Seismic performance of a cable-stayed footbridge using a concrete damage plasticity model

被引:7
作者
Drygala, Izabela J. [1 ]
Dulinska, Joanna M. [1 ]
Wazowski, Marek [2 ]
机构
[1] Cracow Univ Technol, Inst Struct Mech, Warszawska 24, PL-31155 Krakow, Poland
[2] Aspekt Lab Sp Zoo, Chopina 96, PL-43600 Jaworzno, Poland
来源
INTERNATIONAL CONFERENCE ON ANALYTICAL MODELS AND NEW CONCEPTS IN CONCRETE AND MASONRY STRUCTURES | 2017年 / 193卷
关键词
concrete damage plasticity model; footbridges; dynamic response; seismic performance; modal assurance criterion; SERVICEABILITY;
D O I
10.1016/j.proeng.2017.06.246
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a non-linear dynamic analysis of a cable-stayed footbridge to an earthquake is presented. The investigation was performed for an existing pedestrian bridge located in Czestochowa, Southern Poland. The total length of the structure is 46.90 m. The suspended structure consists of two spans (21.10 m and 25.80 m). The deck of the footbridge is made of a steel-concrete composite and is connected to the steel pylon by cables. The structure is equipped with elastomeric bearings as linking elements between the deck and the pillars. A three-dimensional FE model of the footbridge was created with the ABAQUS software program. For the verification of numerical model the modal assurance criterion (MAC) was applied. The acceleration time history of the registered shock was used as seismic excitation acting in three directions. The peak ground acceleration (PGA) of the shock was 0.4 g. To represent the inelastic behavior of the footbridges' deck under the earthquake, a concrete damage plasticity model was assumed as a constitutive model for the concrete. It turned out that the analyzed shock was strong enough to cause severe destruction in the reinforced concrete deck of the footbridge. (c) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:525 / 532
页数:8
相关论文
共 50 条
  • [21] Seismic performance assessment of a sea-crossing cable-stayed bridge system considering soil spatial variability
    Li, Chao
    Diao, Yucheng
    Li, Hong-Nan
    Pan, Haiyang
    Ma, Ruisheng
    Han, Qiang
    Xing, Yihan
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2023, 235
  • [23] Study of seismic performance of super long-span partially earth-anchored cable-stayed bridges
    Zhang, Xin-Jun
    Yu, Cong
    Zhao, Jun-Jie
    STRUCTURAL ENGINEERING AND MECHANICS, 2019, 72 (01) : 861 - 873
  • [24] Seismic performance study along the transverse direction of cable-stayed bridges with self-centering energy dissipation braces
    Xu L.-H.
    Wu H.
    Gongcheng Lixue/Engineering Mechanics, 2019, 36 (04): : 177 - 187
  • [25] GPS Performance Assessment of Cable-Stayed Bridge using Wavelet Transform and Monte-Carlo Techniques
    Hussan, Mosaruf
    Kaloop, Mosbeh R.
    Sharmin, Faria
    Kim, Dookie
    KSCE JOURNAL OF CIVIL ENGINEERING, 2018, 22 (11) : 4385 - 4398
  • [26] Transverse seismic response of diamond-shaped pylon in cable-stayed bridge: Experiment and analysis
    Zhang, Chao
    Wen, Jianian
    Han, Qiang
    Du, Xiuli
    Lai, Zhichao
    Fu, Guanghui
    ENGINEERING STRUCTURES, 2022, 250
  • [27] Dynamic behaviour of a concrete building under a mainshock-aftershock seismic sequence with a concrete damage plasticity material model
    Dulinska, Joanna Maria
    Murzyn, Izabela Joanna
    GEOMATICS NATURAL HAZARDS & RISK, 2016, 7 : 25 - 34
  • [28] Research on Seismic Performance for Overlapping Beam of Cable-stayed Bridge Scheme of Xia-Zhang Sea-crossing Bridge
    Yan Bin
    Feng Yuncheng
    Mu Zongjun
    PROCEEDINGS OF SHANGHAI INTERNATIONAL CONFERENCE ON TECHNOLOGY OF ARCHITECTURE AND STRUCTURE, PT II, 2009, : 367 - 373
  • [29] Response Analysis for the Tower Model of a Cable-Stayed Bridge under Local Collision
    Wei, Demin
    Chen, Ying
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND APPLICATION ENGINEERING (CSAE2018), 2018,
  • [30] Shake table test on transverse steel damper seismic system for long span cable-stayed bridges
    Zhou, Lianxu
    Wang, Xiaowei
    Ye, Aijun
    ENGINEERING STRUCTURES, 2019, 179 : 106 - 119