A Novel Activated Biochar-Based Immunosensor for Rapid Detection of E. coli O157:H7

被引:14
|
作者
Sobhan, Abdus [1 ,2 ]
Jia, Fei [1 ]
Kelso, Lisa Cooney [1 ]
Biswas, Sonatan Kumar [1 ]
Muthukumarappan, Kasiviswanathan [2 ]
Cao, Changyong [3 ,4 ]
Wei, Lin [2 ]
Li, Yanbin [1 ]
机构
[1] Univ Arkansas, Dept Biol & Agr Engn, Ctr Excellence Poultry Sci, Fayetteville, AR 72701 USA
[2] South Dakota State Univ, Dept Agr & Biosyst Engn, Brookings, SD 57007 USA
[3] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Cleveland, OH 44106 USA
[4] Louis Stokes Cleveland VA Med Ctr, Adv Platform Technol APT, Cleveland, OH 44106 USA
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 10期
关键词
electrochemical immunosensor; rapid detection; activated biochar; biosensor; Escherichia coli O157:H7; ELECTROCHEMICAL BIOSENSOR; YERSINIA-ENTEROCOLITICA; NANOPARTICLES; ELECTRODE;
D O I
10.3390/bios12100908
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
E. coli O157:H7, one of the major foodborne pathogens, can cause a significant threat to the safety of foods. The aim of this research is to develop an activated biochar-based immunosensor that can rapidly detect E. coli O157:H7 cells without incubation in pure culture. Biochar was developed from corn stalks using proprietary reactors and then activated using steam-activation treatment. The developed activated biochar presented an enhanced surface area of 830.78 m(2)/g. To develop the biosensor, the gold electrode of the sensor was first coated with activated biochar and then functionalized with streptavidin as a linker and further immobilized with biotin-labeled anti-E. coli polyclonal antibodies (pAbs). The optimum concentration of activated biochar for sensor development was determined to be 20 mg/mL. Binding of anti-E. coli pAbs with E. coli O157:H7 resulted in a significant increase in impedance amplitude from 3.5 to 8.5 k omega when compared to an only activated biochar-coated electrode. The developed immunosensor was able to detect E. coli O157:H7 cells with a limit of detection of 4 log CFU/mL without incubation. Successful binding of E. coli O157:H7 onto an activated biochar-based immunosensor was observed on the microelectrode surface in scanning electron microscopy (SEM) images.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A Preliminary Investigation on MEMS Based Immunosensor for E. coli O157:H7 Detection
    Abu Bakar, M. H.
    Ibrahim, M. H.
    Kassim, N. M.
    Mohammad, A. B.
    2009 IEEE 9TH MALAYSIA INTERNATIONAL CONFERENCE ON COMMUNICATIONS (MICC), 2009, : 51 - 54
  • [2] Separation and detection of E. coli O157:H7 using a SERS-based microfluidic immunosensor
    Asgari, Sara
    Dhital, Rajiv
    Aghvami, S. Ali
    Mustapha, Azlin
    Zhang, Yi
    Lin, Mengshi
    MICROCHIMICA ACTA, 2022, 189 (03)
  • [3] Amperometric immunosensor for the detection of Escherichia coli O157:H7 in food specimens
    Li, Yan
    Cheng, Ping
    Gong, Junhua
    Fang, Lichao
    Deng, Jun
    Liang, Wenbin
    Zheng, Junsong
    ANALYTICAL BIOCHEMISTRY, 2012, 421 (01) : 227 - 233
  • [4] Electroanalytical Platform for Rapid E. coli O157:H7 Detection in Water Samples
    Mishra, Kundan Kumar
    Dhamu, Vikram Narayanan
    Jophy, Chesna
    Muthukumar, Sriram
    Prasad, Shalini
    BIOSENSORS-BASEL, 2024, 14 (06):
  • [5] Dendrimeric biosensor for detection of E. coli O157:H7 in diet
    Shende, Pravin
    Kasture, Pooja
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2020, 10 (02): : 5128 - 5131
  • [6] A sensitive electrochemical strategy via multiple amplification reactions for the detection of E. coli O157: H7
    Li, Yan
    Liu, Huamin
    Huang, Hui
    Deng, Jun
    Fang, Lichao
    Luo, Jing
    Zhang, Shu
    Huang, Jian
    Liang, Wenbin
    Zheng, Junsong
    BIOSENSORS & BIOELECTRONICS, 2020, 147
  • [7] Electrochemical biosensors for rapid detection of Escherichia coli O157:H7
    Xu, Meng
    Wang, Ronghui
    Li, Yanbin
    TALANTA, 2017, 162 : 511 - 522
  • [8] Evaluation of different micro/nanobeads used as amplifiers in QCM immunosensor for more sensitive detection of E. coli O157:H7
    Jiang, Xuesong
    Wang, Ronghui
    Wang, Yun
    Su, Xiaoli
    Ying, Yibin
    Wang, Jianping
    Li, Yanbin
    BIOSENSORS & BIOELECTRONICS, 2011, 29 (01) : 23 - 28
  • [9] A comprehensive review of detection methods for Escherichia coli O157:H7
    Bai, Zhuangzhuang
    Xu, Xianbao
    Wang, Cong
    Wang, Tan
    Sun, Chuanyu
    Liu, Shuangxi
    Li, Daoliang
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 152
  • [10] Liposome-based microcapillary immunosensor for detection of Escherichia coli O157:H7
    Ho, JAA
    Hsu, HW
    Huang, MR
    ANALYTICAL BIOCHEMISTRY, 2004, 330 (02) : 342 - 349