Motion Artifact Cancellation in Wearable Photoplethysmography Using Gyroscope

被引:52
|
作者
Lee, H. [1 ]
Chung, H. [1 ]
Lee, J. [1 ]
机构
[1] Wonkwang Univ, Coll Med, Dept Biomed Engn, Iksan 54538, South Korea
基金
新加坡国家研究基金会;
关键词
Accelerometer; gyroscope; motion artifacts; photoplethysmography; wearable device; REDUCTION; SIGNALS; FRAMEWORK; PPG; AGE;
D O I
10.1109/JSEN.2018.2879970
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wearable reflectance-type photoplethysmography (PPG) sensors, in the form of a band or watch, have recently gained significant attention for real-time heart rate (HR) monitoring applications. To accurately estimate the HR, even during intensive exercise, much effort has focused on simultaneously measured accelerometer signals that cancel out motion artifacts (MAs) from the PPG signal. However, the accelerometer does not always measure true MAs, as it measures not only the acceleration of motion but also gravitational acceleration corresponding to each axis of the accelerometer. In addition, the measured acceleration of the motion itself does not always coincide with the true motion. In this paper, we address the limitations of accelerometers and present an approach using a gyroscope to overcome the issues described. To the best of our knowledge, the limitations of the acceleration signals for MA cancellation have not been addressed in-depth. Here, we describe our developed wearable reflectance-type PPG sensor and compare the HR estimation performance between using a gyroscope and an accelerometer from 24 subjects. Our results showed that the gyroscope-assisted approach exhibited better performance than the accelerometer-assisted approach, especially for an exercise involving walking.
引用
收藏
页码:1166 / 1175
页数:10
相关论文
共 50 条
  • [41] Characterization of Artifact Signals in Neck Photoplethysmography
    Garcia-Lopez, Irene
    Rodriguez-Villegas, Esther
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (10) : 2849 - 2861
  • [42] Two-Pronged Motion Artifact Reduction for Wearable Photoplethysmographic Biosensors
    Jiang, Yuan
    IEEE SENSORS LETTERS, 2018, 2 (04)
  • [43] Wearable Photoplethysmography for Cardiovascular Monitoring
    Charlton, Peter H.
    Kyriacou, Panicos A.
    Mant, Jonathan
    Marozas, Vaidotas
    Chowienczyk, Phil
    Alastruey, Jordi
    PROCEEDINGS OF THE IEEE, 2022, 110 (03) : 355 - 381
  • [44] Wearable wireless photoplethysmography sensors
    Spigulis, Janis
    Erts, Renars
    Nikiforovs, Vladimirs
    Kviesis-Kipge, Edgars
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE, 2008, 6991
  • [45] Novel Noniterative Orientation Estimation for Wearable Motion Sensor Units Acquiring Accelerometer, Gyroscope, and Magnetometer Measurements
    Yurtman, Aras
    Barshan, Billur
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (06) : 3206 - 3215
  • [46] Physical Activity Recognition Based on Deep Learning Using Photoplethysmography and Wearable Inertial Sensors
    Hnoohom, Narit
    Mekruksavanich, Sakorn
    Jitpattanakul, Anuchit
    ELECTRONICS, 2023, 12 (03)
  • [47] Breathing Motion Artifact Cancellation in PPG-Based Heart Rate Sensing
    Shimazaki, Takunori
    Hara, Shinsuke
    2015 9TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION AND COMMUNICATION TECHNOLOGY (ISMICT), 2015, : 200 - 203
  • [48] Wearable Multichannel Photoplethysmography Framework for Heart Rate Monitoring During Intensive Exercise
    Lee, H.
    Chung, H.
    Ko, H.
    Lee, J.
    IEEE SENSORS JOURNAL, 2018, 18 (07) : 2983 - 2993
  • [49] Stochastic Modeling Based Nonlinear Bayesian Filtering for Photoplethysmography Denoising in Wearable Devices
    Xu, Ke
    Jiang, Xinyu
    Lin, Sijie
    Dai, Chenyun
    Chen, Wei
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2020, 16 (11) : 7219 - 7230
  • [50] Heart rate estimation from photoplethysmography signal for wearable health monitoring devices
    Arunkumar, K. R.
    Bhaskar, M.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 50 : 1 - 9