Upper limb dimensions in adults presenting for elective surgery - implications for blood pressure measurement

被引:2
作者
Chow, Christopher [1 ]
Ceglowski, Peter [1 ]
Lehane, Katie [1 ]
Pelecanos, Anita [2 ]
Wren, Kellie [1 ,3 ]
Eley, Victoria A. [1 ,3 ]
机构
[1] Univ Queensland, Fac Med, Brisbane, Qld, Australia
[2] QIMR Berghofer Med Res Inst, Brisbane, Qld, Australia
[3] Royal Brisbane & Womens Hosp, Dept Anaesthesia & Perioperat Med, Butterfield St, Herston, Qld 4006, Australia
关键词
Arm shape; Blood pressure; Measurement; Perioperative; ARTERIAL-PRESSURE; CONICAL CUFF; STANDARD; DEVICE;
D O I
10.1186/s12871-020-00994-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background Arm conicity is associated with non-invasive blood pressure (NIBP) measurement error and may be avoided by using finger cuffs. Predicting arm conicity may help decisions regarding NIBP measurement techniques. Methods We obtained upper limb measurements of adults presenting to the Pre-Anesthetic Clinic to determine: the suitability of arm and finger cuff sizes; the best anthropometric predictor of arm conicity based on the right arm slant angle; the incidence of a right arm slant angle < 83 degrees. Right mid-arm circumference (MAC) was compared to recommended cuff sizes and finger circumference compared to available cuffs. Slant angle was calculated from the measurements obtained. Linear regression was used to determine the better predictor of right arm slant angle. Correlation coefficients were calculated and R-2 values compared. Results Four hundred fifty-four patients participated and 453 had cone-shaped arms. One participant (0.2, 95% CI 0.0-1.2) had a MAC outside the recommended cuff range. Twenty-five participants (5.5, 95% CI 3.6-8.0) had a middle finger circumference greater than the largest ClearSight (TM) cuff. Body mass index (BMI), weight and right MAC all had low to moderate correlation with right arm slant angle (r = - 0.49, - 0.39, - 0.48, all p < 0.001) and regression revealed R-2 values of 0.24, 0.15 and 0.23. Six participants (1.3, 95% CI 0.5-2.9) had a slant angle < 83 degrees. Conclusion Current NIBP equipment caters for most patients, based on the traditional measure of MAC. The utility of finger cuffs is limited by cuff size. BMI and right MAC showed the most promise in predicting arm conicity.
引用
收藏
页数:6
相关论文
共 24 条
[1]  
[Anonymous], RISK FACT HLTH
[2]   Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences [J].
Bonso, Elisa ;
Saladini, Francesca ;
Zanier, Ada ;
Benetti, Elisabetta ;
Dorigatti, Francesca ;
Palatini, Paolo .
HYPERTENSION RESEARCH, 2010, 33 (11) :1186-1191
[3]   Obesity: a chronic relapsing progressive disease process. A position statement of the World Obesity Federation [J].
Bray, G. A. ;
Kim, K. K. ;
Wilding, J. P. H. .
OBESITY REVIEWS, 2017, 18 (07) :715-723
[4]  
Centers for Disease Control and Prevention/National Center for Health Statistics, 2017, NAT HLTH NUTR EX SUR
[5]   Race/ethnic issues in obesity and obesity-related comorbidities [J].
Cossrow, N ;
Falkner, B .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (06) :2590-2594
[6]   Numerical analysis of stress distribution in the upper arm tissues under an inflatable cuff: Implications for noninvasive blood pressure measurement [J].
Deng, Zhipeng ;
Liang, Fuyou .
ACTA MECHANICA SINICA, 2016, 32 (05) :959-969
[7]   Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery [J].
Fischer, M. O. ;
Avram, R. ;
Carjaliu, I. ;
Massetti, M. ;
Gerard, J. L. ;
Hanouz, J. L. ;
Fellahi, J. L. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (04) :514-521
[8]  
HUIGE MC, 1978, ACTA CARDIOL, V33, P88
[9]   Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement [J].
Ilies, C. ;
Bauer, M. ;
Berg, P. ;
Rosenberg, J. ;
Hedderich, J. ;
Bein, B. ;
Hinz, J. ;
Hanss, R. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (02) :202-210
[10]   Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin® [J].
Martina, Jerson R. ;
Westerhof, Berend E. ;
van Goudoever, Jeroen ;
de Beaumont, Edouard M. F. H. ;
Truijen, Jasper ;
Kim, Yu-Sok ;
Immink, Rogier V. ;
Jobsis, Dorothea A. ;
Hollmann, Markus W. ;
Lahpor, Jaap R. ;
de Mol, Bas A. J. M. ;
van Lieshout, Johannes J. .
ANESTHESIOLOGY, 2012, 116 (05) :1092-1103