Vector flow estimator isomorphism and wall filter requirements

被引:0
作者
Anderson, ME [1 ]
机构
[1] Univ Rochester, Dept Biomed Engn, Rochester, NY 14627 USA
来源
MEDICAL IMAGING 2001: ULTRASONIC IMAGING AND SIGNAL PROCESSING | 2001年 / 4325卷
关键词
ultrasound; Doppler; flow estimation; vector flow; spatial quadrature;
D O I
10.1117/12.428198
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Ultrasound vector flow estimation can be complicated by the spatial anisotropy of the ultrasound pulse, a limitation most commonly characterized in terms of the different spatial resolutions achieved along the three axes of a typical imaging system. For vector Doppler or spatial quadrature flow estimation techniques, this anisotropy limits, relative to the axial modulation, the maximum achievable frequency of the modulation associated with lateral motion. This anisotropy has one advantage in establishing higher aliasing thresholds in the non-axial dimensions than are typically encountered axially. However, it is likely that one of the obstacles to practical implementation of vector velocity estimation will be the attenuation of non-axial modulation components by conventional wall and clutter filters. As part of our investigation of this topic, we describe a commonality among several vector flow estimators: the vector Doppler described by Overbeck, et. al, the estimator described by Jensen and Munk, and the heterodyning spatial quadrature estimator we have previously described. When implemented with the same transducer array, these estimators produce very similar spatial impulse responses despite the use of radically different complex apodization schemes. In two cases this common response is not formed during beamforming but rather after post-processing has been applied, We describe this isomorphism and discuss the differences among the estimators that we expect to become evident under realistic imaging conditions. We present an analysis of the multi-dimensional spatial frequency responses of these vector velocity estimators in comparison with typical wall filter responses. The axial/lateral anisotropy for all three estimators was found to be on the order of 10 in a pulse-echo regime. This implies that detection of lateral flow at a rate of, for example, 10 m/s would require a wall filter setting providing an axial cut-off velocity of less than 1 m/s. The practical implications of these findings and alternative approaches are discussed.
引用
收藏
页码:215 / 226
页数:12
相关论文
共 16 条
[1]   Multi-dimensional velocity estimation with ultrasound using spatial quadrature [J].
Anderson, ME .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (03) :852-861
[2]  
ANDERSON ME, 2000, IN PRESS P IEEE ULTR
[3]  
Bjaerum S, 1997, 1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, P1223, DOI 10.1109/ULTSYM.1997.661799
[4]  
Bonnefous O., 1986, IEEE 1986 Ultrasonics Symposium Proceedings (Cat. No.86CH2375-4), P855
[5]   Blood speed imaging with an intraluminal array [J].
Crowe, JR ;
Shapo, BM ;
Stephens, DN ;
Bleam, D ;
Eberle, MJ ;
Céspedes, EI ;
Wu, CC ;
Muller, DWM ;
Kovach, JA ;
Lederman, RJ ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (03) :672-681
[6]   CALCULATION OF PRESSURE FIELDS FROM ARBITRARILY SHAPED, APODIZED, AND EXCITED ULTRASOUND TRANSDUCERS [J].
JENSEN, JA ;
SVENDSEN, NB .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (02) :262-267
[7]   A new method for estimation of velocity vectors [J].
Jensen, JA ;
Munk, P .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (03) :837-851
[8]  
Jensen JA, 1999, ULTRASON, P1465, DOI 10.1109/ULTSYM.1999.849273
[9]  
MEBREE PM, 1985, P IEEE ULTR S, P963
[10]   ULTRASOUND DOPPLER PROBING OF FLOWS TRANSVERSE WITH RESPECT TO BEAM AXIS [J].
NEWHOUSE, VL ;
CENSOR, D ;
VONTZ, T ;
CISNEROS, JA ;
GOLDBERG, BB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (10) :779-789