A Multicommuted Flow Procedure for the Determination of Total and Free Cholesterol in Eggs and Human Blood Serum by Chemiluminescence

被引:4
作者
Leite, Oldair D. [4 ]
Vieira, Heberth J. [3 ]
Fatibello-Filho, Orlando [2 ]
Rocha, Fabio R. P. [1 ]
机构
[1] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
[2] Univ Fed Sao Carlos, Dept Quim, BR-13560970 Sao Carlos, SP, Brazil
[3] Univ Fed Pampa, BR-96412420 Bage, RS, Brazil
[4] Univ Fed Bahia, Inst Ciencias Ambientais & Desenvolvimento Susten, BR-47805100 Barreiras, BA, Brazil
关键词
flow analysis; multicommutation; chemiluminescence; cholesterol; cholesterol esterase; cholesterol oxidase; INJECTION ANALYSIS; ENZYMATIC ASSAY; SYSTEM; OXIDASE; BIOSENSOR; ELECTRODE; ESTERASE; SENSOR;
D O I
10.1590/S0103-50532010000900017
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A multicommuted flow-based procedure with detection by chemiluminescence for the determination of total and free cholesterol without changes in the flow manifold is proposed. Cholesterol esterase and cholesterol oxidase were both immobilized on glass beads via glutaraldehyde/(3-aminopropyl)-triethoxysilane and mini-columns containing the enzymes were used for online sample treatment. Cholesterol esters were cleaved to cholesterol and fatty acids at the packed reactor containing cholesterol esterase. The reactor containing cholesterol oxidase converted cholesterol to cholest-4-en-3-one also yielding hydrogen peroxide. Detection was based on the chemiluminescence produced by H(2)O(2) in the hexacyanoferrate(III)-luminol system. Influence of both chemical and hydrodynamic variables on the chemiluminescence signals were investigated. The analytical curves were linear from 250 to 2500 mg L(-1) and from 500 to 4000 mg L(-1), for free and total cholesterol, respectively. Detection limits for both analytes were estimated as 60 mg L(-1) at 99.7% confidence level. The sampling rate was 55 h(-1) and reagent consumption was 350 mg of luminol and 2.6 mg of potassium hexacyanoferrate(III) per determination. The procedure developed was successfully applied for determination of cholesterol in eggs and in human blood serum with results in agreement with the reference spectrophotometric method at the 95% confidence level.
引用
收藏
页码:1710 / 1717
页数:8
相关论文
共 30 条
  • [1] Development of organic phase amperometric biosensor for measuring cholesterol in food samples
    Adányi, N
    Váradi, M
    [J]. EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2003, 218 (01) : 99 - 104
  • [2] Fluorometric method for the enzymatic determination of cholesterol
    Amundson, DM
    Zhou, MJ
    [J]. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1999, 38 (01): : 43 - 52
  • [3] MULTICOMMUTATION IN FLOW-ANALYSIS .3. SPECTROPHOTOMETRIC KINETIC DETERMINATION OF CREATININE IN URINE EXPLOITING A NOVEL ZONE SAMPLING APPROACH
    ARAUJO, AN
    LIMA, JLFC
    REIS, BF
    ZAGATTO, EAG
    [J]. ANALYTICA CHIMICA ACTA, 1995, 310 (03) : 447 - 452
  • [4] Monosegmented flow-analysis of serum cholesterol
    Araújo, AN
    Catita, JAM
    Lima, JLFC
    [J]. FARMACO, 1999, 54 (1-2): : 51 - 55
  • [5] Bishop M., 2005, Clinical Chemistry Principles, Procedures, Correlations, V5th
  • [6] ASSESSMENT OF METHODOLOGIES FOR COLORIMETRIC CHOLESTEROL ASSAY OF MEATS
    BOHAC, CE
    RHEE, KS
    CROSS, HR
    ONO, K
    [J]. JOURNAL OF FOOD SCIENCE, 1988, 53 (06) : 1642 - &
  • [7] Development of a low cost device for chemiluminescence measurements
    Borges, EP
    Fernandes, EN
    Rocha, FRP
    Reis, BF
    [J]. QUIMICA NOVA, 2002, 25 (6B): : 1191 - 1193
  • [8] The National Cholesterol Education Program - Progress and prospects
    Cleeman, JI
    Lenfant, C
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 280 (24): : 2099 - 2104
  • [10] Determination of free cholesterol based on a novel flow-injection chemiluminescence method by immobilizing enzyme
    Hu, Yufei
    Zhang, Zhujun
    [J]. LUMINESCENCE, 2008, 23 (05) : 338 - 343