Global left-ventricular function assessment using dual-source multidetector CT: effect of improved temporal resolution on ventricular volume measurement

被引:29
作者
Puesken, Michael [1 ]
Fischbach, Roman [1 ,2 ]
Wenker, Mirja [1 ]
Seifarth, Harald [1 ]
Maintz, David [1 ]
Heindel, Walter [1 ]
Juergens, Kai Uwe [1 ]
机构
[1] Univ Munster, Dept Clin Radiol, D-48149 Munster, Germany
[2] Asklepios Klin Altona, Dept Radiol, D-22763 Hamburg, Germany
关键词
dual-source computed tomography (DSCT); temporal resolution; left-ventricular volumes; global left-ventricular function; 3D threshold-based segmentation;
D O I
10.1007/s00330-008-0982-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose was to compare global left-ventricular (LV) function parameters measured with cine MRI with results from multiphase dual-source CT (DSCT) using 10 and 20 reconstruction phases. Twenty-eight patients with suspected or known CAD underwent DSCT coronary angiography. LV end-diastolic (EDV), end-systolic (ESV) and stroke volumes (SV), and ejection fraction (EF) were determined using LV segmentation and selection of specific phases from DSCT image sets reconstructed either at 5% or 10% steps through the R-R interval. Cine MRI served as the reference investigation. Threshold-based 3D-segmentation was feasible in all DSCT data sets. EDV and ESV were underestimated by DSCT, but showed excellent correlation (Pearson's correlation coefficient 0.95/0.97) to values obtained with MRI. Using data from 5% DSCT image reconstructions instead of 10% phase reconstructions, the position of the ED and ES phase was changed in 16 of 28 patients; ESVs were to found to be slightly smaller, whereas EDV were slightly larger, resulting in a systematic overestimation of LV EF by 1.9% (p = 0.56). Threshold-based 3D segmentation enables accurate and reliable DSCT determination of global LV function with excellent correlation to cine MRI. Minor differences in LV EF indicate that both modalities are virtually interchangeable, even if the number of reconstructed phases is limited to 10% phase reconstructions.
引用
收藏
页码:2087 / 2094
页数:8
相关论文
共 35 条
[1]   Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences [J].
Alfakih, K ;
Plein, S ;
Thiele, H ;
Jones, T ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :323-329
[2]   Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography - Comparison with cine magnetic resonance imaging [J].
Belge, Benedicte ;
Coche, Emmanuel ;
Pasquet, Agnes ;
Vanoverschelde, Jean-Louis J. ;
Gerber, Bernhard L. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1424-1433
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Dual-source CT with improved temporal resolution in assessment of left ventricular function: A pilot study [J].
Brodoefel, Harald ;
Kramer, Ulrich ;
Reimann, Anja ;
Burgstahler, Christof ;
Schroeder, Stephen ;
Kopp, Andreas ;
Heuschmid, Martin .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (05) :1064-1070
[5]  
BUSCH S, 2007, EUR RADIOL
[6]   Evaluation of a semiautomatic software tool for left ventricular function analysis with 16-slice computed tomography [J].
Dewey, M ;
Müller, M ;
Teige, F ;
Hamm, B .
EUROPEAN RADIOLOGY, 2006, 16 (01) :25-31
[7]   Evaluation of global and regional left ventricular function with 16-slice computed tomography, biplane cineventriculography, and two-dimensional transthoracic echocardiography -: Comparison with magnetic resonance imaging [J].
Dewey, Marc ;
Mueller, Mira ;
Eddicks, Stephan ;
Schnapauff, Dirk ;
Teige, Florian ;
Rutsch, Wolfgang ;
Borges, Adrian C. ;
Hamm, Bernd .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) :2034-2044
[8]   Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography [J].
Dirksen, MS ;
Bax, JJ ;
de Roos, A ;
Jukema, JW ;
van der Geest, RJ ;
Geleijns, K ;
Boersma, E ;
van der Wall, EE ;
Lamb, HJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (10) :1157-+
[9]   Assessment of regional left ventricular function with multidetector-row computed tomography versus magnetic resonance imaging [J].
Fischbach, Roman ;
Juergens, Kai Uwe ;
Ozgun, Murat ;
Maintz, David ;
Grude, Matthias ;
Seifarth, Harald ;
Heindel, Walter ;
Wichter, Thomas .
EUROPEAN RADIOLOGY, 2007, 17 (04) :1009-1017
[10]   Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography - Comparison with magnetic resonance imaging [J].
Grude, M ;
Juergens, KU ;
Wichter, T ;
Paul, M ;
Fallenberg, EM ;
Muller, JG ;
Heindel, W ;
Breithardt, G ;
Fischbach, R .
INVESTIGATIVE RADIOLOGY, 2003, 38 (10) :653-661