The utilization of automated external defibrillators in Taiwan

被引:9
|
作者
Wang, Tsung-Hsi [1 ,2 ]
Wu, Hsi-Wen [1 ]
Hou, Peter C. [3 ,4 ]
Tseng, Hao-Jui [5 ]
机构
[1] Minist Hlth & Welf, Taipei, Taiwan
[2] Natl Yang Ming Univ, Sch Med, Taipei, Taiwan
[3] Harvard Med Sch, Boston, MA USA
[4] Brigham & Womens Hosp, 75 Francis St, Boston, MA 02115 USA
[5] Buddhist Tzu Chi Med Fdn, Dalin Tzu Chi Hosp, Taipei, Taiwan
关键词
AED; Location; ROSC; Usage rate; HOSPITAL CARDIAC-ARREST;
D O I
10.1016/j.jfma.2018.02.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Increasing attention to care of patient succumbed to out-of-hospital cardiac arrest (OHCA) and evidence for improved survival have resulted in many countries to encourage the use automated external defibrillators (AEDs) by legislation. In Taiwan, the amendment of the Emergency Medical Services Act mandated the installation of AEDs in designated areas in 2013. Since then, 6151 AEDs have been installed and registered in mandated and non-mandated locations. The purpose of this study was to investigate the utilization of AEDs at mandated and non-mandated locations. Methods: This paper analyzed 217 cases in whom AEDs was used between July 11, 2013 and July 31, 2015. Descriptive statistics were used to analyze the data. Results: The highest frequency of AEDs used was in long-term care facilities, accounting for 34 (15.7%) cases. The second and third highest was in schools and commuting stations. The highest utilization rate of registered AED was in long-term care facilities (73.9%), the second was in residential areas, and the third was in hot spring areas. Employees at the designated locations or medical personnel operated the AED in 143 cases (84.6%), and bystanders, relatives, friends or others operated the AEDs in 26 cases (15.4%). On-site Return of Spontaneous Circulation (ROSC) after applying AEDs occurred in 76 cases (45.8%). Conclusion: Long-term care facilities had the highest utilization of AEDs and government should pay more attention to enforce the installing of AEDs in these places. The government also needs to promote the education public on how to search the AEDs locations. Copyright (C) 2018, Formosan Medical Association. Published by Elsevier Taiwan LLC.
引用
收藏
页码:148 / 151
页数:4
相关论文
共 50 条
  • [21] Home use of automated external defibrillators
    不详
    AMERICAN JOURNAL OF NURSING, 2008, 108 (10) : 72B - 72B
  • [22] Public use of automated external defibrillators
    Groeneveld, PW
    NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (08): : 755 - 756
  • [23] Importance of Automated external Defibrillators at Home
    Trappe, H. -J.
    KARDIOLOGE, 2008, 2 (03): : 210 - 213
  • [24] How useful are automated external defibrillators?
    Lovinger, SP
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 288 (23): : 2952 - 2952
  • [25] Automated external defibrillators - Selection and use
    Rubin, A
    PHYSICIAN AND SPORTSMEDICINE, 2000, 28 (03): : 112 - 114
  • [26] Charging up the public for automated external defibrillators
    DeJesus, PW
    CRITICAL CARE, 2005, 9 (02): : 147 - 148
  • [27] Are there disparities in the location of automated external defibrillators in England?
    Brown, Terry P.
    Perkins, Gavin D.
    Smith, Christopher M.
    Deakin, Charles D.
    Fothergill, Rachael
    RESUSCITATION, 2022, 170 : 28 - 35
  • [28] The shocking truth about automated external defibrillators
    Brown, J
    Kellermann, AL
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 284 (11): : 1438 - 1441
  • [29] PERFORMANCE OF AUTOMATED EXTERNAL DEFIBRILLATORS IN RURAL COMMUNITIES
    STULTS, K
    BROWN, D
    KERBER, R
    CIRCULATION, 1985, 72 (04) : 9 - 9
  • [30] Automated External Defibrillators and the Law of Unintended Consequences
    Haines, David E.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2010, 304 (19): : 2178 - 2179