Three-dimensional ultrasound scanning

被引:96
作者
Fenster, Aaron [1 ,2 ,3 ,4 ]
Parraga, Grace [1 ,2 ,3 ,4 ]
Bax, Jeff [1 ,3 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, Imaging Res Labs, London, ON, Canada
[2] Univ Western Ontario, Dept Med Imaging, London, ON, Canada
[3] Univ Western Ontario, Grad Program Biomed Engn, London, ON, Canada
[4] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
基金
加拿大健康研究院;
关键词
three-dimensional ultrasound scanning; radiographic imaging; computed tomography; CAROTID PLAQUE VOLUME; FREEHAND 3-D ULTRASOUND; PROSTATE BOUNDARY SEGMENTATION; MAXIMUM INTENSITY PROJECTION; AMERICAN-HEART-ASSOCIATION; CORONARY-ARTERY DISEASE; INTIMA-MEDIA THICKNESS; IN-VITRO; CALIBRATION METHOD; IMAGING-SYSTEM;
D O I
10.1098/rsfs.2011.0019
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The past two decades have witnessed developments of new imaging techniques that provide three-dimensional images about the interior of the human body in a manner never before available. Ultrasound (US) imaging is an important cost-effective technique used routinely in the management of a number of diseases. However, two-dimensional viewing of three-dimensional anatomy, using conventional two-dimensional US, limits our ability to quantify and visualize the anatomy and guide therapy, because multiple two-dimensional images must be integrated mentally. This practice is inefficient, and may lead to variability and incorrect diagnoses. Investigators and companies have addressed these limitations by developing three-dimensional US techniques. Thus, in this paper, we review the various techniques that are in current use in three-dimensional US imaging systems, with a particular emphasis placed on the geometric accuracy of the generation of three-dimensional images. The principles involved in three-dimensional US imaging are then illustrated with a diagnostic and an interventional application: (i) three-dimensional carotid US imaging for quantification and monitoring of carotid atherosclerosis and (ii) three-dimensional US-guided prostate biopsy.
引用
收藏
页码:503 / 519
页数:17
相关论文
共 116 条
[1]   3D ultrasound measurement of change in carotid plaque volume - A tool for rapid evaluation of new therapies [J].
Ainsworth, CD ;
Blake, CC ;
Tamayo, A ;
Beletsky, V ;
Fenster, A ;
Spence, JD .
STROKE, 2005, 36 (09) :1904-1909
[2]   Carotid artery intima-media thickness measured by ultrasonography in normal clinical practice correlates well with atherosclerosis risk factors [J].
Baldassarre, D ;
Amato, M ;
Bondioli, A ;
Sirtori, CR ;
Tremoli, E .
STROKE, 2000, 31 (10) :2426-2430
[3]   Measurement of carotid artery intima-media thickness in dyslipidemic patients increases the power of traditional risk factors to predict cardiovascular events [J].
Baldassarre, Damiano ;
Amato, Mauro ;
Pustina, Linda ;
Castelnuovo, Samuela ;
Sanvito, Silvia ;
Gerosa, Lorenzo ;
Veglia, Fabrizio ;
Keidar, Shlomo ;
Tremoli, Elena ;
Sirtori, Cesare R. .
ATHEROSCLEROSIS, 2007, 191 (02) :403-408
[4]  
Ballantyne C, 2002, AM J CARDIOL, V89, p15B
[5]  
BAMBER JC, 1992, P SOC PHOTO-OPT INS, V1808, P651, DOI 10.1117/12.131117
[6]   Psychological stress and the progression of carotid artery disease [J].
Barnett, PA ;
Spence, JD ;
Manuck, SB ;
Jennings, JR .
JOURNAL OF HYPERTENSION, 1997, 15 (01) :49-55
[7]   Mechanically assisted 3D ultrasound guided prostate biopsy system [J].
Bax, Jeffrey ;
Cool, Derek ;
Gardi, Lori ;
Knight, Kerry ;
Smith, David ;
Montreuil, Jacques ;
Sherebrin, Shi ;
Romagnoli, Cesare ;
Fenster, Aaron .
MEDICAL PHYSICS, 2008, 35 (12) :5397-5410
[8]   Three- and 4-dimensional ultrasound in obstetrics and gynecology - Proceedings of the American Institute of Ultrasound in Medicine Consensus Conference [J].
Benacerraf, BR ;
Benson, CB ;
Abuhamad, AZ ;
Copel, JA ;
Abramowicz, JS ;
DeVore, GR ;
Doubilet, PM ;
Lee, W ;
Lev-Toaff, AS ;
Merz, E ;
Nelson, TR ;
O'Neill, MJ ;
Parsons, AK ;
Platt, LD ;
Pretorius, DH ;
Timor-Tritsch, IE .
JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (12) :1587-1597
[9]   Variability and accuracy of measurements of prostate brachytherapy seed position in vitro using three-dimensional ultrasound:: An intra- and inter-observer study [J].
Blake, CC ;
Elliot, TL ;
Slomka, PJ ;
Downey, DB ;
Fenster, A .
MEDICAL PHYSICS, 2000, 27 (12) :2788-2795
[10]   Three-dimensional ultrasound-guided robotic needle placement: an experimental evacuation [J].
Boctor, Emad M. ;
Choti, Michael A. ;
Burdette, Everette C. ;
Webster, Robert J., III .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2008, 4 (02) :180-191