High-Resolution Ultrasound Perfusion Imaging of Therapeutic Angiogenesis

被引:47
|
作者
Rissanen, Tuomas T.
Korpisalo, Petra
Karvinen, Henna
Liimatainen, Timo [2 ,3 ]
Laidinen, Svetlana
Grohn, Olli H. [2 ,3 ]
Yla-Herttuala, Seppo [1 ,4 ,5 ]
机构
[1] Univ Kuopio, AI Virtanen Inst, Dept Biotechnol & Mol Med, FIN-70211 Kuopio, Finland
[2] AI Virtanen Inst, Dept Biomed Nucl Magnet Resonance, Kuopio, Finland
[3] AI Virtanen Inst, Natl Bio Nucl Magnet Resonance Facil, Kuopio, Finland
[4] Kuopio Univ Hosp, Dept Med, SF-70210 Kuopio, Finland
[5] Kuopio Univ Hosp, Gene Therapy Unit, SF-70210 Kuopio, Finland
基金
芬兰科学院;
关键词
D O I
10.1016/j.jcmg.2007.10.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of this study was to test the feasibility of contrast pulse sequence (CPS) ultrasound imaging for high-resolution perfusion imaging after gene transfer (GT) for therapeutic angiogenesis. BACKGROUND Imaging modalities capable of accurate and feasible perfusion measurement are essential for the preclinical and clinical development of therapeutic angiogenesis. However, current methods suffer from compromises between spatial and temporal resolution and sensitivity. Contrast pulse sequence ultrasound is a recently developed real-time perfusion imaging method that generates high-contrast agent-to-tissue specificity and spatial resolution. METHODS Contrast pulse sequence ultrasound was used to noninvasively assess parameters of blood flow 6 days after adenoviral vascular endothelial growth factor (AdVEGF) GT in rabbit and mouse hind limbs with bolus intravenous injection of a microbubble contrast medium. Blood volume, mean transit time, perfusion, and time to the arrival of the contrast bolus were calculated with the gamma variate function. Contrast-enhanced power Doppler ultrasound (CEU), dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI), and histological capillary measurements were used as reference methods. RESULTS Blood volume and perfusion increased over 40- and 20-fold, respectively, 6 days after AdVEGF GT in rabbit skeletal muscles. Perfusion values measured with CPS correlated well with those obtained with CEU (r = 0.975) and DCE-MRI (r = 0.854). However, CPS provided superior spatial and temporal resolution showing blood flow in vessels of only 10 to 20 mu m in diameter. Contrast pulse sequence ultrasound was also feasible for imaging of therapeutic angiogenesis in mouse hind limbs both at the arterial and capillary levels. The CPS ultrasound revealed that AdVEGF mainly induces angiogenesis in adipose tissue rather than in the skeletal muscle of mouse hind limbs. CONCLUSIONS Contrast pulse sequence ultrasound is an efficient and accurate noninvasive real-time perfusion imaging modality in small laboratory animals and also offers a means for the assessment of muscle perfusion in future clinical trials of therapeutic angiogenesis. (J Am Coll Cardiol Img 2008;1:83-91) (C) 2008 by the American College of Cardiology Foundation
引用
收藏
页码:83 / 91
页数:9
相关论文
共 50 条
  • [1] High resolution ultrasound perfusion imaging of therapeutic angiogenesis
    Rissanen, Tuomas
    Koripisalo, Petra
    Karvinen, Henna
    Liimatainen, Timo
    Laidinen, Svetlana.
    Grohn, Olli
    Yla-Herttuala, Seppo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 119 : S8 - S8
  • [2] High-resolution ultrasound imaging of the mouse
    Renault, G.
    Bonnin, P.
    Marchiol-Fournigault, C.
    Gregoire, J. M.
    Serriere, S.
    Richard, B.
    Fradelizi, D.
    JOURNAL DE RADIOLOGIE, 2006, 87 (12): : 1937 - 1945
  • [3] LONGITUDINAL MONITORING OF ANGIOGENESIS USING HIGH-RESOLUTION THREE-DIMENSIONAL ULTRASOUND IMAGING
    Mukai, K.
    Zhu, W.
    Nakajima, Y.
    Kobayashi, M.
    Nakatani, T.
    WOUND REPAIR AND REGENERATION, 2018, 26 (02) : A5 - A5
  • [4] Experimental ultrasound imaging of cerebral perfusion at high resolution
    Butler, WE
    NEUROSURGERY, 2004, 55 (02) : 462 - 462
  • [5] High-resolution ultrasound imaging of the eye - a review
    Silverman, Ronald H.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 37 (01): : 54 - 67
  • [6] HIGH-RESOLUTION HARMONICS ULTRASOUND AND LASER SPECKLE IMAGING FOR NONINVASIVE CHARACTERIZATION OF WOUND PERFUSION AND HEALING
    Gnyawali, S.
    Ganesh, K.
    Mathew, S.
    Dixith, S.
    Vanzant, D.
    Roy, S.
    Datta, S.
    Sen, C. K.
    WOUND REPAIR AND REGENERATION, 2015, 23 (02) : A23 - A23
  • [7] DIFFUSION AND PERFUSION IN HIGH-RESOLUTION NMR IMAGING AND MICROSCOPY
    AHN, CB
    CHO, ZH
    MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) : 228 - 232
  • [8] Virtual ultrasound sources in high-resolution ultrasound imaging.
    Nikolov, SI
    Jensen, JA
    MEDICAL IMAGE 2002: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2002, 4687 : 395 - 405
  • [9] Novel instrument for high-resolution ultrasound flow imaging
    Tortoli, P
    Guidi, F
    Guidi, G
    Berti, P
    Atzeni, C
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1997, 8 (05) : 438 - 443
  • [10] High-resolution ultrasound imaging of elementary lesions in dactylitis
    Ricci, Vincenzo
    Tamborrini, Giorgio
    Zunica, Fiammetta
    Chang, Ke-Vin
    Kara, Murat
    Fari, Giacomo
    Nanka, Ondrej
    Ozcakar, Levent
    JOURNAL OF ULTRASOUND, 2024, 27 (02) : 281 - 290