Determination of platinum-group metals and lead in vegetable environmental bio-monitors by voltammetric and spectroscopic techniques: critical comparison

被引:154
作者
Locatelli, C
Melucci, D
Torsi, G
机构
[1] Univ Bologna, Dept Chem G Ciamician, I-40126 Bologna, Italy
[2] Univ Bologna, CIRSA, Analyt Environm Chem Lab, I-48100 Ravenna, Italy
关键词
platinum-group metals; lead; voltammetry; spectroscopy; vegetables;
D O I
10.1007/s00216-005-3356-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports voltammetric sequential determination of Pt(II), Pd(II), and Rh(III), by square-wave adsorption stripping voltammetry (SWAdSV), and Pb(II), by square-wave anodic stripping voltammetry (SWASV), in vegetable environmental matrices. Analytical procedures were verified by the analysis of the standard reference materials: Olive Leaves BCR-CRM 062 and Tomato Leaves NIST-SRM 1573a. Precision and accuracy, expressed as relative standard deviation and relative error, respectively, were always less than 6% and the limits of detection (LOD) for each element were below 0.096 mu g g(-1). Once set up on the standard reference materials, the analytical procedure was transferred and applied to laurel leaves sampled in proximity to a superhighway and in the Po river mouth area. A critical comparison with spectroscopic measurements is discussed.
引用
收藏
页码:1567 / 1573
页数:7
相关论文
共 32 条
[1]  
[Anonymous], 1978, SPECTROCHIM ACTA, DOI DOI 10.1016/0584-8547(78)80044-5
[2]   Distribution and speciation of platinum group elements in environmental matrices [J].
Barefoot, RR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (11) :702-707
[3]   Recent advances in the determination of the platinum group elements and gold [J].
Barefoot, RR ;
Van Loon, JC .
TALANTA, 1999, 49 (01) :1-14
[4]   Determination of palladium by adsorptive stripping voltammetry [J].
Georgieva, M ;
Pihlar, B .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (07) :874-880
[5]   Levels and risk assessment for humans and ecosystems of platinum-group elements in the airborne particles and road dust of some European cities [J].
Gómez, B ;
Palacios, MA ;
Gómez, M ;
Sanchez, JL ;
Morrison, G ;
Rauch, S ;
McLeod, C ;
Ma, R ;
Caroli, S ;
Alimonti, A ;
Petrucci, F ;
Bocca, B ;
Schramel, P ;
Zischka, M ;
Petterson, C ;
Wass, U .
SCIENCE OF THE TOTAL ENVIRONMENT, 2002, 299 (1-3) :1-19
[6]   Platinum and rhodium distribution in airborne particulate matter and road dust [J].
Gómez, B ;
Gómez, M ;
Sanchez, JL ;
Fernández, R ;
Palacios, MA .
SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 269 (1-3) :131-144
[7]   Control of interferences in the determination of Pt, Pd and Rh in airborne particulate matter by inductively coupled plasma mass spectrometry [J].
Gomez, MB ;
Gomez, MM ;
Palacios, MA .
ANALYTICA CHIMICA ACTA, 2000, 404 (02) :285-294
[8]   Comparison of traditional and multivariate calibration techniques applied to complex matrices using inductively coupled plasma atomic emission spectroscopy [J].
Grifrths, ML ;
Svozil, D ;
Worsfold, PJ ;
Denham, S ;
Evans, EH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (08) :967-972
[9]   Distribution of platinum group elements (Pt, Pd, Rh) in environmental and clinical matrices: Composition, analytical techniques and scientific outlook - Status report [J].
Hees, T ;
Wenclawiak, B ;
Lustig, S ;
Schramel, P ;
Schwarzer, M ;
Schuster, M ;
Verstraete, D ;
Dams, R ;
Helmers, E .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 1998, 5 (02) :105-111
[10]  
Heinrich E, 1996, FRESEN J ANAL CHEM, V354, P883