Can Dual-energy CT Evaluate Contrast Enhancement of Ground-glass Attenuation? Phantom and Preliminary Clinical Studies

被引:31
|
作者
Kawai, Tatsuya [1 ]
Shibamoto, Yuta [1 ]
Hara, Masaki [1 ]
Arakawa, Toshinao [1 ]
Nagai, Keiichi [1 ]
Ohashi, Kazuya [2 ]
机构
[1] Nagoya City Univ, Grad Sch Med Sci, Dept Radiol, Mizuho Ku, Nagoya, Aichi 4678601, Japan
[2] Nagoya City Univ, Grad Sch Med Sci, Dept Cent Radiol, Mizuho Ku, Nagoya, Aichi 4678601, Japan
关键词
Dual energy; computed tomography; pulmonary nodule; iodine; contrast media; SOLITARY PULMONARY NODULES; BRONCHIOLOALVEOLAR CARCINOMA; COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; STONE COMPOSITION; MULTIDETECTOR CT; OPACITIES; DIFFERENTIATION; MULTICENTER;
D O I
10.1016/j.acra.2010.12.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Evaluation of contrast enhancement of pulmonary lesions with ground-glass attenuation (GGA) is difficult with conventional techniques but might be possible using contrast-mapping images (CMIs) obtained by dual-energy computed tomography. To address this issue, a phantom study was conducted, and this technique was then applied to clinical cases. Materials and Methods: Phantoms made of agarose gel and those made of hollow resin clay, containing various concentrations of iodine or calcium, were used to simulate soft tissue and GGA, respectively. They were scanned using a dual-energy computed tomographic scanner, and the relationship between iodine concentration and calculated iodine value on CMIs was examined. The influence of calcium was also evaluated. In addition, contrast enhancement of 24 GGA lesions was evaluated on CMIs. Results: There was a good correlation between iodine value and iodine concentration in the soft-tissue models (r(2) = 0.996). In the GGA models, the former tended to exceed the latter when default parameters for calculating CMIs were used, but this could be corrected by modifying the parameters (r(2) = 0.998). The iodine value increased with calcium concentration in both models. On CMIs, contrast enhancement was visible in 22 adenocarcinomas but not in a pulmonary hemorrhage and an inflammatory change. Conclusions: Dual-energy computed tomography can evaluate contrast enhancement of GGA lesions.
引用
收藏
页码:682 / 689
页数:8
相关论文
共 50 条
  • [1] Dual-energy CT-based radiomics for predicting invasiveness of lung adenocarcinoma appearing as ground-glass nodules
    Zheng, Yuting
    Han, Xiaoyu
    Jia, Xi
    Ding, Chengyu
    Zhang, Kailu
    Li, Hanting
    Cao, Xuexiang
    Zhang, Xiaohui
    Zhang, Xin
    Shi, Heshui
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [2] Influence of contrast medium on tophus detection using dual-energy CT: phantom study and clinical illustration
    Kotlyarov, Maximilian
    Mews, Jurgen
    Ulas, Sevtap Tugce
    Ziegeler, Katharina
    Hamm, Bernd
    Diekhoff, Torsten
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [3] Influence of contrast medium on tophus detection using dual-energy CT: phantom study and clinical illustration
    Maximilian Kotlyarov
    Jürgen Mews
    Sevtap Tugce Ulas
    Katharina Ziegeler
    Bernd Hamm
    Torsten Diekhoff
    European Radiology Experimental, 7
  • [4] Intermanufacturer Comparison of Dual-Energy CT Iodine Quantification and Monochromatic Attenuation: A Phantom Study
    Jacobsen, Megan C.
    Schellingerhout, Dawid
    Wood, Cayla A.
    Tamm, Eric P.
    Godoy, Myrna C.
    Sun, Jia
    Cody, Dianna D.
    RADIOLOGY, 2018, 287 (01) : 224 - 234
  • [5] Determining the invasiveness of pure ground-glass nodules using dual-energy spectral computed tomography
    Yu, Ye
    Cheng, Jie-Jun
    Li, Jian-Ying
    Zhang, Ying
    Lin, Liao-Yi
    Zhang, Feng
    Xu, Jian-Rong
    Zhao, Xiao-Jing
    Wu, Hua-Wei
    TRANSLATIONAL LUNG CANCER RESEARCH, 2020, 9 (03) : 484 - 495
  • [6] Detection of Lumbar Spine Osseous Metastases Using Dual-Energy CT: Phantom Results and Preliminary Clinical Validation
    Huang, Hsu-Cheng
    Srinivasan, Ramya
    Sun, Yuxin
    Kazakia, Galateia J.
    Lin, Pei-Chen
    Yeh, Benjamin M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (02) : 402 - 410
  • [7] Contrast-enhancement, image noise and dual-energy simulations for quantum-counting clinical CT
    Kappler, S.
    Niederloehner, D.
    Stierstorfer, K.
    Flohr, T.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [8] Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses
    Chandarana, Hersh
    Megibow, Alec J.
    Cohen, Benjamin A.
    Srinivasan, Ramya
    Kim, Danny
    Leidecker, Christianne
    Macari, Michael
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : W693 - W700
  • [9] Dual-energy contrast-enhanced CT to evaluate scaphoid osteonecrosis with surgical correlation
    Pianta, Marcus
    McCombe, David
    Slavin, John
    Hendry, Shona
    Perera, Warren
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2019, 63 (01) : 69 - 75
  • [10] Quantitative accuracy and dose efficiency of dual-contrast imaging using dual-energy CT: a phantom study
    Ren, Liqiang
    Rajendran, Kishore
    McCollough, Cynthia H.
    Yu, Lifeng
    MEDICAL PHYSICS, 2020, 47 (02) : 441 - 456