Life, Death, and In-Between: Meanings and Methods in Microbiology

被引:190
作者
Davey, Hazel M. [1 ]
机构
[1] Aberystwyth Univ, Inst Biol Environm & Rural Sci, Aberystwyth SY23 3DA, Dyfed, Wales
关键词
FLOW-CYTOMETRIC ANALYSIS; SINGLE-CELL ANALYSES; MICROCOCCUS-LUTEUS; SACCHAROMYCES-CEREVISIAE; BACTERIAL-GROWTH; VIABLE BACTERIA; VIABILITY; DORMANCY; CULTURES; RESUSCITATION;
D O I
10.1128/AEM.00744-11
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Determination of microbial viability by the plate count method is routine in microbiology laboratories worldwide. However, limitations of the technique, particularly with respect to environmental microorganisms, are widely recognized. Many alternatives based upon viability staining have been proposed, and these are often combined with techniques such as image analysis and flow cytometry. The plethora of choices, however, adds to confusion when selecting a method. Commercial staining kits aim to simplify the performance of microbial viability determination but often still need adaptation to the specific organism of interest and/or the instruments available to the researcher. This review explores the meaning of microbial viability and offers guidance in the selection and interpretation of viability testing methods.
引用
收藏
页码:5571 / 5576
页数:6
相关论文
共 44 条
  • [1] Heterotrophic plate count bacteria - what is their significance in drinking water?
    Allen, MJ
    Edberg, SC
    Reasoner, DJ
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2004, 92 (03) : 265 - 274
  • [2] Applications of flow cytometry to clinical microbiology
    Alvarez-Barrientos, A
    Arroyo, J
    Cantón, R
    Nombela, C
    Sánchez-Pérez, M
    [J]. CLINICAL MICROBIOLOGY REVIEWS, 2000, 13 (02) : 167 - +
  • [3] Flow cytometric method for the assessment of the minimal inhibitory concentrations of antibacterial agents to Mycoplasma agalactiae
    Assuncao, Patricia
    Antunes, Nuno T.
    Rosales, Ruben S.
    de la Fe, Christian
    Poveda, Carlos
    Poveda, Jose B.
    Davey, Hazel M.
    [J]. CYTOMETRY PART A, 2006, 69A (10) : 1071 - 1076
  • [4] Barbesti S, 2000, CYTOMETRY, V40, P214, DOI 10.1002/1097-0320(20000701)40:3<214::AID-CYTO6>3.3.CO
  • [5] 2-D
  • [6] Assessment and interpretation of bacterial viability by using the LIVE/DEAD BacLight kit in combination with flow cytometry
    Berney, Michael
    Hammes, Frederik
    Bosshard, Franziska
    Weilenmann, Hans-Ulrich
    Egli, Thomas
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2007, 73 (10) : 3283 - 3290
  • [7] Boulton C., 2006, Brewing yeast and fermentation
  • [8] Optimization of yeast cell cycle analysis and morphological characterization by multispectral imaging flow cytometry
    Calvert, Meredith E. K.
    Lannigan, Joanne A.
    Pemberton, Lucy F.
    [J]. CYTOMETRY PART A, 2008, 73A (09) : 825 - 833
  • [9] COSSARIZZA A, CYTOMETRY A, V77, P721
  • [10] Red but not dead? Membranes of stressed Saccharomyces cerevisiae are permeable to propidium iodide
    Davey, H. M.
    Hexley, P.