Long-term Field Evaluation of Low-cost Particulate Matter Sensors in Nanjing

被引:39
|
作者
Bai, Lu [1 ]
Huang, Lin [1 ]
Wang, Zhenglu [2 ]
Ying, Qi [1 ,2 ]
Zheng, Jun [1 ]
Shi, Xiaowen [1 ]
Hu, Jianlin [1 ]
机构
[1] Nanjing Univ Informat Sci & Technol, Jiangsu Key Lab Atmospher Environm Monitoring & P, Jiangsu Collaborat Innovat Ctr Atmospher Environm, Nanjing 210044, Peoples R China
[2] Texas A&M Univ, Zachry Dept Civil Engn, College Stn, TX 77843 USA
基金
中国国家自然科学基金;
关键词
PPD42NS; Field calibration; Long-term; Artificial neural network; NEURAL-NETWORK MODEL; YANGTZE-RIVER DELTA; AIR-POLLUTION; PREMATURE MORTALITY; PM2.5; CHINA; PM10; EXPOSURE; CITIES; RISK;
D O I
10.4209/aaqr.2018.11.0424
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Low-cost particulate matter (PM) sensors can be widely deployed to measure aerosol concentrations at higher spatial and temporal resolutions than traditional instruments, but they need to be carefully calibrated under ambient conditions. In this study, a long-term field experiment was conducted from December 2015 to May 2017 at a site in Nanjing to evaluate the capabilities of in-house built low-cost PM monitors using the Shinyei PPD42NS sensor for ambient PM2.5 monitoring. A BAM-1020 particulate monitor was co-located with the low-cost sensors to provide reference readings. Least-square regressions with linear and power-law functions, and an artificial neural network (ANN) technique were used to convert electrical instrument readings to ambient aerosol concentrations. Applying the ANN technique resulted in the best estimation of the hourly PM2.5 (R-2 = 0.84; mean normalized bias = 12.7% and mean normalized error (MNE) = 29.7%). The low-cost sensors displayed relatively good performance with high aerosol concentrations but larger errors with concentrations below 35 mu g m(-3). High humidity (RH > 75%) can cause a larger MNE for these sensors, but the impact of temperature was negligible in this study. A clear sensor deterioration trend was observed during the 18-month field calibration. High correlations were found between the data from a single low-cost sensor and the data from the BAM-1020 when the low-cost sensor was individually calibrated, but the correlations between measurements taken by different low-cost sensor units were only moderate, possibly due to internal sensor variations. The results suggest that these low-cost sensors can measure ambient PM2.5 concentrations with an acceptable level of accuracy, which can and should be improved by calibrating each sensor individually. Special attention should be paid to the accuracy of these sensors after long-term application and in highly humid environments.
引用
收藏
页码:242 / 253
页数:12
相关论文
共 50 条
  • [21] Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution
    Rueda, Emilio Molina
    Carter, Ellison
    L'Orange, Christian
    Quinn, Casey
    Volckens, John
    ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2023, 10 (03) : 247 - 253
  • [22] Low-cost sensors for measuring airborne particulate matter: Field evaluation and calibration at a South-Eastern European site
    Kosmopoulos, G.
    Salamalikis, V.
    Pandis, S. N.
    Yannopoulos, P.
    Bloutsos, A. A.
    Kazantzidis, A.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 748
  • [23] Calibration of low-cost particulate matter sensors for coal dust monitoring
    Amoah, Nana A.
    Xu, Guang
    Kumar, Ashish Ranjan
    Wang, Yang
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 859
  • [24] Investigation of Low-Cost and Optical Particulate Matter Sensors for Ambient Monitoring
    Rogulski, Mariusz
    Badyda, Artur
    ATMOSPHERE, 2020, 11 (10)
  • [25] A Review of Low-Cost Particulate Matter Sensors from the Developers' Perspectives
    Alfano, Brigida
    Barretta, Luigi
    Del Giudice, Antonio
    De Vito, Saverio
    Di Francia, Girolamo
    Esposito, Elena
    Formisano, Fabrizio
    Massera, Ettore
    Miglietta, Maria Lucia
    Polichetti, Tiziana
    SENSORS, 2020, 20 (23) : 1 - 56
  • [26] Evaluation and calibration of low-cost particulate matter sensors for respirable coal mine dust monitoring
    Feng, Zikang
    Zheng, Lina
    Zhang, Xuehan
    Liu, Jia
    Xue, Ning
    Wang, Mengmeng
    AEROSOL SCIENCE AND TECHNOLOGY, 2024, 58 (02) : 158 - 169
  • [27] Suitability of Low-Cost Particulate Matter Sensors for Measurements in Ventilation Systems
    Marval, Jesus
    Medina, Luis
    Vallejo, Juan
    Tronville, Paolo
    IAQ 2020: INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES, PT 2, 2022,
  • [28] Opportunities for Low-Cost Particulate Matter Sensors in Filter Emission Measurements
    Schwarz, Almuth D.
    Meyer, Joerg
    Dittler, Achim
    CHEMICAL ENGINEERING & TECHNOLOGY, 2018, 41 (09) : 1826 - 1832
  • [29] A Review of Literature on the Usage of Low-Cost Sensors to Measure Particulate Matter
    Raysoni, Amit U.
    Pinakana, Sai Deepak
    Mendez, Esmeralda
    Wladyka, Dawid
    Sepielak, Katarzyna
    Temby, Owen
    EARTH, 2023, 4 (01): : 168 - 186
  • [30] Laboratory evaluation of particle-size selectivity of optical low-cost particulate matter sensors
    Kuula, Joel
    Makela, Timo
    Aurela, Minna
    Teinila, Kimmo
    Varjonen, Samu
    Gonzalez, Oscar
    Timonen, Hilkka
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2020, 13 (05) : 2413 - 2423