The Utilization of Metal Augments Allows Better Biomechanical Reconstruction of the Hip in Revision Total Hip Arthroplasty With Severe Acetabular Defects: A Comparative Study

被引:19
作者
Zhou, Baochun [1 ]
Zhou, Yixin [1 ]
Yang, Dejin [1 ]
Tang, Hao [1 ]
Shao, Hongyi [1 ]
Huang, Yong [1 ]
机构
[1] Peking Univ, Dept Orthopaed Surg, Beijing Jishuitan Hosp, Clin Coll 4, 31 Xinjiekou East St, Beijing 100035, Peoples R China
关键词
revision total hip arthroplasty; biomechanical reconstruction; augment; jumbo cup; center of rotation; head-cup difference; ABDUCTOR MUSCLE STRENGTH; LEG-LENGTH DISCREPANCY; JUMBO CUPS; FOLLOW-UP; PROTRUSIO-ACETABULI; SUPERIOR PLACEMENT; CENTER ELEVATION; FEMORAL OFFSET; IIIA DEFECTS; BONE LOSS;
D O I
10.1016/j.arth.2018.08.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Reconstructing the normal hip biomechanics is important for a successful revision total hip arthroplasty (THA). Little is known about whether using metal augments in revision THA is biomechanically superior to traditional techniques. Methods: A retrospective review was conducted on 74 consecutive THAs revised using metal augments with a cementless hemispherical cup and 77 consecutive THAs revised using the jumbo cup, all with a minimum 2-year follow-up. Biomechanical parameters were measured before and immediately after the revision. Radiological and clinical outcomes at follow-ups were also evaluated. Results: The metal augment group had a reconstructed center of rotation (COR) that was 6.5 mm closer to the anatomic COR in height (P < .001), had 3.6 m smaller cup size (P < .001), and had 5.7 mm less head-cup difference (P < .001). Moreover, there was a reconstructed COR that was much closer to the anatomic COR (vertical distance: 1.8 vs 14.1 mm, P < .001; horizontal distance: -2.1 vs 7.9 mm, P = .013), had 4.1 mm greater femoral offset (P = .006), and had 8 mm less leg length discrepancy (P = .035) in the subgroup of Paprosky type III bone defects when compared to the jumbo cup group. All cup-augment constructs were radiologically stable with a higher mean postoperative Harris Hip Score (P = .012). One jumbo cup was radiologically unstable. Conclusion: In revision THA, utilizing metal augments helps to restore the COR position more precisely, avoid using a larger cup, reduce head-cup difference, rebuild femoral offset, and decrease leg length discrepancy, particularly with Paprosky type III bone defects. Moreover, it provides satisfactory radiological and clinical outcomes in the short term. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:3724 / 3733
页数:10
相关论文
共 50 条
  • [41] Options for managing severe acetabular bone loss in revision hip arthroplasty. A systematic review
    Jain, Sameer
    Grogan, Richard J.
    Giannoudis, Peter V.
    HIP INTERNATIONAL, 2014, 24 (02) : 109 - 122
  • [42] Acetabular reconstruction with impaction bone grafting and cemented polyethylene socket in total hip revision arthroplasty
    Kostensalo, I.
    Seppanen, M.
    Virolainen, P.
    Mokka, J.
    Koivisto, M.
    Makela, K. T.
    SCANDINAVIAN JOURNAL OF SURGERY, 2015, 104 (04) : 267 - 272
  • [43] Jumbo cups for repair of moderate-to-severe acetabular bone defects during revision of total hip arthroplasty: medium-term outcomes
    An, Senbo
    Hu, Huiyu
    Liu, Yuwei
    Hu, Yihe
    Xie, Jie
    Wang, Long
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (05): : 4829 - 4835
  • [44] Reconstruction options and outcomes for acetabular bone loss in revision hip arthroplasty
    Mancino, Fabio
    Cacciola, Giorgio
    Di Matteo, Vincenzo
    De Marco, Davide
    Greenberg, Alexander
    Perisano, Carlo
    Malahias, M. A.
    Sculco, Peter K.
    Maccauro, Giulio
    De Martino, Ivan
    ORTHOPEDIC REVIEWS, 2020, 12 : 1 - 7
  • [45] Acetabular Bone Loss in Revision Total Hip Arthroplasty: Evaluation and Management
    Sheth, Neil P.
    Nelson, Charles L.
    Springer, Bryan D.
    Fehring, Thomas K.
    Paprosky, Wayne G.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2013, 21 (03) : 128 - 139
  • [46] Custom-made acetabular implants in revision total hip arthroplasty
    von Lewinski, Gabriela
    ORTHOPADE, 2020, 49 (05): : 417 - 423
  • [47] Acetabular cup positioning in revision total hip arthroplasty with Paprosky type III acetabular defects: Martell radiographic analysis
    Choi, Ho-Rim
    Anderson, David
    Foster, Scott
    Beal, Matthew
    Lee, Jo Ann
    Barr, Christopher
    Malchau, Henrik
    McCarthy, Joseph
    Kwon, Young-Min
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (10) : 1905 - 1910
  • [48] Mechanical Stability of Novel Highly Porous Metal Acetabular Components in Revision Total Hip Arthroplasty
    Meneghini, R. Michael
    Meyer, Christopher
    Buckley, Christine A.
    Hanssen, Arlen D.
    Lewallen, David G.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (03) : 337 - 341
  • [49] Application of Acetabular Reinforcement Ring with Hook for Correction of Segmental Acetabular Rim Defects during Total Hip Arthroplasty Revision
    Xiao, Jianlin
    Zhao, Xin
    Wang, Yiming
    Yang, Yuhui
    Zhao, Jianhui
    Gao, Zhongli
    Zuo, Jianlin
    JOURNAL OF BIONIC ENGINEERING, 2018, 15 (01) : 154 - 159
  • [50] Oblong Acetabular Cup, Type TC, for Revision Total Hip Arthroplasty
    Trc, T.
    Stastny, E.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2012, 79 (06) : 506 - 511