K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors

被引:475
作者
Roessl, E. [1 ]
Proksa, R. [1 ]
机构
[1] Philips Res Europe, Sect Med Imaging Syst, Hamburg, Germany
关键词
D O I
10.1088/0031-9155/52/15/020
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
After passage through matter, the energy spectrum of a polychromatic beam of x-rays contains valuable information about the elemental composition of the absorber. Conventional x-ray systems or x-ray computed tomography (CT) systems, equipped with scintillator detectors operated in the integrating mode, are largely insensitive to this type of spectral information, since the detector output is proportional to the energy fluence integrated over the whole spectrum. The main purpose of this paper is to investigate to which extent energysensitive photon counting devices, operated in the pulse-mode, are capable of revealing quantitative information about the elemental composition of the absorber. We focus on the detection of element-specific, K-edge discontinuities of the photo-electric cross-section. To be specific, we address the question of measuring and imaging the local density of a gadolinium-based contrast agent, in the framework of a generalized dual-energy pre-processing. Our results are very promising and seem to open up new possibilities for the imaging of the distribution of elements with a high atomic number Z in the human body using x-ray attenuation measurements. To demonstrate the usefulness of the detection and the appropriate processing of the spectral information, we present simulated images of an artherosclerotic coronary vessel filled with gadolinium-based contrast agent. While conventional systems, equipped with integrating detectors, often fail to differentiate between contrast filled lumen and artherosclerotic plaque, the use of an energy-selective detection system based on the counting of individual photons reveals a strong contrast between plaque and contrast agent.
引用
收藏
页码:4679 / 4696
页数:18
相关论文
共 32 条
[1]   Comparison of dual energy detector system performance [J].
Alvarez, RE ;
Seibert, JA ;
Thompson, SK .
MEDICAL PHYSICS, 2004, 31 (03) :556-565
[2]   Active energy selective image detector for dual-energy computed radiography [J].
Alvarez, RE .
MEDICAL PHYSICS, 1996, 23 (10) :1739-1748
[3]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[4]   DETECTOR FOR DUAL-ENERGY DIGITAL RADIOGRAPHY [J].
BARNES, GT ;
SONES, RA ;
TESIC, MM ;
MORGAN, DR ;
SANDERS, JN .
RADIOLOGY, 1985, 156 (02) :537-540
[5]  
Berger M., 1999, XCOM PHOTON CROSS SE
[6]   DUAL-ENERGY PROJECTION RADIOGRAPHY - INITIAL CLINICAL-EXPERIENCE [J].
BRODY, WR ;
CASSEL, DM ;
SOMMER, FG ;
LEHMANN, LA ;
MACOVSKI, A ;
ALVAREZ, RE ;
PELC, NJ ;
RIEDERER, SJ ;
HALL, AL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (02) :201-205
[7]   A pixel detector for the protein crystallography beamline at the SLS [J].
Brönnimann, C ;
Baur, R ;
Eikenberry, EF ;
Fischer, P ;
Florin, S ;
Horisberger, R ;
Lindner, M ;
Schmitt, B ;
Schulze, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3) :531-535
[8]  
BROOKS RA, 1978, RADIOLOGY, V126, P255
[9]   A readout chip for a 64 x 64 pixel matrix with 15-bit single Photon Counting [J].
Campbell, M ;
Heijne, EHM ;
Meddeler, G ;
Pernigotti, E ;
Snoeys, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :751-753
[10]  
Chmeissani M., 2004, Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510), P787, DOI 10.1109/IMTC.2004.1351164