A quadrature volume RF coil for vertical B0 field open MRI systems

被引:3
|
作者
Tomanek, Boguslaw [1 ,2 ]
Volotovskyy, Vyacheslav [3 ]
Tyson, Randy [3 ]
Yin, Donghui [3 ]
Sharp, Jonathan [1 ]
Blasiak, Barbara [2 ,4 ]
机构
[1] Univ Alberta, Dept Oncol, Med Phys Div, Edmonton, AB, Canada
[2] Polish Acad Sci, Inst Nucl Phys, Krakow, Poland
[3] Cross Canc Inst, Dept Med Phys, Edmonton, AB, Canada
[4] Univ Calgary, Dept Neurosci, Calgary, AB, Canada
关键词
body RF coil; low-field MRI; quadrature RF coil; vertical field MRI; BIRDCAGE COIL; EFFICIENT; DESIGN;
D O I
10.1002/cmr.b.21327
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Cylindrical quadrature radio frequency (RF) coils are widely used in magnetic resonance imaging and spectroscopy due to their high sensitivity and field uniformity. However, the field geometry is unsuitable for use in low-field open magnetic resonance imaging (MRI) systems with vertical B-0 field configurations. Therefore, a new design is proposed. A quadrature RF coil that combines Alderman-Grant and Helmholtz designs was constructed to produce two independent modes, both orthogonal to the main magnetic field. The coil provides good RF homogeneity over a 20 x 15 x 15 cm volume and operates as both a transmit and receive coil. The application of the coil for 0.2 Tesla permanent magnet with a vertical B-0 field is shown. The proposed coil may be applied to MR imaging of larger objects at low vertical magnetic fields.
引用
收藏
页码:118 / 122
页数:5
相关论文
共 24 条
  • [21] Approaches in cooling of resistive coil-based low-field Magnetic Resonance Imaging (MRI) systems for application in low resource settings
    Faith Natukunda
    Theodora M. Twongyirwe
    Steven J. Schiff
    Johnes Obungoloch
    BMC Biomedical Engineering, 3 (1):
  • [22] Development and evaluation of a 16-channel receive-only RF coil to improve 7T ultra-high field body MRI with focus on the spine
    Rietsch, Stefan H. G.
    Brunheim, Sascha
    Orzada, Stephan
    Voelker, Maximilian N.
    Maderwald, Stefan
    Bitz, Andreas K.
    Gratz, Marcel
    Ladd, Mark E.
    Quick, Harald H.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (02) : 796 - 810
  • [23] RF heating of deep brain stimulation implants during MRI in 1.2 T vertical scanners versus 1.5 T horizontal systems: A simulation study with realistic lead configurations
    Kazemivalipour, Ehsan
    Vu, Jasmine
    Lin, Stella
    Bhusal, Bhumi
    Bach Thanh Nguyen
    Kirsch, John
    Elahi, Behzad
    Rosenow, Joshua
    Atalar, Ergin
    Golestanirad, Laleh
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 6143 - 6146
  • [24] Extending the MaRCoS: A 4-Rx Open-Source MRI Console for Low-, Mid-, and High-Field Systems
    Wang, Hanlei
    Lou, Feiyang
    Huang, Yiman
    Gao, Yang
    Zhang, Xiaotong
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2025,