Bystander automated external defibrillator application in non-shockable out-of-hospital cardiac arrest

被引:8
作者
Pollack, Ross A. [1 ]
Brown, Siobhan P. [2 ]
May, Susanne [2 ]
Rea, Tom [3 ]
Kudenchuk, Peter J. [4 ]
Weisfeldt, Myron L. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, 1812 Ashland Ave Suite 110, Baltimore, MD 21205 USA
[2] Univ Washington, Sch Publ Hlth, 6200 NE 74th St,Bldg 29,Suite 250, Seattle, WA 98115 USA
[3] Univ Washington, Sch Med, 325 Ninth Ave, Seattle, WA 98104 USA
[4] Univ Washington, Sch Med, 1959 NE Pacific St,3rd Floor, Seattle, WA 98195 USA
基金
加拿大健康研究院;
关键词
Automated external defibrillator; Cardiopulmonary resuscitation; Out-of-hospital cardiac arrest; Sudden cardiac arrest; PUBLIC-ACCESS DEFIBRILLATION; SURVIVAL; OUTCOMES; DRONE; TIME;
D O I
10.1016/j.resuscitation.2019.02.007
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: An increasing proportion of patients with OHCA present with non-shockable rhythms, among whom the benefit from AED application is not known. Methods: We performed a retrospective analysis of adults with non-traumatic, public, bystander-witnessed, non-shockable OHCA occurring between 2005-2015 at 9 locations participating in the Resuscitation Outcomes Consortium. Non-shockable arrest was defined as when no shock was administered by a bystander applied AED and confirmed by the initial rhythm on EMS arrival. Outcomes were compared between patients with non-shockable OHCA in whom a bystander AED was or was not applied. Results: Among 2809 patients with non-shockable public, witnessed OHCA, 8.4% had an AED applied. CPR was more often performed in the AED-applied group (99% vs. 51% of patients, p 0.001). Among patients in whom an AED was not applied, 39.8% had any pre-hospital ROSC, 29.6% had a pulse at ED arrival and 11.1% survived to hospital discharge compared to 44.1%, 29.6% and 9.7%, respectively with AED application. After adjustment for the Utstein variables excluding bystander CPR, the OR for survival to hospital discharge for AED application was 0.90 (95% CI:0.57-1.42); when adjusted for the higher frequency of CPR in the AED group the OR was 0.92 (95% CI:0.57-1.47). Conclusions: The application of an AED in non-shockable public witnessed OHCA was associated with a higher frequency of bystander CPR. The probabilities of pre-hospital ROSC, pulse at ED arrival, and survival to hospital discharge were not altered by the application of an AED.
引用
收藏
页码:168 / 174
页数:7
相关论文
共 26 条
  • [21] LOCATING AED ENABLED MEDICAL DRONES TO ENHANCE CARDIAC ARREST RESPONSE TIMES
    Pulver, Aaron
    Wei, Ran
    Mann, Clay
    [J]. PREHOSPITAL EMERGENCY CARE, 2016, 20 (03) : 378 - 389
  • [22] RANKIN J, 1957, Scott Med J, V2, P200
  • [23] Minimizing pre- and post-defibrillation pauses increases the likelihood of return of spontaneous circulation (ROSC)
    Sell, Rebecca E.
    Sarno, Renee
    Lawrence, Brenna
    Castillo, Edward M.
    Fisher, Roger
    Brainard, Criss
    Dunford, James V.
    Davis, Daniel P.
    [J]. RESUSCITATION, 2010, 81 (07) : 822 - 825
  • [24] Outcomes of rapid defibrillation by security officers after cardiac arrest in casinos.
    Valenzuela, TD
    Roe, DJ
    Nichol, G
    Clark, LL
    Spaite, DW
    Hardman, RG
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (17) : 1206 - 1209
  • [25] Ventricular Tachyarrhythmias after Cardiac Arrest in Public versus at Home
    Weisfeldt, Myron L.
    Everson-Stewart, Siobhan
    Sitlani, Colleen
    Rea, Thomas
    Aufderheide, Tom P.
    Atkins, Dianne L.
    Bigham, Blair
    Brooks, Steven C.
    Foerster, Christopher
    Gray, Randal
    Ornato, Joseph P.
    Powell, Judy
    Kudenchuk, Peter J.
    Morrison, Laurie J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (04) : 313 - 321
  • [26] The use of CPR feedback/prompt devices during training and CPR performance: A systematic review
    Yeung, Joyce
    Meeks, Reylon
    Edelson, Dana
    Gao, Fang
    Soar, Jasmeet
    Perkins, Gavin D.
    [J]. RESUSCITATION, 2009, 80 (07) : 743 - 751