IMRT FOR IMAGE-GUIDED SINGLE VOCAL CORD IRRADIATION

被引:44
作者
Osman, Sarah O. S. [1 ]
Astreinidou, Eleftheria [1 ]
de Boer, Hans C. J. [1 ]
Keskin-Cambay, Fatma [1 ]
Breedveld, Sebastiaan [1 ]
Voet, Peter [1 ]
Al-Mamgani, Abrahim [1 ]
Heijmen, Ben J. M. [1 ]
Levendag, Peter C. [1 ]
机构
[1] Dr Daniel Den Hoed Canc Ctr, Erasmus Med Ctr, Dept Radiat Oncol, NL-3008 AE Rotterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2012年 / 82卷 / 02期
关键词
Image-guided radiotherapy; Intensity-modulated radiotherapy; Early glottic carcinoma; Normal tissue sparing; Quality of life; INTENSITY-MODULATED RADIOTHERAPY; RADIATION-THERAPY; PATIENT MOTION; CANCER; LARYNX; OPTIMIZATION; CARCINOMA; QUALITY;
D O I
10.1016/j.ijrobp.2010.12.022
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We have been developing an image-guided single vocal cord irradiation technique to treat patients with stage T la glottic carcinoma. In the present study, we compared the dose coverage to the affected vocal cord and the dose delivered to the organs at risk using conventional, intensity-modulated radiotherapy (IMRT) coplanar, and IMRT non-coplanar techniques. Methods and Materials: For 10 patients, conventional treatment plans using two laterally opposed wedged 6-MV photon beams were calculated in XiO (Elekta-CMS treatment planning system). An in-house IMRT/beam angle optimization algorithm was used to obtain the coplanar and non-coplanar optimized beam angles. Using these angles, the IMRT plans were generated in Monaco (IMRT treatment planning system, Elekta-CMS) with the implemented Monte Carlo dose calculation algorithm. The organs at risk included the contralateral vocal cord, arytenoids, swallowing muscles, carotid arteries, and spinal cord. The prescription dose was 66 Gy in 33 fractions. Results: For the conventional plans and coplanar and non-coplanar IMRT plans, the population-averaged mean dose +/- standard deviation to the planning target volume was 67 +/- 1 Gy. The contralateral vocal cord dose was reduced from 66 +/- 1 Gy in the conventional plans to 39 +/- 8 Gy and 36 +/- 6 Gy in the coplanar and non-coplanar IMRT plans, respectively. IMRT consistently reduced the doses to the other organs at risk. Conclusions: Single vocal cord irradiation with IMRT resulted in good target coverage and provided significant sparing of the critical structures. This has the potential to improve the quality-of-life outcomes after RT and maintain the same local control rates. (C) 2012 Elsevier Inc.
引用
收藏
页码:989 / 997
页数:9
相关论文
共 27 条
[1]   Effect of arytenoid sparing during radiation therapy of early stage glottic carcinoma [J].
Allal, AS ;
Miralbell, R ;
Lehmann, W ;
Kurtz, JM .
RADIOTHERAPY AND ONCOLOGY, 1997, 43 (01) :63-65
[2]   Objective evaluation of the quality of voice following radiation therapy for T-1 glottic cancer [J].
Aref, A ;
Dworkin, J ;
Devi, S ;
Denton, L ;
Fontanesi, J .
RADIOTHERAPY AND ONCOLOGY, 1997, 45 (02) :149-153
[3]   MULTI-CRITERIA BEAM ANGLE IMRT OPTIMIZATION [J].
Breedveld, S. ;
Storchi, P. ;
Heijmen, B. .
RADIOTHERAPY AND ONCOLOGY, 2009, 92 :S204-S204
[4]   CAROTID-SPARING INTENSITY-MODULATED RADIOTHERAPY FOR EARLY-STAGE SQUAMOUS CELL CARCINOMA OF THE TRUE VOCAL CORD [J].
Chera, Bhishamjit S. ;
Amdur, Robert J. ;
Morris, Christopher G. ;
Mendenhall, William M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (05) :1380-1385
[5]   Radiation doses to structures within and adjacent to the larynx are correlated with long-term diet- and speech-related quality of life [J].
Dornfeld, Ken ;
Simmons, Joel R. ;
Karnell, Lucy ;
Karnell, Michael ;
Funk, Gerry ;
Yao, Min ;
Wacha, Judith ;
Zimmerman, Bridget ;
Buatti, John M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03) :750-757
[6]   Intra- and interfractional patient motion for a variety of immobilization devices [J].
Engelsman, M ;
Rosenthal, SJ ;
Michaud, SL ;
Adams, JA ;
Schneider, RJ ;
Bradley, SG ;
Flanz, JB ;
Kooy, HM .
MEDICAL PHYSICS, 2005, 32 (11) :3468-3474
[7]   Intensity-modulated radiotherapy for early larynx cancer: Is there a role? [J].
Feigenberg, Steven J. ;
Lango, Miriam ;
Nicolaou, Nicos ;
Ridge, John A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (01) :2-3
[8]   Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm [J].
Fippel, M .
MEDICAL PHYSICS, 1999, 26 (08) :1466-1475
[9]   Dosimetric validation of a commercial Monte Carlo based IMRT planning system [J].
Grofsmid, Dennis ;
Dirkx, Maarten ;
Marijnissen, Hans ;
Woudstra, Evert ;
Heijmen, Ben .
MEDICAL PHYSICS, 2010, 37 (02) :540-549
[10]   Time dependence of intrafraction patient motion assessed by repeat stereoscopic imaging [J].
Hoogeman, Mischa S. ;
Nuyttens, Joost J. ;
Levendag, Peter C. ;
Heumen, Ben J. M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02) :609-618