Column-Parallel Correlated Multiple Sampling Circuits for CMOS Image Sensors and Their Noise Reduction Effects

被引:57
作者
Suh, Sungho [1 ]
Itoh, Shinya [1 ]
Aoyama, Satoshi [2 ]
Kawahito, Shoji [1 ]
机构
[1] Shizuoka Univ, Res Inst, Shizuoka, Japan
[2] Brookman Technol Inc, Shizuoka, Japan
关键词
CMOS image sensor; low noise; wide dynamic range; column-parallel correlated multiple sampling; folding integration technique; GAIN;
D O I
10.3390/s101009139
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For low-noise complementary metal-oxide-semiconductor (CMOS) image sensors, the reduction of pixel source follower noises is becoming very important. Column-parallel high-gain readout circuits are useful for low-noise CMOS image sensors. This paper presents column-parallel high-gain signal readout circuits, correlated multiple sampling (CMS) circuits and their noise reduction effects. In the CMS, the gain of the noise cancelling is controlled by the number of samplings. It has a similar effect to that of an amplified CDS for the thermal noise but is a little more effective for 1/f and RTS noises. Two types of the CMS with simple integration and folding integration are proposed. In the folding integration, the output signal swing is suppressed by a negative feedback using a comparator and one-bit D-to-A converter. The CMS circuit using the folding integration technique allows to realize a very low-noise level while maintaining a wide dynamic range. The noise reduction effects of their circuits have been investigated with a noise analysis and an implementation of a 1Mpixel pinned photodiode CMOS image sensor. Using 16 samplings, dynamic range of 59.4 dB and noise level of 1.9 e(-) for the simple integration CMS and 75 dB and 2.2 e(-) for the folding integration CMS, respectively, are obtained.
引用
收藏
页码:9139 / 9154
页数:16
相关论文
共 12 条
[1]   Review of CMOS image sensors [J].
Bigas, M ;
Cabruja, E ;
Forest, J ;
Salvi, J .
MICROELECTRONICS JOURNAL, 2006, 37 (05) :433-451
[2]  
FINDLATER K, 2004, P SOC PHOTO-OPT INS, V525, P187
[3]  
Hopkinson G. R., 1982, J PHYS E, V15, P1215
[4]  
Kawahito S, 2003, ISSCC DIG TECH PAP I, V46, P224
[5]   Noise analysis of high-gain, low-noise column readout circuits for CMOS image sensors [J].
Kawai, N ;
Kawahito, S .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2004, 51 (02) :185-194
[6]   Effectiveness of a correlated multiple sampling differential averager for reducing 1/f noise [J].
Kawai, Nobuhiro ;
Kawahito, Shoji .
IEICE ELECTRONICS EXPRESS, 2005, 2 (13) :379-383
[7]  
Krymski A., 2003, P IEEE WORKSH CCD AD
[8]  
Lee P.P.K., 1995, P IEEE WORKSH CCD AD
[9]  
Nakamura J., 2006, IMAGE SENSORS SIGNAL, P144
[10]   A High-Speed Low-Noise CMOS Image Sensor With 13-b Column-Parallel Single-Ended Cyclic ADCs [J].
Park, Jong-Ho ;
Aoyama, Satoshi ;
Watanabe, Takashi ;
Isobe, Keigo ;
Kawahito, Shoji .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2009, 56 (11) :2414-2422