The Sensitivity of Grating-Based SPR Sensors with Wavelength Interrogation

被引:76
作者
Cao, Jianjun [1 ]
Sun, Yuan [1 ]
Kong, Yan [1 ]
Qian, Weiying [1 ]
机构
[1] Jiangnan Univ, Sch Sci, Wuxi 214122, Peoples R China
基金
中国国家自然科学基金;
关键词
surface plasmon resonance; metal grating; sensitivity enhancement; biosensor; SURFACE-PLASMON-RESONANCE; ENHANCEMENT; LAYER; WAVES;
D O I
10.3390/s19020405
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we derive the analytical expression for the sensitivity of grating-based surface plasmon resonance (SPR) sensors working in wavelength interrogation. The theoretical analysis shows that the sensitivity increases with increasing wavelength and is saturated beyond a certain wavelength for Au and Ag gratings, while it is almost constant for Al gratings in the wavelength range of 500 to 1000 nm. More importantly, the grating period (P) and the diffraction order (m) dominate the value of sensitivity. Higher sensitivity is possible for SPR sensors with a larger grating period and lower diffraction order. At long wavelengths, a simple expression of P/|m| can be used to estimate the sensor sensitivity. Moreover, we perform experimental measurements of the sensitivity of an SPR sensor based on an Al grating to confirm the theoretical calculations.
引用
收藏
页数:9
相关论文
共 35 条
[1]   Enhanced SPR sensitivity using periodic metallic structures [J].
Alleyne, Colin J. ;
Kirk, Andrew G. ;
McPhedran, Ross C. ;
Nicorovici, Nicolae-Alexandru P. ;
Maystre, Daniel .
OPTICS EXPRESS, 2007, 15 (13) :8163-8169
[2]   Surface plasmon resonance based fiber optic refractive index sensor utilizing silicon layer: Effect of doping [J].
Bhatia, Priya ;
Gupta, Banshi D. .
OPTICS COMMUNICATIONS, 2013, 286 :171-175
[3]   Surface-plasmon-resonance-based fiber-optic refractive index sensor: sensitivity enhancement [J].
Bhatia, Priya ;
Gupta, Banshi D. .
APPLIED OPTICS, 2011, 50 (14) :2032-2036
[4]   Resolution enhancement of surface plasmon resonance sensors with spectral interrogation: resonant wavelength considerations [J].
Chen, Zhenling ;
Liu, Le ;
He, Yonghong ;
Ma, Hui .
APPLIED OPTICS, 2016, 55 (04) :884-891
[5]  
CULLEN DC, 1987, BIOSENSORS, V3, P211
[6]   A smartphone based surface plasmon resonance imaging (SPRi) platform for on-site biodetection [J].
Guner, Hasan ;
Ozgur, Erol ;
Kokturk, Guzin ;
Celik, Mehmet ;
Esen, Elif ;
Topal, Ahmet E. ;
Ayas, Sencer ;
Uludag, Yildiz ;
Elbuken, Caglar ;
Dana, Aykutlu .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 :571-577
[7]   Surface plasmon resonance sensors: review [J].
Homola, J ;
Yee, SS ;
Gauglitz, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) :3-15
[8]   On the sensitivity of surface plasmon resonance sensors with spectral interrogation [J].
Homola, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 41 (1-3) :207-211
[9]   Surface plasmon resonance sensors based on diffraction gratings and prism couplers: sensitivity comparison [J].
Homola, J ;
Koudela, I ;
Yee, SS .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) :16-24
[10]   Surface plasmon resonance sensors for detection of chemical and biological species [J].
Homola, Jiri .
CHEMICAL REVIEWS, 2008, 108 (02) :462-493