Effects of surface treatments on high cycle corrosion fatigue of metallic implant materials

被引:71
|
作者
Papakyriacou, M
Mayer, H
Pypen, C
Plenk, H
Stanzl-Tschegg, S
机构
[1] Univ Agr Sci, Inst Met & Phys, A-1180 Vienna, Austria
[2] Univ Vienna, Inst Histol & Embryol, A-1090 Vienna, Austria
[3] Univ Vienna, Dent Clin, Dept Oral Surg, Vienna, Austria
[4] Catholic Univ Louvain, Dept Met & Mat Engn, B-3000 Louvain, Belgium
基金
奥地利科学基金会;
关键词
c.p; Niobium; Tantalum; Titanium; Ti-6Al-7Nb alloy; high cycle corrosion fatigue; embrittlement; dental implants;
D O I
10.1016/S0142-1123(00)00057-8
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Long term corrosion fatigue properties of two materials which are candidates for skeletal implants - cold worked c.p. Niobium and c.p. Tantalum - have been investigated. Fatigue properties have been compared to two implant materials in clinical use c.p. Titanium and Ti-6Al-7Nb alloy. Constant amplitude fatigue experiments (S-N curves) were performed at ultrasonic frequency (20 kHz) with two different surface structures (ground surface and blasted and shot peened surface) in ambient air and in a corrosive fluid similar to the body fluid in the oral cavity. The endurance limit at 2x10(8) cycles of all materials decreased by 5-20% if they were cycled in corrosive fluid instead of ambient air. The loss of fatigue strength is more pronounced for ground Ti-6Al-7Nb alloy and c.p. Ti than for ground c.p. Nb cw and c.p. Ta cw. Fracture surfaces show a more pronounced embrittlement of ground Ti-6Al-7Nb alloy and c.p, Titanium after cycling in corrosive fluid than ground c.p. Tantalum and c.p. Niobium. A beneficial influence of surface structuring by blasting and shot peening on the fatigue properties was found for all materials in both environments. Fatigue loading using ultrasonic frequency allows one to select appropriate implant materials and to determine their very-high cycle corrosion-fatigue behaviour within reasonable testing times. Though the obtained high-frequency values may not be fully representative of actual in vivo behaviour, they are regarded as useful material characterizing values. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:873 / 886
页数:14
相关论文
共 34 条
  • [31] Effects of 100 ppb dissolved oxygen on low-cycle fatigue behaviors of 316LN austenitic stainless steel in borated and lithiated high temperature water and mechanism behind these effects
    Xiong, Yida
    Watanabe, Yutaka
    Shibayama, Yuki
    Mary, Nicolas
    CORROSION SCIENCE, 2020, 168
  • [32] A novel strategy for estimating the diffusion behavior of hydrogen in metallic materials with the combined effect of stress corrosion and hydrogenation: Case study of 2.25Cr-1Mo-0.25V high-strength steel
    Yin, Changdong
    Wu, Yiwen
    Xu, Zhou
    Ye, Dongdong
    Yao, Jun
    Chen, Jianjun
    Liu, Qiang
    Ge, Xin
    Ding, Meiling
    VACUUM, 2024, 219
  • [33] MWCNT reinforced bone like calcium phosphate-Hydroxyapatite composite coating developed through pulsed electrodeposition with varying amount of apatite phase and crystallinity to promote superior osteoconduction, cytocompatibility and corrosion protection performance compared to bare metallic implant surface
    Chakraborty, Rajib
    Seesala, Venkata S.
    Sen, Mainak
    Sengupta, Srijan
    Dhara, Santanu
    Saha, Partha
    Das, Karabi
    Das, Siddhartha
    SURFACE & COATINGS TECHNOLOGY, 2017, 325 : 496 - 514
  • [34] Low-cycle fatigue behaviors of 316L austenitic stainless steels with different surface finishing in simulated pressurized water reactor primary water and an oxygenated, borated, lithiated high temperature water
    Xiong, Yida
    Watanabe, Yutaka
    Shibayama, Yuki
    Zhong, Xiangyu
    Mary, Nicolas
    CORROSION SCIENCE, 2021, 190