Demagnetization Fault Detection for Double-Sided Permanent Magnet Linear Motor Based on Three-Line Magnetic Signal Signature Analysis

被引:16
作者
Song, Juncai [1 ]
Zhao, Jiwen [1 ]
Dong, Fei [2 ]
Zhao, Jing [2 ]
Song, Xuewei [3 ]
机构
[1] Hefei Univ Technol, Sch Elect & Automat Engn, Hefei 230009, Peoples R China
[2] Anhui Univ, Sch Elect Engn & Automat, Hefei 230601, Peoples R China
[3] Mie Univ, Grad Sch, Tsu, Mie 5148507, Japan
基金
中国国家自然科学基金;
关键词
Continuous wavelet transform (CWT); demagnetization fault detection; double-sided permanent magnet synchronous linear motors (DS-PMSLM); magnetic signals; peak detecting; three-line method (TLM); PEAK DETECTION; DESIGN; OPTIMIZATION; MACHINES; BEARING;
D O I
10.1109/TMECH.2019.2961175
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article investigates a novel demagnetization fault detection method for double-sided permanent magnet synchronous linear motors (DS-PMSLM) that are applied in laser cutting machines. First, a finite-element analysis model of DS-PMSLM is built to preset different demagnetization faults of the permanent magnets (PMs). Second, magnetic intensity distribution signals in air gap region are selected as fault signal for the first time to detect demagnetization faults in DS-PMSLM. Three-line method coupled with self-designed connection structure is originally proposed to obtain and analyze three-line magnetic signals. Simulation comparison with back electromotive force signal validates that three-line magnetic signals are more effective to solve the problem for this double-sided structure PMSLM. Then, continuous wavelet transform (CWT) is innovatively introduced to conduct peak feature extraction for magnetic signals. Comparison experiments between CWT, direct locating method, and polynomial fitting method certify the superiority of CWT. By peak feature analysis, the positions, sides, and severity degrees of PMs' demagnetization faults can be detected accurately. Finally, a prototype is manufactured, and a Gauss meter experimental platform is established to verify the validity and advantages of this method.
引用
收藏
页码:815 / 827
页数:13
相关论文
共 31 条
  • [21] Electromagnetic Characteristics Analysis of a Novel Ironless Double-Sided Halbach Permanent Magnet Synchronous Linear Motor for Electromagnetic Launch Considering Longitudinal End Effect
    Mao, Yinhao
    Sun, Zhaolong
    Huang, Chuibing
    Jia, Guangyong
    Ding, Anmin
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2024, 10 (03): : 7467 - 7477
  • [22] Detent Force, Thrust, and Normal Force of the Short-Primary Double-Sided Permanent Magnet Linear Synchronous Motor With Slot-Shift Structure
    Huang, XuZhen
    Ji, TianPeng
    Li, LiYi
    Zhou, Bo
    Zhang, ZhuoRan
    Gerada, David
    Gerada, Chris
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2019, 34 (03) : 1411 - 1421
  • [23] Performance analysis and optimization of secondary U-shaped double-sided toroidal winding linear permanent magnet vernier machine
    Xu, Xiaozhuo
    Miao, Sen
    Jiang, Siyuan
    Feng, Haichao
    Ai, Liwang
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2024, 59
  • [24] Comparative Study of Armature Reaction Field Analysis for Tubular Linear Machine with Axially Magnetized Single-sided and Double-sided Permanent Magnet Based on Analytical Field Calculations
    Shin, Kyung-Hun
    Park, Min-Gyu
    Cho, Han-Wook
    Choi, Jang-Young
    JOURNAL OF MAGNETICS, 2015, 20 (01) : 79 - 85
  • [25] Double-sided permanent-magnet radial-flux eddy-current couplers: three-dimensional analytical modelling, static and transient study, and sensitivity analysis
    Mohammadi, Sajjad
    Mirsalim, Mojtaba
    IET ELECTRIC POWER APPLICATIONS, 2013, 7 (09) : 665 - 679
  • [26] Analysis of double-sided sandwiched linear flux-switching permanent-magnet machines with staggered stator teeth for urban rail transit
    Hao, Wenjuan
    Wang, Yu
    IET ELECTRICAL SYSTEMS IN TRANSPORTATION, 2018, 8 (03) : 175 - 181
  • [27] Electromagnetic Analysis and Experimental Testing of a Tubular Linear Synchronous Machine With a Double-Sided Axially Magnetized Permanent Magnet Mover and Coreless Stator Windings by Using Semianalytical Techniques
    Park, Min-Gyu
    Choi, Jang-Young
    Shin, Hyeon-Jae
    Lee, Kangsu
    Hong, Keyyong
    IEEE TRANSACTIONS ON MAGNETICS, 2014, 50 (11)
  • [28] Analysis on operational power and eddy current losses for applying coreless double-sided permanent magnet synchronous motor/generator to high-power flywheel energy storage system
    Jang, Seok-Myeong
    Park, Ji-Hoon
    You, Dae-Joon
    Choi, Sang-Ho
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (07)
  • [29] An effective Hilbert-Huang transform-based approach for dynamic eccentricity fault diagnosis in double-rotor double-sided stator structure axial flux permanent magnet generator under various load and speed conditions
    Torabi, Makan
    Alinejad-beromi, Yousef
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2023, 31 (01) : 53 - 76
  • [30] Presentation of a Novel Transverse-Flux Permanent Magnet Linear Motor and Its Magnetic Field Analysis Based on Schwarz-Christoffel Mapping Method
    Fu, Dongshan
    Xu, Yanliang
    Gillon, Frederic
    Gong, Jinlin
    Bracikowski, Nicolas
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (03)