Response Reduction of Secondary Piping Systems in Base-isolated Buildings

被引:0
作者
Kamble, Vishal [1 ]
Bhaiya, Vishisht [2 ]
Bharti, Shiv Dayal [3 ]
Shrimali, Mahendra Kumar [3 ]
Datta, Tushar Kanti [3 ]
机构
[1] Malaviya Natl Inst Technol MNIT, Natl Ctr Disaster Mitigat & Management NCDMM, Jaipur, Rajasthan, India
[2] Sardar Vallabhbhai Natl Inst Techn, Dept Civil Engn, Surat, India
[3] MNIT, NCDMM, Jaipur, Rajasthan, India
关键词
Primary-secondary system; Bi-directional earthquake; Base isolation; Nonlinear time history analysis; Absolute acceleration; NUCLEAR-POWER-PLANTS; SEISMIC RESPONSE; EQUIPMENT; SUPPORT;
D O I
10.1007/s40996-021-00771-z
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The seismic response reduction of a multi-supported secondary system (SS) attached to a base-isolated six-storied building is evaluated for different types of earthquakes. For this purpose, two 3D models of a six-storied building are taken for the analysis; one is fixed base and the other is base isolated. Lead rubber isolator is used for the isolation. Both buildings support a secondary system (SS), which is a fluid pipe running along with the height on one side of the building (PS). Both buildings are analysed under the bi-directional earthquake ground motions with different ratios of ground acceleration in two directions. Considering the full interaction between the PS and SS, the nonlinear time history analysis is carried out in SAP 2000 to obtain different response quantities of interest at different levels of the PGA. The efficiency of the base isolation in reducing the responses of the SS is investigated by comparing the responses between the SS mounted base-isolated and fixed-base buildings. The responses include the maximum absolute acceleration, maximum relative displacement, maximum stresses developed at the critical sections of the pipe and maximum storey drift. In addition, the difference between the floor response spectra of the two primary systems is investigated. Results of the numerical study indicate that the use of base isolation system in the PS provides considerable protection to the SS. It reduces the peak stresses of the SS at critical sections by about 60-70%.
引用
收藏
页码:3319 / 3336
页数:18
相关论文
共 31 条
[21]  
Malushte S.R., 2005, Proceedings: 18th International Conference on Structural Mechanics in Reactor Technology (SMiRT 18), P3404
[22]  
Pardalopoulos SIPJ, 2014, EARTHQ ENG STRUCT D, V41, P1549, DOI [10.1002/eqe, DOI 10.1002/EQE]
[23]  
Pavlou E.A., 2005, Performance of Primary and Secondary Systems in Buildings with Seismic Protective Systems
[24]  
PEER, 2020, PEER GROUND MOT DAT
[25]   Performance of sliding systems under near-fault motions [J].
Rao, PB ;
Jangid, RS .
NUCLEAR ENGINEERING AND DESIGN, 2001, 203 (2-3) :259-272
[26]   The influence of earthquake vertical component on the seismic response of masonry structures [J].
Rinaldin, Giovanni ;
Fasan, Marco ;
Noe, Salvatore ;
Amadio, Claudio .
ENGINEERING STRUCTURES, 2019, 185 :184-193
[27]   Seismic response of base isolated nuclear power plants considering impact to moat walls [J].
Sarebanha, A. ;
Mosqueda, G. ;
Kim, M. K. ;
Kim, J. H. .
NUCLEAR ENGINEERING AND DESIGN, 2018, 328 :58-72
[28]   Seismic response of submerged secondary systems in base-isolated structures [J].
Shin, TM ;
Kim, KJ .
ENGINEERING STRUCTURES, 1997, 19 (06) :452-464
[29]   NON-CLASSICAL DAMPING IN DYNAMIC ANALYSIS OF BASE-ISOLATED STRUCTURES WITH INTERNAL EQUIPMENT [J].
TSAI, HC ;
KELLY, JM .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1988, 16 (01) :29-43
[30]   SEISMIC RESPONSE OF THE SUPERSTRUCTURE AND ATTACHED EQUIPMENT IN A BASE-ISOLATED BUILDING [J].
TSAI, HC ;
KELLY, JM .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1989, 18 (04) :551-564