett [2 ]
Klebovich, Imre [2 ]
Fekete, Jeno [3 ]
Szabo, Pal T. [1 ]
机构
[1] Hungarian Acad Sci, IOC RCNS HAS, H-1117 Budapest, Hungary
[2] Semmelweis Univ, Dept Pharmaceut, H-1092 Budapest, Hungary
[3] Budapest Univ Technol & Econ, Fac Chem Technol & Biotechnol, Dept Inorgan & Analyt Chem, H-1111 Budapest, Hungary
关键词
Baicalin; Reversed-phase chromatography; Hydrophilic interaction chromatography; LC-MS/MS; Vesicular transport assay; PERFORMANCE LIQUID-CHROMATOGRAPHY; RADIX-SCUTELLARIAE EXTRACT; TANDEM MASS-SPECTROMETRY; SILICA STATIONARY-PHASE; RAT PLASMA; COMPARATIVE PHARMACOKINETICS; LC-MS/MS; WOGONIN; WOGONOSIDE; GLUCURONIDES;
D O I
10.1016/j.jpba.2015.03.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The original aim of this study was to develop a method for the determination of baicalin from membrane vesicles. The unconventional chromatographic separation ("inverse gradient elution" on a reversed phase column) was due to a lucky chance, which is detailed and discussed in this study. The validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is proved to be sensitive, rapid and selective. Chromatographic separation was performed on a Zorbax SB-C8 column (250 mm x 4.6 mm, i.d.; 5 mu m) with 0.1% formic acid in water and methanol by linear gradient elution. Quantification of baicalin was determined by multiple reaction monitoring (MRM) mode using electrospray ionization (ESI). The calibration curve was linear (r=0.9987) over the concentration range from 1 to 1000 nM. The coefficient of variation and relative error of baicalin for intra- and inter-assay at three quality control (QC) levels were 2.0-10.2% and -6.1 to 6.7%, respectively. The lower limit of quantification (LLOQ) for baicalin was 1 nM (0.446 ng/ml), without preconcentration of the sample. This method was subsequently applied to vesicular transport assays of baicalin in membrane vesicles successfully. The developed method can open up new area of research in the chromatographic separation of flavonoids and their glucuronides. (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:119 / 125
页数:7
相关论文
共 50 条
  • [11] Hydrophilic interaction chromatography as an alternative to reversed-phase HPLC in determining anthocyanins and betacyanins
    Deineka, V. I.
    Saenko, I. I.
    Deineka, L. A.
    Blinova, I. P.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (03) : 297 - 301
  • [12] Poly(L-lactic acid)-modified silica stationary phase for reversed-phase and hydrophilic interaction liquid chromatography
    Ohyama, Kaname
    Takasago, Shizuka
    Kishikawa, Naoya
    Kuroda, Naotaka
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (05) : 720 - 723
  • [13] Contributions to reversed-phase column selectivity. I. Steric interaction
    Carr, P. W.
    Dolan, J. W.
    Neue, U. D.
    Snyder, L. R.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (13) : 1724 - 1742
  • [14] A float mechanism of retention in reversed-phase chromatography
    Deineka, V. I.
    Deineka, L. A.
    Saenko, I. I.
    Chulkov, A. N.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2015, 89 (07) : 1300 - 1304
  • [15] Retention in reversed-phase chromatography:: partition or adsorption?
    Vailaya, A
    Horváth, C
    JOURNAL OF CHROMATOGRAPHY A, 1998, 829 (1-2) : 1 - 27
  • [16] Preparation of pH-responsive stationary phase for reversed-phase liquid chromatography and hydrophilic interaction chromatography
    Ma, Qiao
    Chen, Ming
    Yin, Hong-Rui
    Shi, Zhi-Guo
    Feng, Yu-Qi
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1212 (1-2) : 61 - 67
  • [17] Recent advances in the design of organic polymer monoliths for reversed-phase and hydrophilic interaction chromatography separations of small molecules
    Jiri Urban
    Pavel Jandera
    Analytical and Bioanalytical Chemistry, 2013, 405 : 2123 - 2131
  • [18] A comparison and column selection of Hydrophilic Interaction Liquid Chromatography and Reversed-Phase High-Performance Liquid Chromatography for detection of DNA methylation
    Rastegar, Leila
    Mighani, Hossein
    Ghassempour, Alireza
    ANALYTICAL BIOCHEMISTRY, 2018, 557 : 123 - 130
  • [19] Preparation and Evaluation of Poly-L-Lysine Stationary Phase for Hydrophilic Interaction/Reversed-Phase Mixed-Mode Chromatography
    Li, Yuanyuan
    Xu, Zhigang
    Feng, Yaoyao
    Liu, Xiaoyan
    Chen, Tong
    Zhang, Haixia
    CHROMATOGRAPHIA, 2011, 74 (7-8) : 523 - 530
  • [20] Comparison of reversed-phase liquid chromatography and hydrophilic interaction chromatography for the fingerprint analysis of Radix isatidis
    Zhang, Cong-En
    Xiong, Yin
    Dong, Qin
    Gao, Dan
    Zhang, Le-Le
    Ma, Li-Na
    Peng, Cheng
    Dong, Xiao-Ping
    Yan, Dan
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (9-10) : 1141 - 1147