Structural analysis for an upper port of the ITER vacuum vessel

被引:4
作者
Hong, Y. S. [1 ]
Kwon, T. H. [1 ]
Ahn, H. J. [1 ]
Kim, Y. K. [1 ]
Lee, C. D. [1 ]
机构
[1] Hyundai Heavy Ind Co Ltd, Elect Mech Res Inst, Yongin 446716, South Korea
关键词
International thermonuclear experimental reactor (ITER); upper port flange; port plug;
D O I
10.1016/j.fusengdes.2007.05.058
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The international thermonuclear experimental reactor (ITER) vacuum vessel (VV) upper port has a trapezoidal/rectangular cross-section and consists of a port stub, a stub extension and a port extension with a connecting duct. To investigate the structural integrity and to increase the structural reliability of the VV and ports, the structural analyses of the upper port structure have been performed. Two advanced designs from the ITER international team have been deeply analyzed. To verify the strength of the reinforcing ribs for the connecting duct and of the fastening/sealing units, the local analyses utilizing the sub-modeling technique have been performed. The upper port flange based on the original design could withstand design loads, but the flange surface could be detached under the design condition. The advanced design using large superbolts is highly acceptable in the structural design point of view. The deflection of the plug for the other advanced design with a removable flange is relatively large since the stiffness of a port and a plug is reduced by the nut groove and the removable flange. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1969 / 1976
页数:8
相关论文
共 7 条
  • [1] AHN HJ, 2006, 24 S FUS TECHN WARS
  • [2] *ITER, 2004, 15040507 G74 MA
  • [3] *ITER, 2003, MD157030513 G15
  • [4] *ITER, 2004, 1040507R01 G15 MA
  • [5] *ITER, 2004, G15 DDD
  • [6] *ITER, 2003, 256030423W01 G15 MD
  • [7] SANNAZZARO G, 2005, MECH LOADING CONDITI