Novel CeO2-based screen-printed potentiometric electrodes for pH monitoring

被引:25
作者
Betelu, S. [1 ]
Polychronopoulou, K. [2 ]
Rebholz, C. [2 ]
Ignatiadis, I. [1 ]
机构
[1] Bur Rech Geol & Minieres, Environm & Proc Div, F-45060 Orleans 2, France
[2] Univ Cyprus, Mech & Mfg Engn Dept, CY-1678 Nicosia, Cyprus
关键词
pH sensing; Cerium-based oxides; Mass modified screen-printed electrodes; Monitoring; PROTON CONDUCTING CERAMICS; SUPPORTED-RH CATALYSTS; METAL-OXIDE ELECTRODES; RUTHENIUM DIOXIDE; ALKALINE-PHOSPHATASE; CERIA CERAMICS; SENSORS; FILM; MEMBRANE; TEMPERATURES;
D O I
10.1016/j.talanta.2011.09.051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nuclear waste repositories are being installed in deep excavated rock formations in some places in Europe to isolate and store radioactive waste. In France, the Callovo-Oxfordian formation (COx) is a possible candidate for nuclear waste storage. This work investigates the applicability of CeO2-based oxides (CeO2, Ce0.8Sm0.2O2 and Ce0.8Zr0.2O2) for monitoring the pH of the COx pore water (T = 25 degrees C). The study is limited to the pH range between 5.5 and 13.2, which includes the pH values that have been encountered or are anticipated in the COx formation during its evolution as radioactive waste repository due mainly to alkalinisation, an increase in salinity, and a decrease in redox potential. Screen-printing was done to assemble electrodes and rapidly generate data sets. The electrochemical behavior of CeO2-based screen-printed electrodes (CeO2-based SPEs) was determined by cyclic voltammetry and electrochemical impedance spectroscopy. The use of the electrodes for pH sensing was then evaluated by potentiometric measurements. The feasibility of measuring pH with CeO2-based SPEs was first tested in NH4Cl/NH3 buffer solutions, leading to electrode calibration over the widest range of pH, from around neutral to basic pH. Experiments were then conducted in NaHCO3/Na2CO3 buffer samples similar to conditions prevailing in the COx formation. Ce0.8Zr0.2O2 SPEs exhibit a near-Nernstian behavior (sensitivity -(51 +/- 2) mV/pH) in the pH range of 5.5-13.2 at 25 degrees C. Electrode response was slightly affected by the direction of the pH change. Electrode reliability was clearly demonstrated for pH monitoring. Probes based on the same components, but more durably designed, could be considered for pH measurements in radioactive waste repositories. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:126 / 135
页数:10
相关论文
共 60 条
  • [1] Investigation of tin oxides as sensing layers in conductimetric interdigitated pH sensors
    Arshak, K.
    Gillb, E.
    Arshak, A.
    Korostynska, O.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (01) : 42 - 53
  • [2] Authier L, 1998, ELECTROANAL, V10, P1255, DOI 10.1002/(SICI)1521-4109(199812)10:18<1255::AID-ELAN1255>3.0.CO
  • [3] 2-0
  • [4] Subfemtomolar determination of alkaline phosphatase at a disposable screen-printed electrode modified with a perfluorosulfonated ionomer film
    Bagel, O
    Limoges, B
    Schollhorn, B
    Degrand, C
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (22) : 4688 - 4694
  • [5] AC-IMPEDANCE STUDIES OF RARE-EARTH-OXIDE DOPED CERIA
    BALAZS, GB
    GLASS, RS
    [J]. SOLID STATE IONICS, 1995, 76 (1-2) : 155 - 162
  • [6] Bard A.J., 1983, ELECTROCHIMIE PRINCI
  • [7] Screen-printed electrografted electrode for trace uranium analysis
    Betelu, Stephanie
    Vautrin-Ul, Christine
    Ly, Jacques
    Chausse, Annie
    [J]. TALANTA, 2009, 80 (01) : 372 - 376
  • [8] Novel 4-carboxyphenyl-grafted screen-printed electrode for trace Cu(II) determination
    Betelu, Stephanie
    Vautrin-Ul, Christine
    Chausse, Annie
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (02) : 383 - 386
  • [9] HYSTERESIS IN AL2O3-GATE ISFETS
    BOUSSE, L
    VANDENVLEKKERT, HH
    DEROOIJ, NF
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1990, 2 (02) : 103 - 110
  • [10] Brookins D.G., 1988, EH PH DIAGRAMS GEOCH