Fetal Heart Rate Detection Algorithm from Noninvasive Fetal Electrocardiogram

被引:0
作者
Nadila, Hasna [1 ]
Danudirdjo, Donny [1 ]
Zakaria, Hasballah [1 ]
机构
[1] Bandung Inst Technol, Elect & Informat Engn, Bandung, Indonesia
来源
2021 IEEE INTERNATIONAL BIOMEDICAL INSTRUMENTATION AND TECHNOLOGY CONFERENCE (IBITEC): THE IMPROVEMENT OF HEALTHCARE TECHNOLOGY TO ACHIEVE UNIVERSAL HEALTH COVERAGE | 2021年
关键词
NIFECG; FHR; TS; SNR; FQRS detection; QRS DETECTION; RATE EXTRACTION; ECG; COMBINATION;
D O I
10.1109/IBITeC53045.2021.9649332
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Noninvasive fetal electrocardiogram (NIFECG) has the potential to measure fetal heart rate (FHR). However, it has low signal-to-noise ratio (SNR) because of many interferences, mainly from the mother's biosignal. The algorithm to measure FHR from NIFECG generally consists of three steps, i.e. preprocessing, FECG extraction, and fetal QRS (FQRS) detection. One of the methods to extract FECG is template subtraction (TS), which does not require many channels. Nevertheless, it cannot significantly enhance the SNR. While for the QRS detection, the Pan-Tompkins algorithm is frequently used but initially designed for the adult ECG. Other than low SNR, NIFECG also faces a problem related to the standard configuration. It is still unknown where the electrodes placement can produce optimal FECG signal quality. Hence, this study aimed to increase FHR accuracy by developing an algorithm based on template subtraction and modified Pan-Tompkins. This study also proposed a channel selection process to eliminate low SNR channels interfering with FHR detection. Another objective was to analyze the electrode placement of NIFECG that has an optimal FECG quality based on its SNR value. The results showed that the proposed algorithm could produce mean absolute error (MAE) of 1.68 ms and mean square error (MSE) of 8.04 bpm2. Increasing the SNR threshold for channel selection could decrease MAE and MSE to 1.00 ms and 1.11 bpm2. Electrodes placement analysis from the Matonia dataset configuration showed that channel three has the highest SNR FECG value (20.18 dB) compared to the other channels.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [31] Application of spatio-temporal filtering to fetal electrocardiogram enhancement
    Kotas, M.
    Jezewski, J.
    Horoba, K.
    Matonia, A.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2011, 104 (01) : 1 - 9
  • [32] Advancing Fetal Heart Rate Monitoring: AI-Based Approach for Baseline Detection and Classification
    Alashbi, Abdulaziz
    Mansor, Adzmely
    Mohamed, Abdul Hakim H. M.
    Shayea, Ibraheem
    El-Saleh, Ayman A.
    11TH INTERNATIONAL CONFERENCE ON WIRELESS NETWORKS AND MOBILE COMMUNICATIONS, WINCOM 2024, 2024, : 617 - 621
  • [33] Deceleration area of fetal heart rate trace and fetal acidemia at delivery: A case-control study
    Giannubilo, Stefano Raffaele
    Buscicchio, Giorgia
    Gentilucci, Lucia
    Palla, Gian Paolo
    Tranquilli, Andrea Luigi
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2007, 20 (02) : 141 - 144
  • [34] Fetal motion estimation from noninvasive cardiac signal recordings
    Biglari, Hadis
    Sameni, Reza
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (11) : 2003 - 2023
  • [35] Design of an FECG scalp electrode fetal heart rate monitor
    Reguig, FB
    Kirk, DL
    MEDICAL ENGINEERING & PHYSICS, 1996, 18 (02) : 150 - 160
  • [36] Isolated spontaneous fetal heart rate decelerations: prognostic significance
    Gioia, S
    Piazze, JJ
    Maranghi, L
    Anceschi, M
    JOURNAL OF PERINATAL MEDICINE, 2006, 34 (01) : 86 - 87
  • [37] Estimation and Discriminability of Doppler Ultrasound Fetal Heart Rate Variability Measures
    Vargas-Calixto, Johann
    Warrick, Philip
    Kearney, Robert
    FRONTIERS IN ARTIFICIAL INTELLIGENCE, 2021, 4
  • [38] CTGGAN: Reliable Fetal Heart Rate Signal Generation Using GANs
    Yu, Zichang
    Hu, Yating
    Lu, Yu
    Li, Leya
    Ge, Huilin
    Fu, Xianghua
    2024 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS, IJCNN 2024, 2024,
  • [39] Standardization of fetal heart rate pattern management: Is international consensus possible?
    Parer, Julian T.
    HYPERTENSION RESEARCH IN PREGNANCY, 2014, 2 (02) : 51 - 58
  • [40] Monitoring of fetal heart rate using sharp transition FIR filter
    Marchon, Niyan
    Naik, Gourish
    Pai, Radhakrishna
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 44 : 191 - 199