In Silico Evaluation of Treatment of Periprosthetic Fractures in Elderly Patients After Hip Arthroplasty

被引:2
作者
Lorkowski, Jacek [1 ]
Wilk, Renata [2 ,3 ]
Pokorski, Mieczyslaw [4 ]
机构
[1] Minist Interior, Cent Clin Hosp, Dept Orthoped & Traumatol, Warsaw, Poland
[2] Med Univ Silesia, Hlth Sci Dept, Dept Anat, Katowice, Poland
[3] Hope Med Inst, Newport News, VA USA
[4] Opole Med Sch, Inst Hlth Sci, Opole, Poland
来源
MEDICAL AND BIOMEDICAL UPDATES | 2021年 / 1289卷
关键词
Elderly patients; Endoprosthesis; Finite element model; Hip arthroplasty; In silico; Periprosthetic fracture; FEMUR;
D O I
10.1007/5584_2020_555
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The aim of this study was to investigate the soundness of in silico finite element model (FEM) in the assessment of strain in the femur and in the components fixing the periprosthetic fracture in elderly patients after hip arthroplasty. From a group of 55 patients, aged 27-95, treated due to fractures after hip replacement in 2012-2018, 18 patients were separated out, aged over 85, out of whom 7 had type C fractures, according to the Vancouver classification. These seven patients formed the study group. The fractures were stabilized with a locking compression plate system and wire loops or by replacement of the endoprosthesis stem. The FEM was performed by processing radiological images of the femur, considering the stabilization type and osteoporotic bone characteristics. Each patient's FEM was counter compared to virtual in silico control showing a non-osteoporotic bone structure. We found that the strain was distinctly greater at the bone-implant interface after surgical stabilization with a multi-hole plate and cerclage wire loops in osteoporotic periprosthetic fractures when compared to the virtual non-osteoporotic bone. We conclude that the in silico model enables the assessment of strain distribution at the bone-implant interface, which helps identify the biomechanical incongruity of traditional bone stabilization methods in patients with osteoporotic bones.
引用
收藏
页码:115 / 123
页数:9
相关论文
共 25 条
[21]   A large proportion of patients with small ruptured abdominal aortic aneurysms are women and have chronic obstructive pulmonary disease [J].
Siika, Antti ;
Liljeqvist, Moritz Lindquist ;
Zommorodi, Sayid ;
Nilsson, Olga ;
Andersson, Patricia ;
Gasser, T. Christian ;
Roy, Joy ;
Hultgren, Rebecka .
PLOS ONE, 2019, 14 (05)
[22]   Finite element analysis in symptomatic and asymptomatic abdominal aortic aneurysms for aortic disease risk stratification [J].
Soto, Begona ;
Vila, Luis ;
Dilme, Jaume ;
Escudero, Jose-Roman ;
Bellmunt, Sergi ;
Camacho, Mercedes .
INTERNATIONAL ANGIOLOGY, 2018, 37 (06) :479-485
[23]   Fractures of the femur after hip replacement - The Oregon experience [J].
Tower, SS ;
Beals, RK .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :235-+
[24]   Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur [J].
Wirtz, DC ;
Schiffers, N ;
Pandorf, T ;
Radermacher, K ;
Weichert, D ;
Forst, R .
JOURNAL OF BIOMECHANICS, 2000, 33 (10) :1325-1330
[25]   High incidence of complications and poor clinical outcome in the operative treatment of periprosthetic femoral fractures: An analysis of 71 cases [J].
Zuurmond, R. G. ;
van Wijhe, W. ;
van Raay, J. J. A. M. ;
Bulstra, S. K. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (06) :629-633