Rapid and Sensitive Determination of Udenafil in Plasma by LC-MS/MS for Intranasal Pharmacokinetic Study in Rats

被引:6
|
作者
Ku, Wan-Sung [1 ,2 ]
Cho, Hyun-Jong [1 ,2 ]
Yoon, In-Soo [1 ,2 ]
Kim, Jeong Hoon [3 ]
Cha, Bong-Jin [3 ]
Kim, Jung Sun [4 ]
Kim, Kyeong-Mi [5 ]
Kang, Shin-Kwon [5 ]
Chung, Suk-Jae [1 ,2 ]
Shim, Chang-Koo [1 ,2 ]
Kim, Dae-Duk [1 ,2 ]
机构
[1] Seoul Natl Univ, Coll Pharm, Seoul 151742, South Korea
[2] Seoul Natl Univ, Pharmaceut Sci Res Inst, Seoul 151742, South Korea
[3] Dong A Pharm Co Ltd, Gyeonggi Do 446905, South Korea
[4] Dongseo Univ, Div Hlth Sci, Pusan 617716, South Korea
[5] LCKorea Co Ltd, R&D Inst, Seoul 150102, South Korea
关键词
LC-MS/MS; udenafil; liquid liquid extraction; intranasal delivery; pharmacokinetics; PERFORMANCE LIQUID-CHROMATOGRAPHY; ACTIVE METABOLITE; SILDENAFIL; INHIBITOR; DA-8159; URINE;
D O I
10.1248/cpb.59.1083
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A rapid and sensitive analytical method for udenafil in rat plasma was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). This chromatographic procedure was then applied to the in viva pharmacokinetic studies in rats for determining the advantages of intranasal administration of the drug over oral administration. Using liquid liquid extraction (LLE), udenafil and the internal standard (IS) sildenafil were extracted with dichloromethane from 100 mu l of plasma samples. Chromatographic separation was performed using Pursuit XRS C-18 column (50 mm x2.1 mm, i.d., 3 mu m, Varian Inc., CA, U.S.A.) with an isocratic mobile phase consisting of acetonitrile and 10 mm ammonium acetate (90: 10, v/v) at a flow rate of 0.2 ml/min over a total run time of 2.5 min. Detection and quantification was performed by mass spectrometry using the multiple reaction-monitoring mode at m/z 517.4 -> 283.1 for udenafil and m/z 475.3 -> 4100.0 for IS. Results showed that the developed method was sensitive and specific for udenafil. Linearity was obtained in the range of 0.5-1000 ng/ml. The coefficient of variation of both intra- and inter-day validation were below 11.6% and the intra- and inter-day accuracy ranged from 91.5 to 109.9%. Udenatil concentration was successfully measured from plasma after intranasal as well as after intravenous or oral administration at clinical dose (1.67 mg/kg) in rats. Moreover, the T-max values obtained from pharmacokinetic studies suggested that administration of udenafil intranasally could be more effective than by the oral route.
引用
收藏
页码:1083 / 1088
页数:6
相关论文
共 50 条
  • [31] A validated LC-MS/MS method for rapid determination of brazilin in rat plasma and its application to a pharmacokinetic study
    Deng, Zhipeng
    Wang, Xin
    Zhao, Huanxin
    Cui, Shuxiang
    Yao, Qingqiang
    Bai, Hong
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (06) : 802 - 806
  • [32] Pharmacokinetic Study of Remifentanil in Rat Plasma by LC-MS/MS
    Chen, Sheng-yang
    Zhang, Xiao-ran
    Wang, Geng-fu
    Zhang, Yong-qiang
    Liu, Jun
    Tian, Jian-min
    Hu, Jie
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (03): : 547 - 551
  • [33] Determination of efonidipine in human plasma by LC-MS/MS for pharmacokinetic applications
    Liu, Man
    Zhao, Hongna
    Tong, Yang
    Zhang, Dan
    Wang, Xiaolin
    Zhang, Lina
    Han, Jing
    Liu, Huichen
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 103 : 1 - 6
  • [34] Determination and Pharmacokinetic Study of Pachymic Acid by LC-MS/MS
    Wang, Feng-Yun
    Lv, Wei-Sheng
    Han, Liang
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2015, 38 (09) : 1337 - 1344
  • [35] LC-MS/MS determination of bakkenolide D in rats plasma and its application in pharmacokinetic studies
    Dai, Dongmei
    Pei, Lixia
    Tang, Lin
    Chen, Feng
    Chen, Xiuping
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (09) : 1200 - 1207
  • [36] Determination of tubuloside B by LC-MS/MS and its application to a pharmacokinetic study in rats
    Yang, Shengbao
    Qu, Ruiying
    Sun, Peilu
    Xiong, Shan
    Yan, Siyi
    Deng, Zhipeng
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (04)
  • [37] Determination of Dextromethorphan in Rabbit Plasma by LC-MS/MS and Its Application to Pharmacokinetic Study
    Hu, Lufeng
    Wang, Xianqin
    Jiang, Haiyan
    Xu, Xuegu
    Xu, Ren-ai
    Lin, Guanyang
    LATIN AMERICAN JOURNAL OF PHARMACY, 2010, 29 (05): : 839 - 844
  • [38] LC-MS/MS method for the determination of erianin in rat plasma: Application to a pharmacokinetic study
    Yi, Xunfei
    Lan, Xiaopeng
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (07)
  • [39] Determination of cepharanthine in rat plasma by LC-MS/MS and its application to a pharmacokinetic study
    Deng, Yingbin
    Wu, Weijun
    Ye, Sunzhi
    Wang, Wei
    Wang, Zhiyi
    PHARMACEUTICAL BIOLOGY, 2017, 55 (01) : 1775 - 1779
  • [40] Determination of Protoapigenone in Beagle Dog Plasma by LC-MS/MS: Application to a Pharmacokinetic Study
    Qin, Cheng
    Zhang, Yongjun
    Jiang, Xin
    Yin, Xueyan
    Li, Yaping
    Liu, Wanyu
    Si, Luqin
    Huang, Jiangeng
    Wei, Anhua
    REVISTA BRASILEIRA DE FARMACOGNOSIA-BRAZILIAN JOURNAL OF PHARMACOGNOSY, 2021, 31 (06): : 772 - 778