Reproduction of Hip Offset and Leg Length in Navigated Total Hip Arthroplasty: How Accurate Are We?

被引:20
作者
Ellapparadja, Pregash [1 ]
Mahajan, Vivek [1 ]
Deakin, Angela H. [1 ]
Deep, Kamal [1 ]
机构
[1] Golden Jubilee Natl Hosp, Clydebank G81 4DY, Scotland
关键词
navigation; hip offset; THR; Orthopilot; leg length; DISCREPANCY;
D O I
10.1016/j.arth.2015.01.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study assesses how accurately we can restore hip offset and leg length in navigated total hip arthroplasty (THA). 152 consecutive patients with navigated THA formed the study group. The contra-lateral hip formed control for measuring hip offset and leg length. All radiological measurements were made using Orthoview digital software. In the normal hip offset group, the mean is 75.73 (SD-8.61). In the reconstructed hip offset group, the mean is 75.35 (SD -7.48). 95.39% had hip offset within 6 mm of opposite side while 96.04% had leg length restored within 6 mm of contra-lateral side. Equivalence test revealed that the two groups of hip offsets were essentially the same. We conclude that computer navigation can successfully reproduce hip offset and leg length accurately. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1002 / 1007
页数:6
相关论文
共 24 条
[1]   Do we medialise the hip centre of rotation in total hip arthroplasty? Influence of acetabular offset and surgical technique [J].
Bonnin, Michel P. ;
Archbold, Pooler H. A. ;
Basiglini, Lucas ;
Fessy, Michel H. ;
Beverland, David E. .
HIP INTERNATIONAL, 2012, 22 (04) :371-378
[2]   Hip Offset in Total Hip Arthroplasty Quantitative Measurement with Navigation [J].
Dastane, Manish ;
Dorr, Lawrence D. ;
Tarwala, Rupesh ;
Wan, Zhinian .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :429-436
[3]  
Goodman SB, 1988, CLIN ORTHOP RELAT R, V236, P1999
[4]   Anterior Pelvic Soft Tissue Thickness Influences Acetabular Cup Positioning with Imageless Navigation [J].
Hohmann, Erik ;
Bryant, Adam ;
Tetsworth, Kevin .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :945-952
[5]   Effect of Training Level on Accuracy of Digital Templating in Primary Total Hip and Knee Arthroplasty [J].
Hsu, Andrew R. ;
Kim, Jeffrey D. ;
Bhatia, Sanjeev ;
Levine, Brett R. .
ORTHOPEDICS, 2012, 35 (02) :E179-E183
[6]   Anteroposterior pelvic radiographs to assess acetabular retroversion: High validity of the "cross-over-sign" [J].
Jamali, Amir A. ;
Mladenov, Kiril ;
Meyer, Dominik C. ;
Martinez, Alberto ;
Beck, Martin ;
Ganz, Reinhold ;
Leunig, Michael .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2007, 25 (06) :758-765
[7]   OrthoPilot cup navigation - how to optimise cup positioning? [J].
Kiefer, H .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 :S37-S42
[8]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[9]   Femoral offset: Anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty [J].
Lecerf, G. ;
Fessy, M. H. ;
Philippot, R. ;
Massin, P. ;
Giraud, F. ;
Flecher, X. ;
Girard, J. ;
Mertl, P. ;
Marchetti, E. ;
Stindel, E. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (03) :210-219
[10]   Error in acetabular socket alignment due to the thick anterior pelvic soft tissues [J].
Lee, Yeon Soo ;
Yoon, Taek Rim .
JOURNAL OF ARTHROPLASTY, 2008, 23 (05) :699-706