A Novel Activated Biochar-Based Immunosensor for Rapid Detection of E. coli O157:H7

被引:14
|
作者
Sobhan, Abdus [1 ,2 ]
Jia, Fei [1 ]
Kelso, Lisa Cooney [1 ]
Biswas, Sonatan Kumar [1 ]
Muthukumarappan, Kasiviswanathan [2 ]
Cao, Changyong [3 ,4 ]
Wei, Lin [2 ]
Li, Yanbin [1 ]
机构
[1] Univ Arkansas, Dept Biol & Agr Engn, Ctr Excellence Poultry Sci, Fayetteville, AR 72701 USA
[2] South Dakota State Univ, Dept Agr & Biosyst Engn, Brookings, SD 57007 USA
[3] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Cleveland, OH 44106 USA
[4] Louis Stokes Cleveland VA Med Ctr, Adv Platform Technol APT, Cleveland, OH 44106 USA
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 10期
关键词
electrochemical immunosensor; rapid detection; activated biochar; biosensor; Escherichia coli O157:H7; ELECTROCHEMICAL BIOSENSOR; YERSINIA-ENTEROCOLITICA; NANOPARTICLES; ELECTRODE;
D O I
10.3390/bios12100908
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
E. coli O157:H7, one of the major foodborne pathogens, can cause a significant threat to the safety of foods. The aim of this research is to develop an activated biochar-based immunosensor that can rapidly detect E. coli O157:H7 cells without incubation in pure culture. Biochar was developed from corn stalks using proprietary reactors and then activated using steam-activation treatment. The developed activated biochar presented an enhanced surface area of 830.78 m(2)/g. To develop the biosensor, the gold electrode of the sensor was first coated with activated biochar and then functionalized with streptavidin as a linker and further immobilized with biotin-labeled anti-E. coli polyclonal antibodies (pAbs). The optimum concentration of activated biochar for sensor development was determined to be 20 mg/mL. Binding of anti-E. coli pAbs with E. coli O157:H7 resulted in a significant increase in impedance amplitude from 3.5 to 8.5 k omega when compared to an only activated biochar-coated electrode. The developed immunosensor was able to detect E. coli O157:H7 cells with a limit of detection of 4 log CFU/mL without incubation. Successful binding of E. coli O157:H7 onto an activated biochar-based immunosensor was observed on the microelectrode surface in scanning electron microscopy (SEM) images.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Magnetoresistive immunosensor for the detection of Escherichia coli O157:H7 including a microfluidic network
    Mujika, M.
    Arana, S.
    Castano, E.
    Tijero, M.
    Vilares, R.
    Ruano-Lopez, J. M.
    Cruz, A.
    Sainz, L.
    Berganza, J.
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (05) : 1253 - 1258
  • [22] Rapid detection of E. coli O157:H7 by a novel access with combination of improved sample preparation and real-time PCR
    Jin-Hee Kim
    Se-Wook Oh
    Food Science and Biotechnology, 2020, 29 : 1149 - 1157
  • [23] Rapid detection of E. coli O157:H7 by a novel access with combination of improved sample preparation and real-time PCR
    Kim, Jin-Hee
    Oh, Se-Wook
    FOOD SCIENCE AND BIOTECHNOLOGY, 2020, 29 (08) : 1149 - 1157
  • [24] Detection of escherichia coli O157:H7 using interdigitated array microelectrode-based immunosensor
    Wang Y.
    Wang R.
    Li Y.
    Srinivasan B.
    Tung S.
    Wang H.
    Slavik M.F.
    Griffis C.L.
    Biological Engineering, 2010, 2 (02): : 49 - 62
  • [25] Foodborne Pathogen Screening Using Magneto-fluorescent Nanosensor: Rapid Detection of E. Coli O157:H7
    Shelby, Tyler
    Sulthana, Shoukath
    McAfee, James
    Banerjee, Tuhina
    Santra, Santimukul
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (127):
  • [26] Trace Detection of E. coli O157:H7 Cells by an Au Nanoparticle- Based SERS Aptasensor
    Tian, Cheng
    Zhao, Lei
    Qi, Guoliang
    Zhang, Shusheng
    ACS APPLIED NANO MATERIALS, 2023, 6 (02) : 1386 - 1394
  • [27] Surface plasmon resonance based immunosensing of E. coli O157:H7 in apple juice
    Subramanian, A. S.
    Irudayaraj, J. M.
    TRANSACTIONS OF THE ASABE, 2006, 49 (04) : 1257 - 1262
  • [28] Rapid detection of Escherichia coli O157:H7 spiked into food matrices
    Shriver-Lake, Lisa C.
    Turner, Stephanie
    Taitt, Chris R.
    ANALYTICA CHIMICA ACTA, 2007, 584 (01) : 66 - 71
  • [29] A novel biosensor for Escherichia coli O157:H7 based on fluorescein-releasable biolabels
    Hu, Rong-Rong
    Yin, Zheng-Zhi
    Zeng, Yan-Bo
    Zhang, Jian
    Liu, Hai-Qing
    Shao, Yong
    Ren, Shi-Bin
    Li, Lei
    BIOSENSORS & BIOELECTRONICS, 2016, 78 : 31 - 36
  • [30] Subtractive Inhibition Assay for the Detection of E. coli O157:H7 Using Surface Plasmon Resonance
    Wang, Yixian
    Ye, Zunzhong
    Si, Chengyan
    Ying, Yibin
    SENSORS, 2011, 11 (03): : 2728 - 2739