Assessment of right ventricular function by 16-detector-row CT: comparison with magnetic resonance imaging

被引:88
作者
Koch, K [1 ]
Oellig, F
Oberholzer, K
Bender, P
Kunz, P
Mildenberger, P
Hake, U
Kreitner, KF
Thelen, M
机构
[1] Univ Mainz, Dept Radiol, D-55131 Mainz, Germany
[2] Univ Mainz, Dept Cardiothorac & Vasc Surg, D-55131 Mainz, Germany
关键词
heart; CT; multidetector-row; function; ventricles; MRI;
D O I
10.1007/s00330-004-2543-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to determine right ventricular (RV) function from 16-detector-row CT by using two different software tools in comparison with MRI. Nineteen patients underwent cardiac CT. (1) With semiautomated contour detection software end-diastolic and end-systolic RV volumes were determined from short-axis CT reformations (MPR) created at every 10% of the RR-interval. (2) End-systolic and end-diastolic axial images were transformed to 3D to determine the volumes by using a threshold-supported reconstruction algorithm. Steady-state free-precession cine-MRI of the heart was done in short-axis orientation. RV function could not be analyzed in one patient because of sternal wire artifacts in MRI. Mean end-diastolic (155.4 +/- 54.6 ml) and end-systolic (79.1 +/- 37.0 ml) RV volumes determined with MPR correlated well with MRI [151.9 +/- 53.7 ml (r=0.98) and 75.0 +/- 36.0 ml (r=0.96), respectively (P<0.001)]. RV stroke volume (76.2 +/- 20.2 ml for MPR-CT, 76.9 +/- 20.7 ml for MRI, r=0.93) showed a good correlation and RV ejection fraction (50.8 +/- 8.4% for MPR-CT, 51.9 +/- 7.4% for MRI,)-=0.74) only a moderate one. Threshold supported 3D reconstructions revealed insufficient correlations with MRI (r=0.31-0.59). MPR-based semiautomated analysis of cardiac 16 detector-row CT allows for RV functional analysis. The results correlate well with MRI findings. Threshold value-supported 3D reconstructions did not show satisfying results because of inhomogenelties of RV contrast enhancement.
引用
收藏
页码:312 / 318
页数:7
相关论文
共 25 条
[1]   Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging [J].
Alfakih, K ;
Plein, S ;
Bloomer, T ;
Jones, T ;
Ridgway, J ;
Sivananthan, M .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (01) :25-32
[2]   Detection of coronary artery stenoses with multislice helical CT angiography [J].
Becker, CR ;
Knez, A ;
Leber, A ;
Treede, H ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (05) :750-755
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
Blobel J, 2003, ROFO-FORTSCHR RONTG, V175, P1264
[5]   Time-effectiveness, observer-dependence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT [J].
Boehm, T ;
Alkadhi, H ;
Roffi, M ;
Willmann, JK ;
Desbiolles, LM ;
Marincek, B ;
Wildermuth, S .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04) :529-537
[6]   Pulmonary embolism findings on chest radiographs and multislice spiral CT [J].
Coche, E ;
Verschuren, F ;
Hainaut, P ;
Goncette, L .
EUROPEAN RADIOLOGY, 2004, 14 (07) :1241-1248
[7]   Severity assessment of acute pulmonary embolism: evaluation using helical CT [J].
Collomb, D ;
Paramelle, PJ ;
Calaque, O ;
Bosson, JL ;
Vanzetto, G ;
Barnoud, D ;
Pison, C ;
Coulomb, M ;
Ferretti, G .
EUROPEAN RADIOLOGY, 2003, 13 (07) :1508-1514
[8]   Coronary artery disease: new insights and their implications for radiology [J].
Dewey, M ;
Borges, AC ;
Kivelitz, D ;
Taupitz, M ;
Wagner, S ;
Baumann, G ;
Hamm, B .
EUROPEAN RADIOLOGY, 2004, 14 (06) :1048-1054
[9]  
DORGELO J, 2003, IMAGING DECISIONS, V7, P9
[10]   Multi-slice CT (MSCT) in cardiac function imaging: Threshold-value-supported 3D volume reconstructions to determine the left ventricular ejection fraction in comparison to MRI [J].
Ehrhard, K ;
Oberholzer, K ;
Gast, K ;
Mildenberger, P ;
Kreitner, KF ;
Thelen, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (12) :1566-1569