Objective. Neural interfaces need to become more unobtrusive and socially acceptable to appeal to general consumers outside rehabilitation settings. Approach. We developed a non-invasive neural interface that provides access to spinal motor neuron activities from the wrist, which is the preferred location for a wearable. The interface decodes far-field potentials present at the tendon endings of the forearm muscles using blind source separation. First, we evaluated the reliability of the interface to detect motor neuron firings based on far-field potentials, and thereafter we used the decoded motor neuron activity for the prediction of finger contractions in offline and real-time conditions. Main results. The results showed that motor neuron activity decoded from the far-field potentials at the wrist accurately predicted individual and combined finger commands and therefore allowed for highly accurate real-time task classification. Significance. These findings demonstrate the feasibility of a non-invasive, neural interface at the wrist for precise real-time control based on the output of the spinal cord.
引用
收藏
页数:15
相关论文
共 58 条
[1]   Human Machine Interfaces in Upper-Limb Prosthesis Control: A Survey of Techniques for Preprocessing and Processing of Biosignals [J].
Ahmadizadeh, Chakaveh ;
Khoshnam, Mahta ;
Menon, Carlo .
IEEE SIGNAL PROCESSING MAGAZINE, 2021, 38 (04) :12-22
[2]   REGULATION OF THE FIRING PATTERN OF SINGLE MOTOR UNITS [J].
ANDREASSEN, S ;
ROSENFALCK, A .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1980, 43 (10) :897-906
[3]  
Ariyanto M, 2015, PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON AUTOMATION, COGNITIVE SCIENCE, OPTICS, MICRO ELECTRO-MECHANICAL SYSTEM, AND INFORMATION TECHNOLOGY (ICACOMIT), P12, DOI 10.1109/ICACOMIT.2015.7440146
[4]   Control of Spinal Motoneurons by Feedback From a Non-Invasive Real-Time Interface [J].
Barsakcioglu, Deren Y. ;
Bracklein, Mario ;
Holobar, Ales ;
Farina, Dario .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (03) :926-935
[5]   An exoskeleton controlled by an epidural wireless brain-machine interface in a tetraplegic patient: a proof-of-concept demonstration [J].
Benabid, Alim Louis ;
Costecalde, Thomas ;
Eliseyev, Andrey ;
Charvet, Guillaume ;
Verney, Alexandre ;
Karakas, Serpil ;
Foerster, Michael ;
Lambert, Aurelien ;
Moriniere, Boris ;
Abroug, Neil ;
Schaeffer, Marie-Caroline ;
Moly, Alexandre ;
Sauter-Starace, Fabien ;
Ratel, David ;
Moro, Cecile ;
Torres-Martinez, Napoleon ;
Langar, Lilia ;
Oddoux, Manuela ;
Polosan, Mircea ;
Pezzani, Stephane ;
Auboiroux, Vincent ;
Aksenova, Tetiana ;
Mestais, Corinne ;
Chabardes, Stephan .
LANCET NEUROLOGY, 2019, 18 (12) :1112-1122
[6]  
Botros F. S., 2020, IN PRESS, V18, P174, DOI [DOI 10.1109/TII.2020.3041618, 10.1109/TII.2020.3041618]
[7]   Current Trends and Confounding Factors in Myoelectric Control: Limb Position and Contraction Intensity [J].
Campbell, Evan ;
Phinyomark, Angkoon ;
Scheme, Erik .
SENSORS, 2020, 20 (06)
[8]   Adaptive Real-Time Identification of Motor Unit Discharges From Non-Stationary High-Density Surface Electromyographic Signals [J].
Chen, Chen ;
Ma, Shihan ;
Sheng, Xinjun ;
Farina, Dario ;
Zhu, Xiangyang .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (12) :3501-3509
[9]   Hand gesture recognition based on motor unit spike trains decoded from high-density electromyography [J].
Chen, Chen ;
Yu, Yang ;
Ma, Shihan ;
Sheng, Xinjun ;
Lin, Chuang ;
Farina, Dario ;
Zhu, Xiangyang .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 55
[10]   Prediction of finger kinematics from discharge timings of motor units: implications for intuitive control of myoelectric prostheses [J].
Chen, Chen ;
Chai, Guohong ;
Guo, WeiChao ;
Sheng, Xinjun ;
Farina, Dario ;
Zhu, Xiangyang .
JOURNAL OF NEURAL ENGINEERING, 2019, 16 (02)