Posterior C2 Instrumentation Accuracy and Complications Associated With Four Techniques

被引:45
作者
Bransford, Richard J. [1 ]
Russo, Anthony J. [2 ]
Freeborn, Mark [4 ]
Nguyen, Quynh T. [3 ]
Lee, Michael J. [1 ]
Chapman, Jens R. [1 ]
Bellabarba, Carlo [1 ]
机构
[1] Univ Washington, Harborview Med Ctr, Dept Orthopaed & Sports Med, Med Ctr, Seattle, WA 98195 USA
[2] Montana Orthopaed, Butte, MT USA
[3] Univ Washington, Harborview Med Ctr, Dept Radiol, Seattle, WA 98104 USA
[4] Evergreen Orthopaed Ctr, Kirkland, WA USA
关键词
C2; instrumentation; axis; C2 pedicle screw; C2 translaminar screw; transarticular screw; vertebral artery; TRANSARTICULAR SCREW FIXATION; VERTEBRAL ARTERY INJURY; LAMINAR SCREWS; C1-C2; FUSION; LATERAL MASS; PEDICLE; COMPLEX; TRANSLAMINAR; SUITABILITY; FRACTURES;
D O I
10.1097/BRS.0b013e3181fdaf06
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Retrospective review of a single tertiary care spine database to identify patients with C2 instrumentation between January 2001 and September 2008. Objective. (1) Evaluate a large series of posterior C2 screws to determine accuracy by computed tomography (CT) scan, (2) assess dimensions of "safe bony windows" with CT, and (3) assess perioperative complication rate related to errant screw placement. Summary of Background Data. The variable C2 anatomy can make instrumentation challenging and prone to potentially severe complications. New techniques have expanded available options. Methods. Clinical data were obtained from the medical record. Radiographic analyses included preoperative and postoperative CT scans to quantify the patients' bone and to classify accuracy of instrumentation. Screws were graded using the following definitions: Type I: Screw threads completely within the bone. Type II: Less than (1/2) the diameter of the screw violates the surrounding cortex. Type III: Clear violation of transverse foramen or spinal canal. Results. Seven hundred and thirty-six screws in 383 patients were identified. Fifty-five patients were excluded because of lack of data leaving 328 patients (188 male patients, 140 female patients) with 633 screws. Three hundred and thirty-nine pedicle, 154 transarticular, 63 laminar, and 77 short pars screws were placed, and of the 509 screws with postoperative CT scans, accuracy rates (Types I and II) were 98.8%, 98.5%, 100%, and 94.6%, respectively. Eight were unacceptably placed: two medially and six encroaching on the vertebral artery foramen. One patient had a vertebral artery occlusion and another had a dissection. There were no neurologic injuries. Mean CT measurements of pedicle height, axial width, and laminar width were 8.1, 5.8, and 5.7 mm respectively, with males having significantly larger pedicle height (P < 0.001), pedicle width (P < 0.001), and laminar width (P < 0.022). Conclusion. We show a lower than previously reported incidence of complications associated with posterior C2 screw placement. The multiple techniques of posterior C2 fixation available allow for flexibility in determining ideal technique.
引用
收藏
页码:E936 / E943
页数:8
相关论文
共 36 条
  • [1] Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques
    Aryan, Henry E.
    Iewman, C. Benjamin
    Nottmeier, Eric W.
    Acosta, Frank L., Jr.
    Wang, Vincent Y.
    Ames, Christopher P.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2008, 8 (03) : 222 - 229
  • [2] Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement
    Bloch, O
    Holly, LT
    Park, J
    Obasi, C
    Kim, K
    Johnson, JP
    [J]. JOURNAL OF NEUROSURGERY, 2001, 95 (01) : 74 - 79
  • [3] TREATMENT OF PEDICULAR FRACTURES OF THE AXIS - A CLINICAL-STUDY AND SCREW FIXATION TECHNIQUE
    BORNE, GM
    BEDOU, GL
    PINAUDEAU, M
    [J]. JOURNAL OF NEUROSURGERY, 1984, 60 (01) : 88 - 93
  • [4] ATLANTO-AXIAL ARTHRODESIS BY WEDGE COMPRESSION METHOD
    BROOKS, AL
    JENKINS, EB
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03) : 279 - 284
  • [5] Atlantoaxial fusion: a biomechanical analysis of two C1-C2 fusion techniques
    Claybrooks, Roderick
    Kayanja, Mark
    Milks, Ryan
    Benzel, Edward
    [J]. SPINE JOURNAL, 2007, 7 (06) : 682 - 688
  • [6] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis
    Dickman, CA
    Sonntag, VKH
    [J]. NEUROSURGERY, 1998, 43 (02) : 275 - 280
  • [7] Gallie W.E., 1939, Am. J. Surg, V46, P495, DOI [10.1016/S0002-9610(39)90309-0, DOI 10.1016/S0002-9610(39)90309-0]
  • [8] Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients
    Gluf, WM
    Schmidt, MH
    Apfelbaum, RI
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (02) : 155 - 163
  • [9] PLATE AND SCREW FIXATION FOR ATLANTOAXIAL SUBLUXATION
    GOEL, A
    LAHERI, V
    [J]. ACTA NEUROCHIRURGICA, 1994, 129 (1-2) : 47 - 53
  • [10] Constructs incorporating intralaminar C2 screws provide rigid stability for Atlantoaxial fixation
    Gorek, J
    Acaroglu, E
    Berven, S
    Yousef, A
    Puttlitz, CM
    [J]. SPINE, 2005, 30 (13) : 1513 - 1518