Long-term Field Evaluation of Low-cost Particulate Matter Sensors in Nanjing

被引:39
|
作者
Bai, Lu [1 ]
Huang, Lin [1 ]
Wang, Zhenglu [2 ]
Ying, Qi [1 ,2 ]
Zheng, Jun [1 ]
Shi, Xiaowen [1 ]
Hu, Jianlin [1 ]
机构
[1] Nanjing Univ Informat Sci & Technol, Jiangsu Key Lab Atmospher Environm Monitoring & P, Jiangsu Collaborat Innovat Ctr Atmospher Environm, Nanjing 210044, Peoples R China
[2] Texas A&M Univ, Zachry Dept Civil Engn, College Stn, TX 77843 USA
基金
中国国家自然科学基金;
关键词
PPD42NS; Field calibration; Long-term; Artificial neural network; NEURAL-NETWORK MODEL; YANGTZE-RIVER DELTA; AIR-POLLUTION; PREMATURE MORTALITY; PM2.5; CHINA; PM10; EXPOSURE; CITIES; RISK;
D O I
10.4209/aaqr.2018.11.0424
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Low-cost particulate matter (PM) sensors can be widely deployed to measure aerosol concentrations at higher spatial and temporal resolutions than traditional instruments, but they need to be carefully calibrated under ambient conditions. In this study, a long-term field experiment was conducted from December 2015 to May 2017 at a site in Nanjing to evaluate the capabilities of in-house built low-cost PM monitors using the Shinyei PPD42NS sensor for ambient PM2.5 monitoring. A BAM-1020 particulate monitor was co-located with the low-cost sensors to provide reference readings. Least-square regressions with linear and power-law functions, and an artificial neural network (ANN) technique were used to convert electrical instrument readings to ambient aerosol concentrations. Applying the ANN technique resulted in the best estimation of the hourly PM2.5 (R-2 = 0.84; mean normalized bias = 12.7% and mean normalized error (MNE) = 29.7%). The low-cost sensors displayed relatively good performance with high aerosol concentrations but larger errors with concentrations below 35 mu g m(-3). High humidity (RH > 75%) can cause a larger MNE for these sensors, but the impact of temperature was negligible in this study. A clear sensor deterioration trend was observed during the 18-month field calibration. High correlations were found between the data from a single low-cost sensor and the data from the BAM-1020 when the low-cost sensor was individually calibrated, but the correlations between measurements taken by different low-cost sensor units were only moderate, possibly due to internal sensor variations. The results suggest that these low-cost sensors can measure ambient PM2.5 concentrations with an acceptable level of accuracy, which can and should be improved by calibrating each sensor individually. Special attention should be paid to the accuracy of these sensors after long-term application and in highly humid environments.
引用
收藏
页码:242 / 253
页数:12
相关论文
共 50 条
  • [31] Low-Cost Particulate Matter Sensors for Monitoring Residential Wood Burning
    Hassani, Amirhossein
    Schneider, Philipp
    Vogt, Matthias
    Castell, Nuria
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2023, 57 (40) : 15162 - 15172
  • [32] Ambient and laboratory evaluation of a low-cost particulate matter sensor
    Kelly, K. E.
    Whitaker, J.
    Petty, A.
    Widmer, C.
    Dybwad, A.
    Sleeth, D.
    Martin, R.
    Butterfield, A.
    ENVIRONMENTAL POLLUTION, 2017, 221 : 491 - 500
  • [33] Long-Term Performance Assessment of Low-Cost Atmospheric Sensors in the Arctic Environment
    Carotenuto, Federico
    Brilli, Lorenzo
    Gioli, Beniamino
    Gualtieri, Giovanni
    Vagnoli, Carolina
    Mazzola, Mauro
    Viola, Angelo Pietro
    Vitale, Vito
    Severi, Mirko
    Traversi, Rita
    Zaldei, Alessandro
    SENSORS, 2020, 20 (07)
  • [34] Validation of In-field Calibration for Low-Cost Sensors Measuring Ambient Particulate Matter in Kolkata, India
    Nobell, Siddharth
    Majumdar, Arnab
    Mukherjee, Shovon
    Chakraborty, Sukumar
    Chatterjee, Sanjoy
    Bose, Soumitra
    Dutta, Anindita
    Sethuraman, Sandhya
    Westervelt, Daniel M.
    Sengupta, Shairik
    Basu, Rakhi
    McNeill, V. Faye
    AEROSOL AND AIR QUALITY RESEARCH, 2023, 23 (11)
  • [35] Selection and Aggregation of Low-cost Particle Sensors for Outdoor Particulate Matter Measurement
    Li, Jie
    Xu, Zhengjia
    Nasar, Zaheer
    Ferracci, Valerio
    Harris, Neil
    2024 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2024, 2024,
  • [36] Accurate Lightweight Calibration Methods for Mobile Low-Cost Particulate Matter Sensors
    Jorstad, Per-Martin
    Wojcikowski, Marek
    Tuan-Vu Cao
    Lepioufle, Jean-Marie
    Wojtkiewicz, Krystian
    Phuong Hoai Ha
    INTELLIGENT INFORMATION AND DATABASE SYSTEMS, ACIIDS 2023, PT I, 2023, 13995 : 248 - 260
  • [37] A Low-Cost Sensors Study Measuring Exposure to Particulate Matter in Mobility Situations
    Aix, Marie-Laure
    Claitte, Melaine
    Bicout, Dominique J.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SENSOR NETWORKS, SENSORNETS 2023, 2023, : 32 - 41
  • [38] Regression methods in the calibration of low-cost sensors for ambient particulate matter measurements
    Marek Badura
    Piotr Batog
    Anetta Drzeniecka-Osiadacz
    Piotr Modzel
    SN Applied Sciences, 2019, 1
  • [39] Regression methods in the calibration of low-cost sensors for ambient particulate matter measurements
    Badura, Marek
    Batog, Piotr
    Drzeniecka-Osiadacz, Anetta
    Modzel, Piotr
    SN APPLIED SCIENCES, 2019, 1 (06):
  • [40] Calibration Methods for Low-Cost Particulate Matter Sensors Considering Seasonal Variability
    Kang, Jiwoo
    Choi, Kanghyeok
    SENSORS, 2024, 24 (10)