A Novel Activated Biochar-Based Immunosensor for Rapid Detection of E. coli O157:H7

被引:14
|
作者
Sobhan, Abdus [1 ,2 ]
Jia, Fei [1 ]
Kelso, Lisa Cooney [1 ]
Biswas, Sonatan Kumar [1 ]
Muthukumarappan, Kasiviswanathan [2 ]
Cao, Changyong [3 ,4 ]
Wei, Lin [2 ]
Li, Yanbin [1 ]
机构
[1] Univ Arkansas, Dept Biol & Agr Engn, Ctr Excellence Poultry Sci, Fayetteville, AR 72701 USA
[2] South Dakota State Univ, Dept Agr & Biosyst Engn, Brookings, SD 57007 USA
[3] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Cleveland, OH 44106 USA
[4] Louis Stokes Cleveland VA Med Ctr, Adv Platform Technol APT, Cleveland, OH 44106 USA
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 10期
关键词
electrochemical immunosensor; rapid detection; activated biochar; biosensor; Escherichia coli O157:H7; ELECTROCHEMICAL BIOSENSOR; YERSINIA-ENTEROCOLITICA; NANOPARTICLES; ELECTRODE;
D O I
10.3390/bios12100908
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
E. coli O157:H7, one of the major foodborne pathogens, can cause a significant threat to the safety of foods. The aim of this research is to develop an activated biochar-based immunosensor that can rapidly detect E. coli O157:H7 cells without incubation in pure culture. Biochar was developed from corn stalks using proprietary reactors and then activated using steam-activation treatment. The developed activated biochar presented an enhanced surface area of 830.78 m(2)/g. To develop the biosensor, the gold electrode of the sensor was first coated with activated biochar and then functionalized with streptavidin as a linker and further immobilized with biotin-labeled anti-E. coli polyclonal antibodies (pAbs). The optimum concentration of activated biochar for sensor development was determined to be 20 mg/mL. Binding of anti-E. coli pAbs with E. coli O157:H7 resulted in a significant increase in impedance amplitude from 3.5 to 8.5 k omega when compared to an only activated biochar-coated electrode. The developed immunosensor was able to detect E. coli O157:H7 cells with a limit of detection of 4 log CFU/mL without incubation. Successful binding of E. coli O157:H7 onto an activated biochar-based immunosensor was observed on the microelectrode surface in scanning electron microscopy (SEM) images.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Visual and quantitative detection of E. coli O157:H7 by coupling immunomagnetic separation and quantum dot-based paper strip
    Qiao, Zhaohui
    Cai, Qiqi
    Fu, Yingchun
    Lei, Chunyang
    Yang, Wenge
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (17) : 4417 - 4426
  • [42] Titanium dioxide-mediated resistive nanobiosensor for E. coli O157:H7
    Nadzirah, Sh.
    Hashim, U.
    Gopinath, Subash C. B.
    Parmin, N. A.
    Hamzah, Azrul Azlan
    Yu, Hung Wei
    Dee, Chang Fu
    MICROCHIMICA ACTA, 2020, 187 (04)
  • [43] Rapid electrochemical detection of polyaniline-labeled Escherichia coli O157:H7
    Setterington, Emma B.
    Alocilja, Evangelyn C.
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05) : 2208 - 2214
  • [44] Development and Application of IMSA for Rapid Detection of Enterohaemorrhage Escherichia coli O157:H7
    Wang Q.
    Xu W.
    Shi P.
    Science and Technology of Food Industry, 2021, 42 (17) : 263 - 269
  • [45] Rapid detection of Escherichia coli O157:H7 using tunneling magnetoresistance biosensor
    Wu, Yuanzhao
    Liu, Yiwei
    Zhan, Qingfeng
    Liu, J. Ping
    Li, Run-Wei
    AIP ADVANCES, 2017, 7 (05):
  • [46] Low concentration E. coli O157:H7 bacteria sensing using microfluidic MEMS biosensor
    Dastider, Shibajyoti Ghosh
    Abdullah, Amjed
    Jasim, Ibrahem
    Yuksek, Nuh S.
    Dweik, Majed
    Almasri, Mahmoud
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (12)
  • [47] Detection of E. coli O157:H7 in Complex Matrices under Varying Flow Parameters with a Robotic, Fluorometric Assay System
    Leskinen, Stephaney D.
    Schlemmer, Sarah M.
    Kearns, Elizabeth A.
    Lim, Daniel V.
    FRONTIERS IN PATHOGEN DETECTION: FROM NANOSENSORS TO SYSTEMS, 2009, 7167
  • [48] Conductometric Immunosensor for Escherichia coli O157:H7 Detection Based on Polyaniline/Zinc Oxide (PANI/ZnO) Nanocomposite
    Mutlaq, Sawsan
    Albiss, Borhan
    Al-Nabulsi, Anas A.
    Jaradat, Ziad W.
    Olaimat, Amin N.
    Khalifeh, Mohammad S.
    Osaili, Tareq
    Ayyash, Mutamed M.
    Holley, Richard A.
    POLYMERS, 2021, 13 (19)
  • [49] Electrochemical immunosensor assay (EIA) for sensitive detection of E. coli O157:H7 with signal amplification on a SG-PEDOT-AuNPs electrode interface
    Guo, Yuna
    Wang, Yu
    Liu, Su
    Yu, Jinghua
    Wang, Hongzhi
    Cui, Min
    Huang, Jiadong
    ANALYST, 2015, 140 (02) : 551 - 559
  • [50] A homogeneous magnetic bead-based impedance immunosensor for highly sensitive detection of Escherichia coli O157:H7
    Wang, Shujun
    Sun, Chongyun
    Hu, Qiushi
    Li, Shuang
    Wang, Chengbin
    Wang, Peng
    Zhou, Lei
    BIOCHEMICAL ENGINEERING JOURNAL, 2020, 156 (156)