Unexpected retention behavior of baicalin: Hydrophilic interaction like properties of a reversed-phase column

被引:4
|
作者
Magda, Balazs [1 ]
Marta, Zoltan [1 ]
Imre, Timea [1 ]
Kalapos-Kovacs, Bernadett [2 ]
Klebovich, Imre [2 ]
Fekete, Jeno [3 ]
Szabo, Pal T. [1 ]
机构
[1] Hungarian Acad Sci, IOC RCNS HAS, H-1117 Budapest, Hungary
[2] Semmelweis Univ, Dept Pharmaceut, H-1092 Budapest, Hungary
[3] Budapest Univ Technol & Econ, Fac Chem Technol & Biotechnol, Dept Inorgan & Analyt Chem, H-1111 Budapest, Hungary
关键词
Baicalin; Reversed-phase chromatography; Hydrophilic interaction chromatography; LC-MS/MS; Vesicular transport assay; PERFORMANCE LIQUID-CHROMATOGRAPHY; RADIX-SCUTELLARIAE EXTRACT; TANDEM MASS-SPECTROMETRY; SILICA STATIONARY-PHASE; RAT PLASMA; COMPARATIVE PHARMACOKINETICS; LC-MS/MS; WOGONIN; WOGONOSIDE; GLUCURONIDES;
D O I
10.1016/j.jpba.2015.03.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The original aim of this study was to develop a method for the determination of baicalin from membrane vesicles. The unconventional chromatographic separation ("inverse gradient elution" on a reversed phase column) was due to a lucky chance, which is detailed and discussed in this study. The validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is proved to be sensitive, rapid and selective. Chromatographic separation was performed on a Zorbax SB-C8 column (250 mm x 4.6 mm, i.d.; 5 mu m) with 0.1% formic acid in water and methanol by linear gradient elution. Quantification of baicalin was determined by multiple reaction monitoring (MRM) mode using electrospray ionization (ESI). The calibration curve was linear (r=0.9987) over the concentration range from 1 to 1000 nM. The coefficient of variation and relative error of baicalin for intra- and inter-assay at three quality control (QC) levels were 2.0-10.2% and -6.1 to 6.7%, respectively. The lower limit of quantification (LLOQ) for baicalin was 1 nM (0.446 ng/ml), without preconcentration of the sample. This method was subsequently applied to vesicular transport assays of baicalin in membrane vesicles successfully. The developed method can open up new area of research in the chromatographic separation of flavonoids and their glucuronides. (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:119 / 125
页数:7
相关论文
共 50 条
  • [1] Orthogonal separation on one beta-cyclodextrin column by switching reversed-phase liquid chromatography and hydrophilic interaction chromatography
    Feng, Jia-tao
    Guo, Zhi-mou
    Shi, Hui
    Gu, Jiang-ping
    Jin, Yu
    Liang, Xin-miao
    TALANTA, 2010, 81 (4-5) : 1870 - 1876
  • [2] System Maps for the Retention of Neutral Compounds on an Electrostatic-Shielded Reversed-Phase Column
    Atapattu, Sanka N.
    Johnson, Kevin R. D.
    Poole, Colin F.
    CHROMATOGRAPHIA, 2019, 82 (05) : 799 - 808
  • [3] Separation properties of novel and commercial polar stationary phases in hydrophilic interaction and reversed-phase liquid chromatography mode
    Wu, JunYan
    Bicker, Wolfgang
    Lindner, Wolfgang
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (09) : 1492 - 1503
  • [4] Preparation of a monolithic column with a mixed-mode stationary phase of reversed-phase/hydrophilic interaction for capillary liquid chromatography
    Zhang, Meng
    Gong, Li
    Liu, Guizhen
    Kang, Jingwu
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (03) : 662 - 669
  • [5] HILIC behavior of a reversed-phase/cation-exchange/anion-exchange trimode column
    Liu, Xiaodong
    Pohl, Christopher A.
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (6-7) : 779 - 786
  • [6] Recent advances in the design of organic polymer monoliths for reversed-phase and hydrophilic interaction chromatography separations of small molecules
    Urban, Jiri
    Jandera, Pavel
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (07) : 2123 - 2131
  • [7] Preparation and characterization of polymethacrylate monolithic capillary columns with dual hydrophilic interaction reversed-phase retention mechanism for polar compounds
    Urban, Jiri
    Skerikova, Veronika
    Jandera, Pavel
    Kubickova, Romana
    Pospisilova, Marcela
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (15-16) : 2530 - 2543
  • [8] Ion-pair reversed-phase and hydrophilic interaction chromatography methods for analysis of phosphorothioate oligonucleotides
    Gilar, Martin
    Koshel, Brooke M.
    Birdsall, Robert E.
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1712
  • [9] Comparison of hydrophilic-interaction, reversed-phase and porous graphitic carbon chromatography for glycan analysis
    Melmer, Michael
    Stangler, Thomas
    Premstaller, Andreas
    Lindner, Wolfgang
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (01) : 118 - 123
  • [10] Hydrophilic interaction chromatography as an alternative to reversed-phase HPLC in determining anthocyanins and betacyanins
    V. I. Deineka
    I. I. Saenko
    L. A. Deineka
    I. P. Blinova
    Journal of Analytical Chemistry, 2016, 71 : 297 - 301