Homogeneous and Heterogeneous Solid State Self-Healing System

被引:1
作者
Muhamad, Noor Nabilah [1 ]
Jamil, Mohd Suzeren Md. [1 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Sci & Technol, Sch Chem Sci & Food Technol, Bangi 43600, Selangor, Malaysia
关键词
Solid state self-healing; Homogeneous blend; Heterogeneous blend; Healing efficiency; Compact tension test; DAMAGE; COMPOSITES;
D O I
10.1177/096739111602400920
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The solid state self-healing system was obtained by employing a thermosetting epoxy resin, into which a thermoplastic is dissolved. The aim of this study is to investigate the homogeneous and heterogeneous solid state self-healing system by using thermoplastics comprised of poly(bisphenol-A-co-epichlorohydrin) (PDGEBA), polyvinyl chloride (PVC), polyvinyl alcohol (PVA), polyethylene (PE) and polypropylene (PP) as healing agents. PDGEBA produced homogenous resin blend which undergone random molecule diffusion healing process. A heterogeneous resin blend composed of 8 wt.% PVC, PVA PE, and PP, yielding a "bricks and mortar" morphology wherein the epoxy phase exists as a matrix (mortar) interpenetrated with a percolating thermoplastic (bricks). The healing process in heterogeneous resin blend is attributed to volumetric thermal expansion of healing agent above its melting point in excess of epoxy brick expansion. Healing was achieved by heating the fractured resins to a specific temperature; above their glass transition temperature (Tg) which obtained from dynamic mechanical analysis (DMA) in order for diffusion process and thermal expansion to occur. The thermal properties and bonding formed in the epoxy resins were characterized by means of Fourier Transform Infrared Spectroscopy (FTIR) and dynamic mechanical thermal analysis (DMTA). Izod impact test and compact tension test were conducted to demonstrate details self-healing capability of different specimens. Results of Izod impact test are in agreement with the result of compact tension test. Under compact tension test, the healable resin with PDGEBA has the highest healing efficiency of 60% followed by PVC, PP, PE, and PVA with 39%, 37%, 28% and 21% of average percentage healing efficiencies in three healing cycle respectively. Morphological studies using optical microscope verified the fracture-healing process and morphological properties of the resins.
引用
收藏
页码:815 / 824
页数:10
相关论文
共 24 条
  • [1] Astrom B.T., 1997, Manufacturing of polymer composites
  • [2] Self-Healing Polymers and Composites
    Blaiszik, B. J.
    Kramer, S. L. B.
    Olugebefola, S. C.
    Moore, J. S.
    Sottos, N. R.
    White, S. R.
    [J]. ANNUAL REVIEW OF MATERIALS RESEARCH, VOL 40, 2010, 40 : 179 - 211
  • [3] Adhesively-bonded repairs to fibre-composite materials I: Experimental
    Charalambides, MN
    Hardouin, R
    Kinloch, AJ
    Matthews, FL
    [J]. COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 1998, 29 (11) : 1371 - 1381
  • [4] A thermally re-mendable cross-linked polymeric material
    Chen, XX
    Dam, MA
    Ono, K
    Mal, A
    Shen, HB
    Nutt, SR
    Sheran, K
    Wudl, F
    [J]. SCIENCE, 2002, 295 (5560) : 1698 - 1702
  • [5] Modification of thermosetting resins and composites through preformed polymer particles: A review
    Hayes, BS
    Seferis, JC
    [J]. POLYMER COMPOSITES, 2001, 22 (04) : 451 - 467
  • [6] A self-healing thermosetting composite material
    Hayes, S. A.
    Jones, F. R.
    Marshiya, K.
    Zhang, W.
    [J]. COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2007, 38 (04) : 1116 - 1120
  • [7] Self-healing of damage in fibre-reinforced polymer-matrix composites
    Hayes, S. A.
    Zhang, W.
    Branthwaite, M.
    Jones, F. R.
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2007, 4 (13) : 381 - 387
  • [8] A resistance-based damage location sensor for carbon-fibre composites
    Hou, L
    Hayes, SA
    [J]. SMART MATERIALS AND STRUCTURES, 2002, 11 (06) : 966 - 969
  • [9] HOY KL, 1970, J PAINT TECHNOL, V42, P76
  • [10] Jones FR, 2007, SPRINGER SER MATER S, V100, P69, DOI 10.1007/978-1-4020-6250-6_4