Three-dimensional ultrasound scanning

被引:95
作者
Fenster, Aaron [1 ,2 ,3 ,4 ]
Parraga, Grace [1 ,2 ,3 ,4 ]
Bax, Jeff [1 ,3 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, Imaging Res Labs, London, ON, Canada
[2] Univ Western Ontario, Dept Med Imaging, London, ON, Canada
[3] Univ Western Ontario, Grad Program Biomed Engn, London, ON, Canada
[4] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
基金
加拿大健康研究院;
关键词
three-dimensional ultrasound scanning; radiographic imaging; computed tomography; CAROTID PLAQUE VOLUME; FREEHAND 3-D ULTRASOUND; PROSTATE BOUNDARY SEGMENTATION; MAXIMUM INTENSITY PROJECTION; AMERICAN-HEART-ASSOCIATION; CORONARY-ARTERY DISEASE; INTIMA-MEDIA THICKNESS; IN-VITRO; CALIBRATION METHOD; IMAGING-SYSTEM;
D O I
10.1098/rsfs.2011.0019
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The past two decades have witnessed developments of new imaging techniques that provide three-dimensional images about the interior of the human body in a manner never before available. Ultrasound (US) imaging is an important cost-effective technique used routinely in the management of a number of diseases. However, two-dimensional viewing of three-dimensional anatomy, using conventional two-dimensional US, limits our ability to quantify and visualize the anatomy and guide therapy, because multiple two-dimensional images must be integrated mentally. This practice is inefficient, and may lead to variability and incorrect diagnoses. Investigators and companies have addressed these limitations by developing three-dimensional US techniques. Thus, in this paper, we review the various techniques that are in current use in three-dimensional US imaging systems, with a particular emphasis placed on the geometric accuracy of the generation of three-dimensional images. The principles involved in three-dimensional US imaging are then illustrated with a diagnostic and an interventional application: (i) three-dimensional carotid US imaging for quantification and monitoring of carotid atherosclerosis and (ii) three-dimensional US-guided prostate biopsy.
引用
收藏
页码:503 / 519
页数:17
相关论文
共 116 条
  • [1] 3D ultrasound measurement of change in carotid plaque volume - A tool for rapid evaluation of new therapies
    Ainsworth, CD
    Blake, CC
    Tamayo, A
    Beletsky, V
    Fenster, A
    Spence, JD
    [J]. STROKE, 2005, 36 (09) : 1904 - 1909
  • [2] Carotid artery intima-media thickness measured by ultrasonography in normal clinical practice correlates well with atherosclerosis risk factors
    Baldassarre, D
    Amato, M
    Bondioli, A
    Sirtori, CR
    Tremoli, E
    [J]. STROKE, 2000, 31 (10) : 2426 - 2430
  • [3] Measurement of carotid artery intima-media thickness in dyslipidemic patients increases the power of traditional risk factors to predict cardiovascular events
    Baldassarre, Damiano
    Amato, Mauro
    Pustina, Linda
    Castelnuovo, Samuela
    Sanvito, Silvia
    Gerosa, Lorenzo
    Veglia, Fabrizio
    Keidar, Shlomo
    Tremoli, Elena
    Sirtori, Cesare R.
    [J]. ATHEROSCLEROSIS, 2007, 191 (02) : 403 - 408
  • [4] Ballantyne C, 2002, AM J CARDIOL, V89, p15B
  • [5] BAMBER JC, 1992, P SOC PHOTO-OPT INS, V1808, P651, DOI 10.1117/12.131117
  • [6] Psychological stress and the progression of carotid artery disease
    Barnett, PA
    Spence, JD
    Manuck, SB
    Jennings, JR
    [J]. JOURNAL OF HYPERTENSION, 1997, 15 (01) : 49 - 55
  • [7] Mechanically assisted 3D ultrasound guided prostate biopsy system
    Bax, Jeffrey
    Cool, Derek
    Gardi, Lori
    Knight, Kerry
    Smith, David
    Montreuil, Jacques
    Sherebrin, Shi
    Romagnoli, Cesare
    Fenster, Aaron
    [J]. MEDICAL PHYSICS, 2008, 35 (12) : 5397 - 5410
  • [8] Three- and 4-dimensional ultrasound in obstetrics and gynecology - Proceedings of the American Institute of Ultrasound in Medicine Consensus Conference
    Benacerraf, BR
    Benson, CB
    Abuhamad, AZ
    Copel, JA
    Abramowicz, JS
    DeVore, GR
    Doubilet, PM
    Lee, W
    Lev-Toaff, AS
    Merz, E
    Nelson, TR
    O'Neill, MJ
    Parsons, AK
    Platt, LD
    Pretorius, DH
    Timor-Tritsch, IE
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (12) : 1587 - 1597
  • [9] Variability and accuracy of measurements of prostate brachytherapy seed position in vitro using three-dimensional ultrasound:: An intra- and inter-observer study
    Blake, CC
    Elliot, TL
    Slomka, PJ
    Downey, DB
    Fenster, A
    [J]. MEDICAL PHYSICS, 2000, 27 (12) : 2788 - 2795
  • [10] Three-dimensional ultrasound-guided robotic needle placement: an experimental evacuation
    Boctor, Emad M.
    Choti, Michael A.
    Burdette, Everette C.
    Webster, Robert J., III
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2008, 4 (02) : 180 - 191