Does digital deconvolution improve two-photon microscopy in deep tissue imaging?

被引:0
|
作者
Noakes, C [1 ]
Goto, T [1 ]
Keller, R [1 ]
Periasamy, A [1 ]
机构
[1] Univ Virginia, WM Keck Ctr Cellular Imaging, Charlottesville, VA 22903 USA
关键词
multiphoton microscopy; digital deconvolution; deep tissue imaging; frog embryo; explant;
D O I
10.1117/12.424581
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the past scientists have had difficulties visualizing cellular processes in thick tissue specimens. With conventional imaging techniques, fluorescence signals from above and below the focal plane create background noise that significantly degrades the resultant images. Today we have two-photon excitation microscopy, which surpasses other imaging systems in its ability to see further and more clearly into thick tissue. The two-photon system has an infrared pulsed laser light illumination that hits only at the focal plane, thus reducing autofluorescence and photobleaching. Although this technique is superior to others in fluorescence imaging, the two-photon images can still have a considerable amount of background glow deep down in the tissue. Due to this problem, we propose that digital deconvolution be used to improve these signals by eliminating the background noise in the two-photon images. The purpose of deconvolution is to undo the degradation of the image that was created by convolution. Deconvolution uses the entire fluorescent signal and digitally reverses it through the use of a point spread function. We have developed a model system for measuring the depth penetration of our two-photon system integrated with the Biorad MRC 600. With this system the deconvolved signal at different depths shows a better signal-to-noise (S/N) of the two-photon images than those without deconvolution. The biological applications of this process will be discussed in this paper.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 50 条
  • [1] Applications of two-photon fluorescence microscopy in deep tissue imaging
    Dong, CY
    Yu, B
    Hsu, L
    Kaplan, P
    Blankschstein, D
    Langer, R
    So, PTC
    OPTICAL SENSING, IMAGING, AND MANIPULATION FOR BIOLOGICAL AND BIOMEDICAL APPLICATIONS, 2000, 4082 : 105 - 114
  • [2] Deep tissue two-photon microscopy
    Helmchen, F
    Denk, W
    NATURE METHODS, 2005, 2 (12) : 932 - 940
  • [3] Deep tissue two-photon microscopy
    Fritjof Helmchen
    Winfried Denk
    Nature Methods, 2005, 2 : 932 - 940
  • [4] Innovations in two-photon deep tissue microscopy
    Buehler, C
    Kim, KH
    Dong, CY
    Masters, BR
    So, PTC
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1999, 18 (05): : 23 - 30
  • [5] Innovations in two-photon deep tissue microscopy
    Buehler, Christof
    Kim, Ki Hean
    Dong, Chen Y.
    Masters, Barry R.
    So, Peter T.c.
    IEEE Engineering in Medicine and Biology Magazine, 18 (05): : 23 - 30
  • [6] Improving two-photon deep tissue imaging with blind maximum-likelihood deconvolution
    Hsu, L
    So, PTC
    Dong, CY
    BIOPHYSICAL JOURNAL, 1999, 76 (01) : A98 - A98
  • [7] Advantages of Non-degenerate Two-photon Microscopy for Deep Tissue Imaging
    Sadegh, Sanaz
    Yang, Mu-Han
    Ferri, Christopher
    Thunemann, Martin
    Devor, Anna
    Fainman, Yeshaiahu
    BIOPHYSICAL JOURNAL, 2020, 118 (03) : 311A - 311A
  • [8] Deep insights: intravital imaging with two-photon microscopy
    Ina Maria Schießl
    Hayo Castrop
    Pflügers Archiv - European Journal of Physiology, 2016, 468 : 1505 - 1516
  • [9] Deep insights: intravital imaging with two-photon microscopy
    Schiessl, Ina Maria
    Castrop, Hayo
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2016, 468 (09): : 1505 - 1516
  • [10] An evaluation of two-photon excitation versus confocal and digital deconvolution fluorescence microscopy imaging in Xenopus morphogenesis
    Periasamy, A
    Skoglund, P
    Noakes, C
    Keller, R
    MICROSCOPY RESEARCH AND TECHNIQUE, 1999, 47 (03) : 172 - 181