Can Dual-energy CT Evaluate Contrast Enhancement of Ground-glass Attenuation? Phantom and Preliminary Clinical Studies

被引:31
|
作者
Kawai, Tatsuya [1 ]
Shibamoto, Yuta [1 ]
Hara, Masaki [1 ]
Arakawa, Toshinao [1 ]
Nagai, Keiichi [1 ]
Ohashi, Kazuya [2 ]
机构
[1] Nagoya City Univ, Grad Sch Med Sci, Dept Radiol, Mizuho Ku, Nagoya, Aichi 4678601, Japan
[2] Nagoya City Univ, Grad Sch Med Sci, Dept Cent Radiol, Mizuho Ku, Nagoya, Aichi 4678601, Japan
关键词
Dual energy; computed tomography; pulmonary nodule; iodine; contrast media; SOLITARY PULMONARY NODULES; BRONCHIOLOALVEOLAR CARCINOMA; COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; STONE COMPOSITION; MULTIDETECTOR CT; OPACITIES; DIFFERENTIATION; MULTICENTER;
D O I
10.1016/j.acra.2010.12.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Evaluation of contrast enhancement of pulmonary lesions with ground-glass attenuation (GGA) is difficult with conventional techniques but might be possible using contrast-mapping images (CMIs) obtained by dual-energy computed tomography. To address this issue, a phantom study was conducted, and this technique was then applied to clinical cases. Materials and Methods: Phantoms made of agarose gel and those made of hollow resin clay, containing various concentrations of iodine or calcium, were used to simulate soft tissue and GGA, respectively. They were scanned using a dual-energy computed tomographic scanner, and the relationship between iodine concentration and calculated iodine value on CMIs was examined. The influence of calcium was also evaluated. In addition, contrast enhancement of 24 GGA lesions was evaluated on CMIs. Results: There was a good correlation between iodine value and iodine concentration in the soft-tissue models (r(2) = 0.996). In the GGA models, the former tended to exceed the latter when default parameters for calculating CMIs were used, but this could be corrected by modifying the parameters (r(2) = 0.998). The iodine value increased with calcium concentration in both models. On CMIs, contrast enhancement was visible in 22 adenocarcinomas but not in a pulmonary hemorrhage and an inflammatory change. Conclusions: Dual-energy computed tomography can evaluate contrast enhancement of GGA lesions.
引用
收藏
页码:682 / 689
页数:8
相关论文
共 50 条
  • [41] Investigating new CT contrast agents: a phantom study exploring quantification and differentiation methods for high-Z elements using dual-energy CT
    Todd C. Soesbe
    Yin Xi
    Khaled Nasr
    John R. Leyendecker
    Robert E. Lenkinski
    Matthew A. Lewis
    European Radiology, 2021, 31 : 8060 - 8067
  • [42] Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage
    Yoshiyuki Watanabe
    Akio Tsukabe
    Yuki Kunitomi
    Mitsuo Nishizawa
    Atsuko Arisawa
    Hisashi Tanaka
    Kazuhisa Yoshiya
    Takeshi Shimazu
    Noriyuki Tomiyama
    Neuroradiology, 2014, 56 : 291 - 295
  • [43] Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage
    Watanabe, Yoshiyuki
    Tsukabe, Akio
    Kunitomi, Yuki
    Nishizawa, Mitsuo
    Arisawa, Atsuko
    Tanaka, Hisashi
    Yoshiya, Kazuhisa
    Shimazu, Takeshi
    Tomiyama, Noriyuki
    NEURORADIOLOGY, 2014, 56 (04) : 291 - 295
  • [44] Editorial Comment: Can Dual-Energy CT Improve Adrenal Nodule Characterization on Single-Phase Contrast-Enhanced CT?
    Stuhlfaut, Joshua W.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (05) : 704 - 704
  • [45] An adult and pediatric size-based contrast administration reduction phantom study for single and dual-energy CT through preservation of contrast-to-noise ratio
    Wang, Jia
    Duan, Xinhui
    Mahmood, Usman
    Mckenney, Sarah Eva
    Brady, Samuel Loren
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (05):
  • [46] Contrast-Enhanced Dual-Energy CT of Gastrointestinal Stromal Tumors Is Iodine-Related Attenuation a Potential Indicator of Tumor Response?
    Apfaltrer, Paul
    Meyer, Mathias
    Meier, Caroline
    Henzler, Thomas
    Barraza, John M., Jr.
    Dinter, Dietmar J.
    Hohenberger, Peter
    Schoepf, U. Joseph
    Schoenberg, Stefan O.
    Fink, Christian
    INVESTIGATIVE RADIOLOGY, 2012, 47 (01) : 65 - 70
  • [47] Potential of spectral imaging generated by contrast-enhanced dual-energy CT for lung cancer histopathological classification - A preliminary study
    Sasaki, Tomoaki
    Oda, Shioto
    Kuno, Hirofumi
    Hiyama, Takashi
    Taki, Tetsuro
    Takahashi, Shugo
    Ishii, Genichiro
    Tsuboi, Masahiro
    Kobayashi, Tatsushi
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2025, 14
  • [48] Clinical Value of Dual-energy CT in Detection of Pancreatic Adenocarcinoma: Investigation of the Best Pancreatic Tumor Contrast to Noise Ratio
    Yong-lan He
    Da-ming Zhang
    Hua-dan Xue
    Zheng-yu Jin
    Chinese Medical Sciences Journal, 2012, 27 (04) : 207 - 212
  • [49] Toward Biphasic Computed Tomography (CT) Enteric Contrast: Material Classification of Luminal Bismuth and Mural Iodine in a Small-Bowel Phantom Using Dual-Energy CT
    Qu, Mingliang
    Ehman, Eric
    Fletcher, Joel G.
    Huprich, James E.
    Hara, Amy K.
    Silva, Alvin C.
    Farrugia, Gianrico
    Limburg, Paul
    McCollough, Cynthia H.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) : 554 - 559
  • [50] Iodine quantification with dual-energy CT: phantom study and preliminary experience with VX2 residual tumour in rabbits after radiofrequency ablation
    Li, Y.
    Shi, G.
    Wang, S.
    Wang, S.
    Wu, R.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1029):