Computational modeling of a single-element transcranial focused ultrasound transducer for subthalamic nucleus stimulation

被引:25
作者
Samoudi, Mohammed A. [1 ]
Van Renterghem, Timothy [1 ]
Botteldooren, Dick [1 ]
机构
[1] Univ Ghent, WAVES Res Grp, Dept Informat Technol, Ghent, Belgium
关键词
ultrasonic neuromodulation; deep brain stimulation; full-wave numerical simulations; subthalamic nucleus stimulation; transcranial focused ultrasound; BRAIN-STIMULATION; SKULL; NEUROSTIMULATION; SIMULATIONS; PROPAGATION; THALAMOTOMY; THERAPY;
D O I
10.1088/1741-2552/aafa38
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. While transcranial focused ultrasound is a very promising neuromodulation technique for its non-invasiveness and high spatial resolution, its application to the human deep brain regions such as the subthalamic nucleus (STN) is relatively new. The objective of this study is to design a simple ultrasound transducer and study the transcranial wave propagation through a highly realistic human head model. The effects of skull morphology and skull and brain tissue properties on the focusing performance and energy deposition must therefore be known. Approach. A full-wave finite-difference time-domain simulation platform was used to design and simulate ultrasound radiation from a single-element focused transducer (SEFT) to the STN. Simulations were performed using the state-of-the-art Multimodal Imaging-based and highly Detailed Anatomical (MIDA) head model. In addition, the impact of changes in sound speed, density, and tissue attenuation coefficients were assessed through a sensitivity analysis. Main results. A SEFT model was designed to deliver an intensity of around 100 W m(-2) to the STN region; 20% of the STN volume was sonicated with at least half of the maximum of the peak intensity and it was predicted that 61.5% of the volume of the beam (above half of the peak intensity) falls inside the STN region. The sensitivity analysis showed that the skull's sound speed is the most influential acoustic parameter, which must be known with less than 1.2% error to obtain an acceptable accuracy in intracranial fields and focusing (for less than 5% error). Significance. Ultrasound intensity delivery at the STN by a simple single element transducer is possible and could be a promising alternative to complex multi-element phased arrays, or more general, to invasive or less focused (non-acoustic) neuromodulation techniques. Accurate acoustic skull and brain parameters, including detailed skull geometry, are needed to ensure proper targeting in the deep brain region.
引用
收藏
页数:12
相关论文
共 49 条
[1]   A review of low-intensity focused ultrasound for neuromodulation [J].
Baek H. ;
Pahk K.J. ;
Kim H. .
Kim, Hyungmin (hk@kist.re.kr), 2017, Springer Verlag (07) :135-142
[2]  
Bauer Ronald, 2014, Parkinsonism Relat Disord, V20 Suppl 1, pS197, DOI 10.1016/S1353-8020(13)70046-4
[3]   A review of low-intensity focused ultrasound pulsation [J].
Bystritsky, Alexander ;
Korb, Alex S. ;
Douglas, Pamela K. ;
Cohen, Mark S. ;
Melega, William P. ;
Mulgaonkar, Amit P. ;
DeSalles, Antonio ;
Min, Byoung-Kyong ;
Yoof, Seung-Schik .
BRAIN STIMULATION, 2011, 4 (03) :125-136
[4]   Modeling weakly nonlinear acoustic wave propagation [J].
Christov, Ivan ;
Christov, C. I. ;
Jordan, P. M. .
QUARTERLY JOURNAL OF MECHANICS AND APPLIED MATHEMATICS, 2007, 60 (473-495) :473-495
[5]   Correlation of ultrasound phase with physical skull properties [J].
Clement, GT ;
Hynynen, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (05) :617-624
[6]   Functional somatotopy of finger representations in human primary motor cortex [J].
Dechent, P ;
Frahm, J .
HUMAN BRAIN MAPPING, 2003, 18 (04) :272-283
[7]   Low-Intensity Focused Ultrasound Modulates Monkey Visuomotor Behavior [J].
Deffieux, Thomas ;
Younan, Youliana ;
Wattiez, Nicolas ;
Tanter, Mickael ;
Pouget, Pierre ;
Aubry, Jean-Francois .
CURRENT BIOLOGY, 2013, 23 (23) :2430-2433
[8]   Numerical Study of a Simple Transcranial Focused Ultrasound System Applied to Blood-Brain Barrier Opening [J].
Deffieux, Thomas ;
Konofagou, Elisa E. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (12) :2637-2653
[9]   A Pilot Study of Focused Ultrasound Thalamotomy for Essential Tremor [J].
Elias, W. Jeffrey ;
Huss, Diane ;
Voss, Tiffini ;
Loomba, Johanna ;
Khaled, Mohamad ;
Zadicario, Eyal ;
Frysinger, Robert C. ;
Sperling, Scott A. ;
Wylie, Scott ;
Monteith, Stephen J. ;
Druzgal, Jason ;
Shah, Binit B. ;
Harrison, Madaline ;
Wintermark, Max .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (07) :640-648
[10]  
Foote K, 2006, J ACOUST SOC AM, V119, P3232